Your browser doesn't support javascript.
loading
Suitability of Slaughterhouse-Acquired Pig Eyes as Model Systems for Refractive Ultraviolet and Infrared Femtosecond Laser Research.
Abdelrahman, Omar; Topka, Marius; Zhang, Yao; Bock, Antonia; Lörner, Johannes; Jungbauer, Rebecca; Hotfiel, Thilo; Paulsen, Friedrich; Hammer, Christian M.
Afiliação
  • Abdelrahman O; Institute of Functional and Clinical Anatomy, Friedrich-Alexander-Universität Erlangen-Nürnberg, Erlangen, Germany.
  • Topka M; Institute of Functional and Clinical Anatomy, Friedrich-Alexander-Universität Erlangen-Nürnberg, Erlangen, Germany.
  • Zhang Y; WaveLight GmbH, Erlangen, Bavaria, Germany.
  • Bock A; WaveLight GmbH, Erlangen, Bavaria, Germany.
  • Lörner J; WaveLight GmbH, Erlangen, Bavaria, Germany.
  • Jungbauer R; Department of Orthodontics, University Medical Centre Regensburg, Regensburg, Germany.
  • Hotfiel T; Center for Musculoskeletal Surgery Osnabrück, Klinikum Osnabrück, Osnabrück, Germany.
  • Paulsen F; Department of Orthopedic and Trauma Surgery, Friedrich-Alexander-Universität Erlangen-Nürnberg, Erlangen, Germany.
  • Hammer CM; Institute of Functional and Clinical Anatomy, Friedrich-Alexander-Universität Erlangen-Nürnberg, Erlangen, Germany.
Curr Eye Res ; 49(4): 401-409, 2024 04.
Article em En | MEDLINE | ID: mdl-38146603
ABSTRACT

PURPOSE:

To elucidate whether it is feasible to use porcine eyes from scalded, abattoir-acquired animals for refractive femtosecond laser research.

METHODS:

An infrared laser (FS 200) and an ultraviolet laser (prototype version) were tested for their applicability on scalded pig eyes. Fifty porcine eyes were divided into two equally-sized groups and assigned to either the infrared or the ultraviolet laser. Both laser groups were comprised of five subgroups of n = 5 eyes each. Group A non-scalded eyes (negative control); group B eyes taken from tunnel-scalded animals; group C1 eyes taken from tank-scalded animals without opaque corneal lesion; group C2 eyes taken from animals with opaque corneal lesion; group D eyes scalded in toto in the laboratory (positive control). In each group the lasers were employed to create a stromal flap. The quality of the laser cuts and the resulting flap beds, as well as of the porcine corneas themselves, was examined by anterior segment optical coherence tomography and scanning electron microscopy.

RESULTS:

All scalded specimens exhibited substantial corneal swelling, most pronounced in group C2. After ultraviolet laser application, the tank- and tunnel-scalded samples displayed marked irregularities and an increased degree of surface roughness in the flap beds. After infrared laser application, this was only the case in the tank-scalded specimens.

CONCLUSION:

It is not recommended to use eyes taken from scalded pigs for ultraviolet femtosecond laser experiments. For infrared femtosecond lasers, eyes taken from tunnel-scalded animals may represent an acceptable alternative, if non-scalded eyes are not available.