Your browser doesn't support javascript.
loading
Tumor size dependent MNP dose evaluation in realistic breast tumor models for effective magnetic hyperthermia.
Nain, Sandeep; Kumar, Neeraj; Avti, Pramod Kumar.
Afiliação
  • Nain S; Department of Mechanical Engineering, Thapar Institute of Engineering and Technology, Patiala 147004, India; TIET-Virginia Tech Center of Excellence in Emerging Materials, Thapar Institute of Engineering and Technology, Patiala 147004, India.
  • Kumar N; Department of Mechanical Engineering, Thapar Institute of Engineering and Technology, Patiala 147004, India; TIET-Virginia Tech Center of Excellence in Emerging Materials, Thapar Institute of Engineering and Technology, Patiala 147004, India. Electronic address: neerajkumar@thapar.edu.
  • Avti PK; Department of Biophysics, Post Graduate Institute of Medical Education and Research (PGIMER), Chandigarh 160012, India.
Med Eng Phys ; 121: 104065, 2023 11.
Article em En | MEDLINE | ID: mdl-37985024
The goal of the current investigation is to determine the breast tumor size-dependent MNP (Magnetic nano-particle) dose (mg/cm3) that can induce the required therapeutic effects during magnetic nanoparticle hyperthermia (MNH). The investigation is done through the MNH simulations on the tumor models generated from DCE_MRI DICOM images of breast cancer from TCIA ('The Cancer Imaging Archive'). Five tumor models are created from MRI data using 3D slicer software having size range of 3 cm3 to 15 cm3. The FEM-based solver (COMSOL multi-physics) is used to simulate bioheat transfer physics in all five extracted models. Single and multi-point injection strategies have been adopted to induce MNP in tumor tissues. The required MNP dose that may induce necessary therapeutic effects is evaluated by comparing the therapeutic effects produced by constant dose (CD) (5 mg/cm3) and variable reduced dose (RD) (5.5-2.8 mg/cm3) methodologies. Results show that for the requisite therapeutic effects, injected MNP doses (mg/cm3) should not remain constant as the size of the tumor increases. In fact, MNP dose  (mg/cm3) should be reduced as the size of the tumor increases. Results also show that RD works better with a multi-injection strategy than a single injection of MNP. It has been found that the effective MNP dose  (mg/cm3) is reduced by 50 % for the biggest tumor size (15 cm3) using multi-injection MNP delivery with respect to the smallest tumor (3 cm3) selected in this study.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Neoplasias da Mama / Hipertermia Induzida Limite: Female / Humans Idioma: En Revista: Med Eng Phys Assunto da revista: BIOFISICA / ENGENHARIA BIOMEDICA Ano de publicação: 2023 Tipo de documento: Article País de afiliação: Índia

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Neoplasias da Mama / Hipertermia Induzida Limite: Female / Humans Idioma: En Revista: Med Eng Phys Assunto da revista: BIOFISICA / ENGENHARIA BIOMEDICA Ano de publicação: 2023 Tipo de documento: Article País de afiliação: Índia
...