Sensor-Integrated Chairs for Lower Body Strength and Endurance Assessment.
Lee, Alexander W; Lee, Melissa S; Yeh, Daniel P; Yeh, Hsi-Jen J.
Afiliação
  • Lee AW; Chino Premier Surgery Center, Chino, CA 91710, USA.
  • Lee MS; Walnut Valley Research Institute, Walnut, CA 91789, USA.
  • Yeh DP; Walnut Valley Research Institute, Walnut, CA 91789, USA.
  • Yeh HJ; Department of Engineering and Computer Science, Azusa Pacific University, Azusa, CA 91702, USA.
Sensors (Basel) ; 24(3)2024 Jan 25.
Article em En | MEDLINE | ID: mdl-38339505
ABSTRACT
This paper describes an automated method and device to conduct the Chair Stand Tests of the Fullerton Functional Test Battery. The Fullerton Functional Test is a suite of physical tests designed to assess the physical fitness of older adults. The Chair Stand Tests, which include the Five Times Sit-to-Stand Test (5xSST) and the 30 Second Sit-to-Stand Test (30CST), are the standard for measuring lower-body strength in older adults. However, these tests are performed manually, which can be labor-intensive and prone to error. We developed a sensor-integrated chair that automatically captures the dynamic weight and distribution on the chair. The collected time series weight-sensor data is automatically uploaded for immediate determination of the sit-to-stand timing and counts, as well as providing a record for future comparison of lower-body strength progression. The automatic test administration can provide significant labor savings for medical personnel and deliver much more accurate data. Data from 10 patients showed good agreement between the manually collected and sensor-collected 30CST data (M = 0.5, SD = 1.58, 95% CI = 1.13). Additional data processing will be able to yield measurements of fatigue and balance and evaluate the mechanisms of failed standing attempts.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Contexto em Saúde: 1_ASSA2030 Problema de saúde: 1_recursos_humanos_saude Assunto principal: Aptidão Física Limite: Aged / Humans Idioma: En Revista: Sensors (Basel) Ano de publicação: 2024 Tipo de documento: Article País de afiliação: Estados Unidos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Contexto em Saúde: 1_ASSA2030 Problema de saúde: 1_recursos_humanos_saude Assunto principal: Aptidão Física Limite: Aged / Humans Idioma: En Revista: Sensors (Basel) Ano de publicação: 2024 Tipo de documento: Article País de afiliação: Estados Unidos
...