Your browser doesn't support javascript.
loading
Effect of mechanical ventilation under intubation on respiratory tract change of bacterial count and alteration of bacterial flora.
Xue-Meng, Chen; Gao-Wang, Liu; Xiao-Mei, Ling; Fan-Fang, Zeng; Jin-Fang, Xiao.
Afiliação
  • Xue-Meng C; Department of Anesthesiology, Deyang People's Hospital, Deyang, Sichuan, China.
  • Gao-Wang L; Department of Anesthesiology, Nanfang Hospital, Southern Medical University, Guangzhou, Guangdong, China.
  • Xiao-Mei L; Department of Anesthesiology, Nanfang Hospital, Southern Medical University, Guangzhou, Guangdong, China.
  • Fan-Fang Z; Department of Anesthesiology, Guangdong Provincial People's Hospital, Guangdong Academy of Medical Sciences, Guangzhou, Guangdong, China.
  • Jin-Fang X; Department of Anesthesiology, Shenzhen Maternity and Child Healthcare Hospital, Southern Medical University, Guangzhou, Guangdong, China.
Exp Lung Res ; 49(1): 165-177, 2023.
Article em En | MEDLINE | ID: mdl-37789686
ABSTRACT

Background:

The most common 'second strike' in mechanically ventilated patients is a pulmonary infection caused by the ease with which bacteria can invade and colonize the lungs due to mechanical ventilation. At the same time, metastasis of lower airway microbiota may have significant implications in developing intubation mechanical ventilation lung inflammation. Thus, we establish a rat model of tracheal intubation with mechanical ventilation and explore the effects of mechanical ventilation on lung injury and microbiological changes in rats. To provide a reference for preventing and treating bacterial flora imbalance and pulmonary infection injury caused by mechanical ventilation of tracheal intubation.

Methods:

Sprague-Dawley rats were randomly divided into Control, Mechanical ventilation under intubation (1, 3, 6 h) groups, and Spontaneously breathing under intubation (1, 3, 6 h). Lung histopathological injury scores were evaluated. 16SrDNA sequencing was performed to explore respiratory microbiota changes, especially, changes of bacterial count and alteration of bacterial flora.

Results:

Compared to groups C and SV, critical pathological changes in pulmonary lesions occurred in the MV group after 6 h (p < 0.05). The Alpha diversity and Beta diversity of lower respiratory tract microbiota in MV6, SV6, and C groups were statistically significant (p < 0.05). The main dominant bacterial phyla in the respiratory tract of rats were Proteobacteria, Firmicutes, Bacteroidetes, and Cyanobacteria. Acinetobacter radioresistens in group C was significant, Megaonas in group MV6 was significantly increased, and Parvibacter in group SV6 was significantly increased. Anaerobic, biofilm formation, and Gram-negative bacteria-related functional genes were altered during mechanical ventilation with endotracheal intubation.

Conclusion:

Mechanical ventilation under intubation may cause dysregulation of lower respiratory microbiota in rats.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Contexto em Saúde: 4_TD Problema de saúde: 4_pneumonia Assunto principal: Pneumonia / Lesão Pulmonar Tipo de estudo: Etiology_studies / Prognostic_studies Limite: Animals / Humans Idioma: En Revista: Exp Lung Res Ano de publicação: 2023 Tipo de documento: Article País de afiliação: China

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Contexto em Saúde: 4_TD Problema de saúde: 4_pneumonia Assunto principal: Pneumonia / Lesão Pulmonar Tipo de estudo: Etiology_studies / Prognostic_studies Limite: Animals / Humans Idioma: En Revista: Exp Lung Res Ano de publicação: 2023 Tipo de documento: Article País de afiliação: China
...