Your browser doesn't support javascript.
loading
An analysis of the factors involved in IOL decentration after phacoemulsification using CASIA 2 anterior segment optical coherence tomography.
de Paula, Alessandro; Gattazzo, Irene; Savini, Giacomo; Schiano Lomoriello, Domenico; Corsi, Andrea.
Afiliação
  • de Paula A; Ophthalmology Unit, Policlinico Casilino, Via Casilina, 1049, 00169, Rome, Italy. aledepaula@hotmail.it.
  • Gattazzo I; Ophthalmology Unit, NESMOS Department, St. Andrea Hospital, University of Rome "La Sapienza", Rome, Italy.
  • Savini G; IRCCS - Bietti Foundation, Rome, Italy.
  • Schiano Lomoriello D; IRCCS - Bietti Foundation, Rome, Italy.
  • Corsi A; Ophthalmology Unit, Policlinico Casilino, Via Casilina, 1049, 00169, Rome, Italy.
Int Ophthalmol ; 44(1): 194, 2024 Apr 24.
Article em En | MEDLINE | ID: mdl-38656707
ABSTRACT

PURPOSE:

To evaluate the magnitude of IOL transversal shift (ITS) after phacoemulsification and to analyse the factors contributing to IOL decentration and ITS.

METHODS:

94 consecutive patients who underwent cataract surgery and IOL implantation was enrolled. Each patient underwent anterior segment optical coherence tomography with CASIA 2 (Tomey, Nagoya, Japan) to assess crystalline lens decentration, thickness and diameter seven days preoperatively and at one and sixty days postoperatively. Univariate and multivariate linear regression analysis were performed to evaluate the determinants of ITS and final decentration.

RESULTS:

The preoperative crystalline lens diameter was associated with the ITS and with the IOL final decentration. A positive association between the final IOL decentration and the first post-surgical day decentration was found (p < 0.0001).

CONCLUSION:

Greater crystalline lens diameter was associated with greater decentration and with greater ITS. Day-one IOL decentration seems to be the main determinant of final IOL decentration.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Facoemulsificação / Tomografia de Coerência Óptica / Segmento Anterior do Olho Limite: Aged / Aged80 / Female / Humans / Male / Middle aged Idioma: En Revista: Int Ophthalmol Ano de publicação: 2024 Tipo de documento: Article País de afiliação: Itália

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Facoemulsificação / Tomografia de Coerência Óptica / Segmento Anterior do Olho Limite: Aged / Aged80 / Female / Humans / Male / Middle aged Idioma: En Revista: Int Ophthalmol Ano de publicação: 2024 Tipo de documento: Article País de afiliação: Itália
...