Your browser doesn't support javascript.
loading
Preventing Staphylococci Surgical Site Infections with a Nitric Oxide-Releasing Poly(lactic acid-co-glycolic acid) Suture Material.
Griffin, Lauren; Garren, Mark Richard Stephen; Maffe, Patrick; Ghalei, Sama; Brisbois, Elizabeth J; Handa, Hitesh.
Afiliação
  • Griffin L; School of Chemical, Materials and Biomedical Engineering, College of Engineering, University of Georgia, Athens, Georgia 30602, United States.
  • Garren MRS; School of Chemical, Materials and Biomedical Engineering, College of Engineering, University of Georgia, Athens, Georgia 30602, United States.
  • Maffe P; School of Chemical, Materials and Biomedical Engineering, College of Engineering, University of Georgia, Athens, Georgia 30602, United States.
  • Ghalei S; School of Chemical, Materials and Biomedical Engineering, College of Engineering, University of Georgia, Athens, Georgia 30602, United States.
  • Brisbois EJ; School of Chemical, Materials and Biomedical Engineering, College of Engineering, University of Georgia, Athens, Georgia 30602, United States.
  • Handa H; School of Chemical, Materials and Biomedical Engineering, College of Engineering, University of Georgia, Athens, Georgia 30602, United States.
ACS Appl Bio Mater ; 7(5): 3086-3095, 2024 05 20.
Article em En | MEDLINE | ID: mdl-38652779
ABSTRACT
Of the 27 million surgeries performed in the United States each year, a reported 2.6% result in a surgical site infection (SSI), and Staphylococci species are commonly the culprit. Alternative therapies, such as nitric oxide (NO)-releasing biomaterials, are being developed to address this issue. NO is a potent antimicrobial agent with several modes of action, including oxidative and nitrosative damage, disruption of bacterial membranes, and dispersion of biofilms. For targeted antibacterial effects, NO is delivered by exogenous donor molecules, like S-nitroso-N-acetylpenicillamine (SNAP). Herein, the impregnation of SNAP into poly(lactic-co-glycolic acid) (PLGA) for SSI prevention is reported for the first time. The NO-releasing PLGA copolymer is fabricated and characterized by donor molecule loading, leaching, and the amount remaining after ethylene oxide sterilization. The swelling ratio, water uptake, static water contact angle, and tensile strength are also investigated. Furthermore, its cytocompatibility is tested against 3T3 mouse fibroblast cells, and its antimicrobial efficacy is assessed against multiple Staphylococci strains. Overall, the NO-releasing PLGA copolymer holds promise as a suture material for eradicating surgical site infections caused by Staphylococci strains. SNAP impregnation affords robust antibacterial properties while maintaining the cytocompatibility and mechanical integrity.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Infecção da Ferida Cirúrgica / Suturas / Materiais Biocompatíveis / Teste de Materiais / Copolímero de Ácido Poliláctico e Ácido Poliglicólico / Antibacterianos / Óxido Nítrico Limite: Animals Idioma: En Revista: ACS Appl Bio Mater Ano de publicação: 2024 Tipo de documento: Article País de afiliação: Estados Unidos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Infecção da Ferida Cirúrgica / Suturas / Materiais Biocompatíveis / Teste de Materiais / Copolímero de Ácido Poliláctico e Ácido Poliglicólico / Antibacterianos / Óxido Nítrico Limite: Animals Idioma: En Revista: ACS Appl Bio Mater Ano de publicação: 2024 Tipo de documento: Article País de afiliação: Estados Unidos
...