Inverted Placement of Endoscopic One-Way Endobronchial Valve Combined with Gelfoam in the Closure of Bronchopleural Fistula with Empyema in a Mechanically Ventilated Patient: A Case Report.
Respiration
; 103(3): 166-170, 2024.
Article
em En
| MEDLINE
| ID: mdl-38330927
ABSTRACT
Bronchopleural fistula (BPF) with empyema caused by severe necrotizing pulmonary infection is a complicated clinical problem that is often associated with poor general condition so surgical interventions cannot be tolerated in most cases. Here, we present the successful management of multiple BPF with empyema in a mechanically ventilated patient with aspiration lung abscess. Occlusion utilizing Gelfoam followed by endobronchial valves (EBVs) implanted inverted via bronchoscope decreased the air leaking significantly and made intrapleural irrigation for empyema achievable and safe. This is the first report of a novel way of EBV placement and the combination use with other occlusive substances in BPF with empyema in a patient on mechanical ventilation. This method may be an option for refractory BPF cases with pleural infection.