Your browser doesn't support javascript.
loading
Comparison of torque expression among passive self-ligating brackets with different slot depths: An in vitro study.
Saraiva, Patrick Cavallini; Cruz, Murilo Henrique; Medeiros, Igor Studart; Bozelli, Jefferson Vinicius; Neto, José Rino; Paiva, João Batista de.
Afiliação
  • Saraiva PC; Department of Orthodontics, Faculty of Dentistry, University of São Paulo, São Paulo, Brazil.
  • Cruz MH; Department of Orthodontics, Faculty of Dentistry, University of São Paulo, São Paulo, Brazil. Electronic address: murilohcruz@usp.br.
  • Medeiros IS; Department of Biomaterials and Oral Biology, Faculty of Dentistry, University of São Paulo, São Paulo, Brazil.
  • Bozelli JV; Department of Orthodontics, Faculty of Dentistry, University of São Paulo, São Paulo, Brazil.
  • Neto JR; Department of Orthodontics, Faculty of Dentistry, University of São Paulo, São Paulo, Brazil.
  • Paiva JB; Department of Orthodontics, Faculty of Dentistry, University of São Paulo, São Paulo, Brazil.
Int Orthod ; 22(2): 100866, 2024 Jun.
Article em En | MEDLINE | ID: mdl-38479220
ABSTRACT

INTRODUCTION:

The aim of this study was to assess the interaction between a 0.019×0.025-inch (″) stainless steel archwire and two types of passive self-ligating brackets with the same slot height (0.022″) and different slot depths (0.028″ and 0.026″, and to measure the archwire/slot play as well as to compare the torque expression with archwire torsions of 12°, 24°, and 36°. MATERIAL AND

METHODS:

An experimental device was developed along with a universal testing machine to measure torque expression in two types of brackets with 0.028″ and 0.026″ slot depths. Analysis of variance (ANOVA) and Tukey's test were performed to identify the differences between groups.

RESULTS:

The 0.026″ slot bracket presented greater archwire/slot play when compared to the 0.028″ bracket. Torque expression with torsions of 24° and 36° were significantly higher in the 0.028″ depth brackets when compared to the 0.026″ depth brackets.

CONCLUSION:

The 0.022″×0.026″ passive self-ligating brackets attached with a 0.019″×0.025″ stainless steel archwire provided no greater torque control when compared to 0.022″×0.028″ passive self-ligating brackets.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Fios Ortodônticos / Aço Inoxidável / Teste de Materiais / Braquetes Ortodônticos / Desenho de Aparelho Ortodôntico / Torque / Análise do Estresse Dentário Limite: Humans Idioma: En Revista: Int Orthod Assunto da revista: ORTODONTIA Ano de publicação: 2024 Tipo de documento: Article País de afiliação: Brasil

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Fios Ortodônticos / Aço Inoxidável / Teste de Materiais / Braquetes Ortodônticos / Desenho de Aparelho Ortodôntico / Torque / Análise do Estresse Dentário Limite: Humans Idioma: En Revista: Int Orthod Assunto da revista: ORTODONTIA Ano de publicação: 2024 Tipo de documento: Article País de afiliação: Brasil
...