Your browser doesn't support javascript.
loading
Research on Anchorage Performance of the Foundation Ring for Wind Turbines.
Zhang, Junjun; Huang, Hao; Zhen, Li; Sun, Linyuan; Yang, Jiaxiang; Chen, Kang; Chen, Gaixin.
Afiliação
  • Zhang J; State Key Laboratory of Simulation and Regulation of Water Cycle in River Basin, Beijing 100038, China.
  • Huang H; China Institute of Water Resources and Hydropower Research, Beijing 100038, China.
  • Zhen L; Key Laboratory of Engineering Materials of Ministry of Water Resources, Beijing 100038, China.
  • Sun L; State Key Laboratory of Simulation and Regulation of Water Cycle in River Basin, Beijing 100038, China.
  • Yang J; China Institute of Water Resources and Hydropower Research, Beijing 100038, China.
  • Chen K; Key Laboratory of Engineering Materials of Ministry of Water Resources, Beijing 100038, China.
  • Chen G; State Key Laboratory of Simulation and Regulation of Water Cycle in River Basin, Beijing 100038, China.
Materials (Basel) ; 17(8)2024 Apr 09.
Article em En | MEDLINE | ID: mdl-38673074
ABSTRACT
The foundation ring (FR) is a steel component embedded within the concrete of a wind turbine foundation, playing a pivotal role in connecting the wind turbine tower to the foundation structure. In this paper, the FR-foundation connection is equivalent to the exposed foundation and the shallow foundation by analyzing the anchorage characteristics of the foundation ring. Based on the ABAQUS concrete damaged plasticity model, full-scale modeling of the wind turbine foundation is carried out. The influence of embedment depth, ring radius and base flange width of the foundation ring on moment capacity is simulated. Based on the observed stress distributions under ultimate loads, analytical expressions were proposed to estimate the variation law of anchorage load-bearing capacity in the ultimate load state. Compared with the numerical simulation, the average errors under different influencing factors are 8.2%, 9.6% and 10.8%, respectively. The results indicate that the base flange provided the majority of the moment capacity, though the contribution of the sidewall increased to 25-50% that of the base flange in later stages.
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Idioma: En Revista: Materials (Basel) Ano de publicação: 2024 Tipo de documento: Article País de afiliação: China