Your browser doesn't support javascript.
loading
Improving the Signal Intensity of Cryosections Using a Conductive Adhesive Film in Matrix-Assisted Laser Desorption/Ionization Mass Spectrometry Imaging.
Saigusa, Daisuke; Saito, Ritsumi; Kawamoto, Komei; Uruno, Akira; Kano, Kuniyuki; Shimma, Shuichi; Aoki, Junken; Yamamoto, Masayuki; Kawamoto, Tadafumi.
Afiliação
  • Saigusa D; Laboratory of Biomedical and Analytical Sciences, Faculty of Pharma-Science, Teikyo University, 2-11-1 Kaga, Itabashi-ku, Tokyo 173-8605, Japan.
  • Saito R; Department of Integrative Genomics, Tohoku Medical Megabank Organization, Tohoku University, 2-1 Seiryo-machi, Aoba-ku, Sendai, Miyagi 980-8573, Japan.
  • Kawamoto K; Advanced Research Center for Innovations in Next-Generation Medicine, Tohoku University, Sendai, Japan.
  • Uruno A; School of Dental Medicine, Tsurumi University, 2-1-3 Tsurumi, Tsurumi-ku, Yokohama, Kanagawa 230-8501, Japan.
  • Kano K; Department of Integrative Genomics, Tohoku Medical Megabank Organization, Tohoku University, 2-1 Seiryo-machi, Aoba-ku, Sendai, Miyagi 980-8573, Japan.
  • Shimma S; Medical Biochemistry, Tohoku University School of Medicine, 2-1 Seiryo-machi, Aoba-ku, Sendai, Miyagi 980-8575, Japan.
  • Aoki J; Department of Health Chemistry, Graduate School of Pharmaceutical Sciences, The University of Tokyo, Tokyo 113-0033, Japan.
  • Yamamoto M; Department of Biotechnology, Graduate School of Engineering, Osaka University, 2-1 Yamada-oka, Suita, Osaka 565-0871, Japan.
  • Kawamoto T; Department of Health Chemistry, Graduate School of Pharmaceutical Sciences, The University of Tokyo, Tokyo 113-0033, Japan.
Mass Spectrom (Tokyo) ; 12(1): A0137, 2023.
Article em En | MEDLINE | ID: mdl-38107656
ABSTRACT
The matrix-assisted laser desorption/ionization mass spectrometry imaging (MALDI-MSI) technique was used to obtain the molecular images of cryosections without labeling. Although MALDI-MSI has been widely used to detect small molecules from biological tissues, issues remain due to the technical process of cryosectioning and limited mass spectrometry parameters. The use of a conductive adhesive film is a unique method to obtain high-quality sections from cutting tissue, such as bone, muscle, adipose tissue, and whole body of mice or fish, and we have reported the utilization of the film for MALDI-MSI in previous. However, some signal of the small molecules using the conductive adhesive films was still lower than on the indium tin oxide (ITO) glass slide. Here, the sample preparation and analytical conditions for MALDI-MSI using an advanced conductive adhesive film were optimized to obtain strong signals from whole mice heads. The effects of tissue thickness and laser ionization power on signal intensity were verified using MALDI-MSI. The phospholipid signal intensity was measured for samples with three tissue thicknesses (5, 10, and 20 µm); compared to the signals from the samples on the ITO glass slides, the signals with conductive adhesive films exhibited significantly higher intensities when a laser with a higher range of power was used to ionize the small molecules. Thus, the technique using the advanced conductive adhesive film showed an improvement in MALDI-MSI analysis.
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Idioma: En Revista: Mass Spectrom (Tokyo) Ano de publicação: 2023 Tipo de documento: Article País de afiliação: Japão

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Idioma: En Revista: Mass Spectrom (Tokyo) Ano de publicação: 2023 Tipo de documento: Article País de afiliação: Japão
...