[Surgical Stabilization of Traumatic Multiple Rib Fractures Using Absorbable Osteosynthesis Agent(u-HA/PLLA Composite Material)].
Kyobu Geka
; 77(4): 279-283, 2024 Apr.
Article
em Ja
| MEDLINE
| ID: mdl-38644175
ABSTRACT
In case that met several indication criteria with 4 or more rib fractures, we performed surgical stabilization of multiple fractured ribs using a plate and screw system( Super FIXORB MX) that was made of uncalcined hydroxyapatite (u-HA)/poly-L-lactic acid (PLLA) composite material with excellent bioactivity and absorbability. We report our clinical experience of 7 cases in which this device was used. Although there is still room for further consideration of the technique and the strength of the device itself, computed tomography( CT) images taken 9 months after surgery showed that the fixative device was almost assimilated with the bone at the fracture repair site in cases where fixation was successful.