Quantitative Microbial Risk Assessment Framework Incorporating Water Ages with Legionella pneumophila Growth Rates.
Clements, Emily; Crank, Katherine; Nerenberg, Robert; Atkinson, Ariel; Gerrity, Daniel; Hannoun, Deena.
Afiliação
  • Clements E; Southern Nevada Water Authority, P.O. Box 99954, Las Vegas, Nevada 89193, United States.
  • Crank K; Southern Nevada Water Authority, P.O. Box 99954, Las Vegas, Nevada 89193, United States.
  • Nerenberg R; Department of Civil & Environmental Engineering & Earth Science, University of Notre Dame, 156 Fitzpatrick Hall, Notre Dame, Indiana 46556, United States.
  • Atkinson A; Southern Nevada Water Authority, P.O. Box 99954, Las Vegas, Nevada 89193, United States.
  • Gerrity D; Southern Nevada Water Authority, P.O. Box 99954, Las Vegas, Nevada 89193, United States.
  • Hannoun D; Southern Nevada Water Authority, P.O. Box 99954, Las Vegas, Nevada 89193, United States.
Environ Sci Technol ; 58(15): 6540-6551, 2024 Apr 16.
Article em En | MEDLINE | ID: mdl-38574283
ABSTRACT
Water age in drinking water systems is often used as a proxy for water quality but is rarely used as a direct input in assessing microbial risk. This study directly linked water ages in a premise plumbing system to concentrations of Legionella pneumophila via a growth model. In turn, the L. pneumophila concentrations were used for a quantitative microbial risk assessment to calculate the associated probabilities of infection (Pinf) and clinically severe illness (Pcsi) due to showering. Risk reductions achieved by purging devices, which reduce water age, were also quantified. The median annual Pinf exceeded the commonly used 1 in 10,000 (10-4) risk benchmark in all scenarios, but the median annual Pcsi was always 1-3 orders of magnitude below 10-4. The median annual Pcsi was lower in homes with two occupants (4.7 × 10-7) than with one occupant (7.5 × 10-7) due to more frequent use of water fixtures, which reduced water ages. The median annual Pcsi for homes with one occupant was reduced by 39-43% with scheduled purging 1-2 times per day. Smart purging devices, which purge only after a certain period of nonuse, maintained these lower annual Pcsi values while reducing additional water consumption by 45-62%.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Contexto em Saúde: 2_ODS3 Problema de saúde: 2_enfermedades_transmissibles / 2_quimicos_contaminacion Assunto principal: Água Potável / Legionella / Legionella pneumophila Idioma: En Revista: Environ Sci Technol Ano de publicação: 2024 Tipo de documento: Article País de afiliação: Estados Unidos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Contexto em Saúde: 2_ODS3 Problema de saúde: 2_enfermedades_transmissibles / 2_quimicos_contaminacion Assunto principal: Água Potável / Legionella / Legionella pneumophila Idioma: En Revista: Environ Sci Technol Ano de publicação: 2024 Tipo de documento: Article País de afiliação: Estados Unidos
...