Hook-effect in MAGLUMI immunoassay for serum anti-GAD antibodies in neurological disorders: When "wrong" matrix is the right choice.
Musso, G; Zoccarato, M; Gallo, N; Plebani, M; Basso, D.
Afiliação
  • Musso G; Department of Medicine-DIMED, University of Padova, Padova, Italy; Laboratory Medicine Unit, University-Hospital of Padova, Padova, Italy. Electronic address: giulia.musso@unipd.it.
  • Zoccarato M; Neurology Unit, Ospedale Sant'Antonio, University-Hospital of Padova, Padova, Italy.
  • Gallo N; Laboratory Medicine Unit, University-Hospital of Padova, Padova, Italy.
  • Plebani M; Department of Medicine-DIMED, University of Padova, Padova, Italy; Laboratory Medicine Unit, University-Hospital of Padova, Padova, Italy.
  • Basso D; Department of Medicine-DIMED, University of Padova, Padova, Italy; Laboratory Medicine Unit, University-Hospital of Padova, Padova, Italy.
Clin Chim Acta ; 558: 119679, 2024 May 15.
Article em En | MEDLINE | ID: mdl-38642630
ABSTRACT
Antibodies against glutamic acid decarboxylase (anti-GAD) are a valuable diagnostic tool to detect severe autoimmune conditions as type 1 diabetes mellitus (T1DM) and anti-GAD related neurological disorders, having the latter more often anti-GAD concentrations in serum multiple times higher than in the former. Automated immunoassays, either with ELISA or chemiluminescent technology, are validated for diagnostic use in serum with analytical ranges suitable for T1DM diagnosis. In a patient presenting with a suspected autoimmune ataxia, anti-GAD testing on an automated chemiluminescent immunoassay (CLIA) resulted in slightly abnormal concentrations in serum (39.2 KIU/L) and very high concentrations in CSF (>280 KIU/L), thus prompting to proceed to serum dilutions to exclude a false negative result and a misdiagnosis. Different dilutions of serum resulted in nonlinear concentrations with endpoint result of 276,500 KIU/L at dilution 11000. CSF dilution was instead linear with endpoint result of 4050 KIU/L. In this case report we found that anti-GAD testing in CSF was essential to establish the clinical diagnosis and to suspect hook-effect in serum due to the excess of autoantibodies in this severe autoimmune condition.