Your browser doesn't support javascript.
loading
Automated analysis of knee joint alignment using detailed angular values in long leg radiographs based on deep learning.
Lee, Hong Seon; Hwang, Sangchul; Kim, Sung-Hwan; Joon, Nam Bum; Kim, Hyeongmin; Hong, Yeong Sang; Kim, Sungjun.
Afiliação
  • Lee HS; Department of Radiology, Gangnam Severance Hospital, Yonsei University College of Medicine, 211, Eonju-ro, Gangnam-gu, Seoul, Republic of Korea.
  • Hwang S; Research Institute of Radiological Science, Center for Clinical Imaging Data Science, Yonsei University College of Medicine, Seoul, Republic of Korea.
  • Kim SH; Department of Orthopedic Surgery, Gangnam Severance Hospital, Yonsei University College of Medicine, Seoul, Republic of Korea.
  • Joon NB; Department of Orthopedic Surgery, Gangnam Severance Hospital, Yonsei University College of Medicine, Seoul, Republic of Korea.
  • Kim H; Department of Radiology, Gangnam Severance Hospital, Yonsei University College of Medicine, 211, Eonju-ro, Gangnam-gu, Seoul, Republic of Korea.
  • Hong YS; Department of Radiology, Gangnam Severance Hospital, Yonsei University College of Medicine, 211, Eonju-ro, Gangnam-gu, Seoul, Republic of Korea.
  • Kim S; Department of Radiology, Gangnam Severance Hospital, Yonsei University College of Medicine, 211, Eonju-ro, Gangnam-gu, Seoul, Republic of Korea. AGN70@yuhs.ac.
Sci Rep ; 14(1): 7226, 2024 03 27.
Article em En | MEDLINE | ID: mdl-38538685
ABSTRACT
Malalignment in the lower limb structure occurs due to various causes. Accurately evaluating limb alignment in situations where malalignment needs correction is necessary. To create an automated support system to evaluate lower limb alignment by quantifying mechanical tibiofemoral angle (mTFA), mechanical lateral distal femoral angle (mLDFA), medial proximal tibial angle (MPTA), and joint line convergence angle (JLCA) on full-length weight-bearing radiographs of both lower extremities. In this retrospective study, we analysed 404 radiographs from one hospital for algorithm development and testing and 30 radiographs from another hospital for external validation. The performance of segmentation algorithm was compared to that of manual segmentation using the dice similarity coefficient (DSC). The agreement of alignment parameters was assessed using the intraclass correlation coefficient (ICC) for internal and external validation. The time taken to load the data and measure the four alignment parameters was recorded. The segmentation algorithm demonstrated excellent agreement with human-annotated segmentation for all anatomical regions (average similarity 89-97%). Internal validation yielded good to very good agreement for all the alignment parameters (ICC ranges 0.7213-0.9865). Interobserver correlations between manual and automatic measurements in external validation were good to very good (ICC scores 0.7126-0.9695). The computer-aided measurement was 3.44 times faster than was the manual measurement. Our deep learning-based automated measurement algorithm accurately quantified lower limb alignment from radiographs and was faster than manual measurement.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Osteoartrite do Joelho / Aprendizado Profundo Limite: Humans Idioma: En Revista: Sci Rep Ano de publicação: 2024 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Osteoartrite do Joelho / Aprendizado Profundo Limite: Humans Idioma: En Revista: Sci Rep Ano de publicação: 2024 Tipo de documento: Article
...