Your browser doesn't support javascript.
loading
Kirigami-Structured, Low-Impedance, and Skin-Conformal Electronics for Long-Term Biopotential Monitoring and Human-Machine Interfaces.
Xia, Meili; Liu, Jianwen; Kim, Beom Jin; Gao, Yongju; Zhou, Yunlong; Zhang, Yongjing; Cao, Duxia; Zhao, Songfang; Li, Yang; Ahn, Jong-Hyun.
Afiliação
  • Xia M; School of Materials Science and Engineering, University of Jinan, Jinan, 250022, China.
  • Liu J; School of Information Science and Engineering, University of Jinan, Jinan, 250022, China.
  • Kim BJ; School of Electrical and Electronic Engineering, Yonsei University, Seoul, 03722, Republic of Korea.
  • Gao Y; Shandong Zhongke Advanced Technology Co., Ltd, Jinan, 250000, China.
  • Zhou Y; School of Materials Science and Engineering, University of Jinan, Jinan, 250022, China.
  • Zhang Y; School of Materials Science and Engineering, University of Jinan, Jinan, 250022, China.
  • Cao D; School of Materials Science and Engineering, University of Jinan, Jinan, 250022, China.
  • Zhao S; School of Materials Science and Engineering, University of Jinan, Jinan, 250022, China.
  • Li Y; School of Information Science and Engineering, University of Jinan, Jinan, 250022, China.
  • Ahn JH; School of Microelectronics, Shandong University, Jinan, 250101, China.
Adv Sci (Weinh) ; 11(1): e2304871, 2024 Jan.
Article em En | MEDLINE | ID: mdl-37984876
ABSTRACT
Epidermal dry electrodes with high skin-compliant stretchability, low bioelectric interfacial impedance, and long-term reliability are crucial for biopotential signal recording and human-machine interaction. However, incorporating these essential characteristics into dry electrodes remains a challenge. Here, a skin-conformal dry electrode is developed by encapsulating kirigami-structured poly(3,4-ethylenedioxythiophene)poly(styrene sulfonate) (PEDOTPSS)/polyvinyl alcohol (PVA)/silver nanowires (Ag NWs) film with ultrathin polyurethane (PU) tape. This Kirigami-structured PEDOTPSS/PVA/Ag NWs/PU epidermal electrode exhibits a low sheet resistance (≈3.9 Ω sq-1 ), large skin-compliant stretchability (>100%), low interfacial impedance (≈27.41 kΩ at 100 Hz and ≈59.76 kΩ at 10 Hz), and sufficient mechanoelectrical stability. This enhanced performance is attributed to the synergistic effects of ionic/electronic current from PEDOTPSS/Ag NWs dual conductive network, Kirigami structure, and unique encapsulation. Compared with the existing dry electrodes or standard gel electrodes, the as-prepared electrodes possess lower interfacial impedance and noise in various conditions (e.g., sweat, wet, and movement), indicating superior water/motion-interference resistance. Moreover, they can acquire high-quality biopotential signals even after water rinsing and ultrasonic cleaning. These outstanding advantages enable the Kirigami-structured PEDOTPSS/PVA/Ag NWs/PU electrodes to effectively monitor human motions in real-time and record epidermal biopotential signals, such as electrocardiogram, electromyogram, and electrooculogram under various conditions, and control external electronics, thereby facilitating human-machine interactions.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Nanofios Limite: Humans Idioma: En Revista: Adv Sci (Weinh) Ano de publicação: 2024 Tipo de documento: Article País de afiliação: China

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Nanofios Limite: Humans Idioma: En Revista: Adv Sci (Weinh) Ano de publicação: 2024 Tipo de documento: Article País de afiliação: China
...