Your browser doesn't support javascript.
loading
A Coupled Calibration Method for Dual Cameras-Projector System with Sub-Pixel Accuracy Feature Extraction.
Jia, Ran; Xue, Junpeng; Lu, Wenbo; Song, Zeyu; Xu, Zhichao; Lu, Shuxin.
Afiliação
  • Jia R; School of Aeronautics and Astronautics, Sichuan University, Chengdu 610065, China.
  • Xue J; School of Aeronautics and Astronautics, Sichuan University, Chengdu 610065, China.
  • Lu W; School of Aeronautics and Astronautics, Sichuan University, Chengdu 610065, China.
  • Song Z; School of Aeronautics and Astronautics, Sichuan University, Chengdu 610065, China.
  • Xu Z; School of Aeronautics and Astronautics, Sichuan University, Chengdu 610065, China.
  • Lu S; School of Aeronautics and Astronautics, Sichuan University, Chengdu 610065, China.
Sensors (Basel) ; 24(6)2024 Mar 20.
Article em En | MEDLINE | ID: mdl-38544249
ABSTRACT
Binocular structured light systems are widely used in 3D measurements. In the condition of complex and local highly reflective scenes, to obtain more 3D information, binocular systems are usually divided into two pairs of devices, each having a Single Camera and a Projector (SCP). In this case, the binocular system can be seen as Dual Cameras-Projector (DCP) system. In the DCP calibration, the Left-SCP and Right-SCP need to be calibrated separately, which leads to inconsistent parameters for the same projector, thus reducing the measurement accuracy. To solve this problem and improve manoeuvrability, a coupled calibration method using an orthogonal phase target is proposed. The 3D coordinates on a phase target are uniquely determined by the binocular camera in DCP, rather than being calculated separately in each SCP. This ensures the consistency of the projector parameters. The coordinates of the projector image plane are calculated through the unwrapped phase, while the parameters are calibrated by the plane calibration method. In order to extract sub-pixel accuracy feature points, a method based on polynomial fitting using an orthogonal phase target is exploited. The experimental results show that the reprojection error of our method is less than 0.033 pixels, which improves the calibration accuracy.
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Idioma: En Revista: Sensors (Basel) Ano de publicação: 2024 Tipo de documento: Article País de afiliação: China

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Idioma: En Revista: Sensors (Basel) Ano de publicação: 2024 Tipo de documento: Article País de afiliação: China
...