Interlaboratory Comparison of Antibody-Free LC-MS/MS Measurements of C-peptide and Insulin.
Moradian, Annie; Goonatilleke, Elisha; Lin, Tai-Tu; Hatten-Beck, Maya; Emrick, Michelle; Schepmoes, Athena A; Fillmore, Thomas L; MacCoss, Michael J; Sechi, Salvatore; Sobhani, Kimia; Little, Randie; Kabytaev, Kuanysh; van Eyk, Jennifer E; Qian, Wei-Jun; Hoofnagle, Andrew N.
Afiliação
  • Moradian A; Precision Biomarker Laboratories, Cedars-Sinai Medical Center, Los Angeles, CA, United States.
  • Goonatilleke E; Department of Laboratory Medicine and Pathology, University of Washington, Seattle, WA, United States.
  • Lin TT; Integrative Omics, Biological Sciences Division, Pacific Northwest National Laboratory, Richland, WA, United States.
  • Hatten-Beck M; Department of Laboratory Medicine and Pathology, University of Washington, Seattle, WA, United States.
  • Emrick M; Department of Laboratory Medicine and Pathology, University of Washington, Seattle, WA, United States.
  • Schepmoes AA; Integrative Omics, Biological Sciences Division, Pacific Northwest National Laboratory, Richland, WA, United States.
  • Fillmore TL; Integrative Omics, Biological Sciences Division, Pacific Northwest National Laboratory, Richland, WA, United States.
  • MacCoss MJ; Department of Genome Sciences, University of Washington, Seattle, WA, United States.
  • Sechi S; Division of Diabetes, Endocrinology, & Metabolic Diseases, National Institute of Diabetes and Digestive and Kidney Diseases, National Institutes of Health, Bethesda, MD, United States.
  • Sobhani K; Department of Pathology and Laboratory Medicine, Cedars-Sinai Medical Center, Los Angeles, CA, United States.
  • Little R; Department of Pathology and Anatomical Sciences, University of Missouri School of Medicine, Columbia, MO, United States.
  • Kabytaev K; Department of Pathology and Anatomical Sciences, University of Missouri School of Medicine, Columbia, MO, United States.
  • van Eyk JE; Precision Biomarker Laboratories, Cedars-Sinai Medical Center, Los Angeles, CA, United States.
  • Qian WJ; Department of Pathology and Laboratory Medicine, Cedars-Sinai Medical Center, Los Angeles, CA, United States.
  • Hoofnagle AN; Advanced Clinical Biosystems Research Institute, Smidt Heart Institute, Cedars-Sinai Medical Center, Los Angeles, CA, United States.
Clin Chem ; 70(6): 855-864, 2024 Jun 03.
Article em En | MEDLINE | ID: mdl-38549041
ABSTRACT

BACKGROUND:

The enhanced precision and selectivity of liquid chromatography-tandem mass spectrometry (LC-MS/MS) makes it an attractive alternative to certain clinical immunoassays. Easily transferrable work flows could help facilitate harmonization and ensure high-quality patient care. We aimed to evaluate the interlaboratory comparability of antibody-free multiplexed insulin and C-peptide LC-MS/MS measurements.

METHODS:

The laboratories that comprise the Targeted Mass Spectrometry Assays for Diabetes and Obesity Research (TaMADOR) consortium verified the performance of a validated peptide-based assay (reproducibility, linearity, and lower limit of the measuring interval [LLMI]). An interlaboratory comparison study was then performed using shared calibrators, de-identified leftover laboratory samples, and reference materials.

RESULTS:

During verification, the measurements were precise (2.7% to 3.7%CV), linear (4 to 15 ng/mL for C-peptide and 2 to 14 ng/mL for insulin), and sensitive (LLMI of 0.04 to 0.10 ng/mL for C-peptide and 0.03 ng/mL for insulin). Median imprecision across the 3 laboratories was 13.4% (inter-quartile range [IQR] 11.6%) for C-peptide and 22.2% (IQR 20.9%) for insulin using individual measurements, and 10.8% (IQR 8.7%) and 15.3% (IQR 14.9%) for C-peptide and insulin, respectively, when replicate measurements were averaged. Method comparison with the University of Missouri reference method for C-peptide demonstrated a robust linear correlation with a slope of 1.044 and r2 = 0.99.

CONCLUSIONS:

Our results suggest that combined LC-MS/MS measurements of C-peptide and insulin are robust and adaptable and that standardization with a reference measurement procedure could allow accurate and precise measurements across sites, which could be important to diabetes research and help patient care in the future.
Assuntos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Peptídeo C / Espectrometria de Massas em Tandem / Insulina Limite: Humans Idioma: En Revista: Clin Chem Assunto da revista: QUIMICA CLINICA Ano de publicação: 2024 Tipo de documento: Article País de afiliação: Estados Unidos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Peptídeo C / Espectrometria de Massas em Tandem / Insulina Limite: Humans Idioma: En Revista: Clin Chem Assunto da revista: QUIMICA CLINICA Ano de publicação: 2024 Tipo de documento: Article País de afiliação: Estados Unidos
...