Your browser doesn't support javascript.
loading
Synthesis of ionically imprinted Poly(Alylthiourea) in the presence of 1-(2-Pyridylazo)-2-Napthol (PAN) for preconcentration in magnetic dispersive solid phase of nickel ions in water and food samples.
Dos Santos, Paula Mantovani; Zanetti Corazza, Marcela; Ricardo Teixeira Tarley, César.
Afiliação
  • Dos Santos PM; Departamento de Química, Universidade Estadual de Londrina, Rod. Celso Garcia Cid, PR 445 Km 380, Campus Universitário, Londrina-PR, CEP 86051-990, Brazil.
  • Zanetti Corazza M; Departamento de Química, Universidade Estadual de Londrina, Rod. Celso Garcia Cid, PR 445 Km 380, Campus Universitário, Londrina-PR, CEP 86051-990, Brazil. Electronic address: corazza@uel.br.
  • Ricardo Teixeira Tarley C; Departamento de Química, Universidade Estadual de Londrina, Rod. Celso Garcia Cid, PR 445 Km 380, Campus Universitário, Londrina-PR, CEP 86051-990, Brazil; Instituto Nacional de Ciência e Tecnologia (INCT) de Bioanalítica, Universidade Estadual de Campinas (UNICAMP), Instituto de Química, Departamento de Química Analítica, Cidade Universitária Zeferino Vaz s/n, CEP 13083-970, Campinas SP, Brazil.
Food Chem ; 440: 138238, 2024 May 15.
Article em En | MEDLINE | ID: mdl-38142556
ABSTRACT
In the present study, a magnetic ion-imprinted polymer based on n-allylthiourea in the presence of 1-(2-pyridylazo)-2-naphthol (MIIP-PAN) was synthesized, characterized, and applied in the preconcentration of nickel ions by dispersive magnetic solid phase extraction (DMSPE) with FAAS detection. For comparison, non-imprinted polymer (MNIP-PAN) and imprinted polymer without PAN were synthesized. The characterization of the polymers was performed by FT-IR, DRX, TEM, TGA, VSM, and BET. Selectivity studies were performed comparing the competitive adsorption of Ni2+ with other cations on MIIP-PAN and MNIP-PAN, achieving higher relative selectivity coefficients for MIIP-PAN than for MNIP-PAN and NIP. Under optimized conditions, the method provided a preconcentration factor of 76.70, detection limit of 0.25 µg/L and intra-day (2.06 - 2.33 %) and inter-day (1.82 - 4.90 %) precision. The developed method was applied to samples of water, teas, and chocolate powder, and its precision was evaluated through tests of recovery and analysis of certified materials.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Propanolaminas / Impressão Molecular / Níquel Idioma: En Revista: Food Chem / Food chem / Food chemistry Ano de publicação: 2024 Tipo de documento: Article País de afiliação: Brasil

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Propanolaminas / Impressão Molecular / Níquel Idioma: En Revista: Food Chem / Food chem / Food chemistry Ano de publicação: 2024 Tipo de documento: Article País de afiliação: Brasil
...