Your browser doesn't support javascript.
loading
Dorsal Plating, Lateral Plating, and Intramedullary Screw Fixation of Extra-Articular Proximal Phalangeal Fractures: A Cadaveric Biomechanical Comparison.
Sivakumar, Brahman; Graham, David J; Clarke, Elizabeth.
Afiliação
  • Sivakumar B; Department of Hand and Peripheral Nerve Surgery, Royal North Shore Hospital, St Leonards, NSW, Australia; Australian Research Collaboration on Hands (ARCH), Mudgeeraba, QLD, Australia; Department of Surgery, Faculty of Medicine, the University of Sydney, Camperdown, NSW, Australia.
  • Graham DJ; Australian Research Collaboration on Hands (ARCH), Mudgeeraba, QLD, Australia; Department of Musculoskeletal Services, Gold Coast University Hospital, Southport QLD Australia; Griffith University School of Medicine and Dentistry, Southport, QLD, Australia; Department of Orthopaedic Surgery, Northern Beaches Hospital, Frenchs Forrest, NSW, Australia; Department of Medicine, University of Queensland, Herston, QLD, Australia; Department of Orthopaedic Surgery, Queensland Children's Hospital, South
  • Clarke E; Murray Maxwell Biomechanics Laboratory, Kolling Institute, University of Sydney, Camperdown, NSW Australia.
J Hand Surg Am ; 49(3): 247-252, 2024 Mar.
Article em En | MEDLINE | ID: mdl-38206273
ABSTRACT

PURPOSE:

To provide a biomechanical comparison of dorsal plating, lateral plating and intramedullary screw [IMS] fixation for extra-articular proximal phalangeal fractures.

METHODS:

Midshaft osteotomies were performed on 36 cadaveric proximal phalanges. The phalanges were fixed by dorsal plating, lateral plating or IMS fixation, and subjected to a four-point bending force. Force was applied to achieve displacement of 1 mm/s, until construct failure or to a maximum of 10 mm of displacement. Clinical failure was defined as 2 mm of displacement, and force required to result in 1 mm and 2 mm of displacement was recorded, as was mode of failure.

RESULTS:

Dorsal plating [127.5 N ± 52.6; 46.51-229.17] and lateral plating [77.1 N ± 25.1; 48.3-113.8] required significantly greater force to achieve 1 mm of displacement when compared to IMS [41.2 N ± 12.4; 20.6-62.3]. Dorsal plating [339.2 N ± 91.8; 158.5-538.6] required significantly greater force than lateral plating [154.5 N ± 33.8; 99.0 -204.4] and intramedullary screw fixation [110.0 ± 38.6; 51.1-189.3] to result in 2 mm of displacement. Lateral and dorsal plating constructs failed through plate bending, screw cut-out or plate failure, whilst IMS failed via implant deformity. All three constructs required greater force to result in even 1 mm of displacement than what is likely subjected through rehabilitation via active motion.

CONCLUSIONS:

Lateral plating and IMS fixation offer sufficient stiffness to withstand the likely forces subjected via early active motion without displacement. CLINICAL RELEVANCE Dorsal plating required significantly greater force than lateral plating and intramedullary screw fixation to achieve 1 mm of displacement when used in extra-articular proximal phalangeal fractures in an in vitro setting. However, all three modalities confer enough stability to likely withstand the forces associated with active range of motion.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Fraturas Ósseas Limite: Humans Idioma: En Revista: J Hand Surg Am Ano de publicação: 2024 Tipo de documento: Article País de afiliação: Austrália

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Fraturas Ósseas Limite: Humans Idioma: En Revista: J Hand Surg Am Ano de publicação: 2024 Tipo de documento: Article País de afiliação: Austrália
...