Your browser doesn't support javascript.
loading
Opportunistic screening with multiphase contrast-enhanced dual-layer spectral CT for osteoblastic lesions in prostate cancer compared with bone scintigraphy.
Liu, Ming-Cheng; Ho, Chi-Chang; Lin, Yen-Ting; Chai, Jyh-Wen; Hung, Siu-Wan; Wu, Chen-Hao; Li, Jian-Ri; Liu, Yi-Jui.
Afiliação
  • Liu MC; Department of Radiology, Taichung Veterans General Hospital, Taichung, Taiwan, ROC.
  • Ho CC; Ph.D. Program of Electrical and Communications Engineering, Feng Chia University, Taichung, Taiwan, ROC.
  • Lin YT; Department of Radiology, Taichung Veterans General Hospital, Taichung, Taiwan, ROC.
  • Chai JW; Department of Radiology, Taichung Veterans General Hospital, Taichung, Taiwan, ROC.
  • Hung SW; Institute of Clinical Medicine, National Yang-Ming University, Taipei, Taiwan, ROC.
  • Wu CH; Department of Radiology, Taichung Veterans General Hospital, Taichung, Taiwan, ROC.
  • Li JR; Department of Radiology, Taichung Veterans General Hospital, Taichung, Taiwan, ROC.
  • Liu YJ; Department of Radiology, Taichung Veterans General Hospital, Taichung, Taiwan, ROC.
Sci Rep ; 14(1): 5310, 2024 03 04.
Article em En | MEDLINE | ID: mdl-38438474
ABSTRACT
Our study aimed to compare bone scintigraphy and dual-layer detector spectral CT (DLCT) with multiphase contrast enhancement for the diagnosis of osteoblastic bone lesions in patients with prostate cancer. The patients with prostate cancer and osteoblastic bone lesions detected on DLCT were divided into positive bone scintigraphy group (pBS) and negative bone scintigraphy group (nBS) based on bone scintigraphy. A total of 106 patients (57 nBS and 49 pBS) was included. The parameters of each lesion were measured from DLCT including Hounsfield unit (HU), 40-140 keV monochromatic HU, effective nuclear numbers (Zeff), and Iodine no water (InW) value in non-contrast phase (N), the arterial phase (A), and venous phase (V). The slope of the spectral curve at 40 and 100 keV, the different values of the parameters between A and N phase (A-N), V and N phase (V-N), and hybrid prediction model with multiparameters were used to differentiate pBS from nBS. Receiver operating characteristic analysis was performed to compare the area under the curve (AUC) for differentiating the pBS group from the nBS group. The value of conventional HU values, slope, and InW in A-N and V-N, and hybrid model were significantly higher in the pBS group than in the nBS group. The hybrid model of all significant parameters had the highest AUC of 0.988, with 95.5% sensitivity and 94.6% specificity. DLCT with arterial contrast enhancement phase has the potential to serve as an opportunistic screening tool for detecting positive osteoblastic bone lesions, corresponding to those identified in bone scintigraphy.
Assuntos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Contexto em Saúde: 2_ODS3 Problema de saúde: 2_muertes_prematuras_enfermedades_notrasmisibles Assunto principal: Neoplasias da Próstata / Doenças Ósseas / Doenças das Cartilagens / Iodo Limite: Humans / Male Idioma: En Revista: Sci Rep Ano de publicação: 2024 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Contexto em Saúde: 2_ODS3 Problema de saúde: 2_muertes_prematuras_enfermedades_notrasmisibles Assunto principal: Neoplasias da Próstata / Doenças Ósseas / Doenças das Cartilagens / Iodo Limite: Humans / Male Idioma: En Revista: Sci Rep Ano de publicação: 2024 Tipo de documento: Article
...