Your browser doesn't support javascript.
loading
Complication rates associated with nasoesophageal versus nasogastric feeding tube placement in dogs and cats: a randomised controlled trial.
Camacho, F; Humm, K.
Afiliação
  • Camacho F; Willows Veterinary Centre and Referral Service, Highlands Road, Shirley, Solihull, West Midlands, B90 4NH, UK.
  • Humm K; Queen Mother Hospital for Animals, The Royal Veterinary College, Hawkshead Lane, Hatfield, Hertfordshire, AL9 7TA, UK.
J Small Anim Pract ; 65(7): 417-423, 2024 Jul.
Article em En | MEDLINE | ID: mdl-38693785
ABSTRACT

OBJECTIVES:

To determine the rate of accidental placement of nasoenteric tubes into the respiratory tract. To compare the methods of checking correct tube placement. To compare the complication rates between nasoesophageal and nasogastric tubes. MATERIALS AND

METHODS:

Animals requiring nasoenteric feeding tubes were prospectively randomised to have either nasoesophageal or nasogastric tube placement. Various techniques for assessing tube position were compared with thoracic radiographic findings. Complications during placement and use were recorded.

RESULTS:

Ninety-seven animals (82 dogs and 15 cats) were studied. The tube was misplaced into the respiratory tract in three (3.1%) cases. No technique for checking placement was completely concordant with radiography but the presence of negative pressure at the thoracic inlet during placement was consistent with the presence of the tube in the oesophagus in 86.2% cases, while capnography can be considered to confirm tracheal placement. The overall rate of complications during tube placement was 25.8%, with mostly minor clinical complications reported. There was no significant difference in the new-onset regurgitation/vomiting rate, or complications while the tube was in situ between the nasoesophageal and nasogastric groups. CLINICAL

SIGNIFICANCE:

Misplacement of nasoenteric tubes is uncommon but a consistent alternative test to radiography for checking correct nasoenteric tube placement was not demonstrated. The choice of placement of either a nasoesophageal or nasogastric tube should be guided by clinician preference, and clients should be warned about possible complications during placement and while the nasoenteric tube is in situ.
Assuntos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Nutrição Enteral / Intubação Gastrointestinal Limite: Animals Idioma: En Revista: J Small Anim Pract Ano de publicação: 2024 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Nutrição Enteral / Intubação Gastrointestinal Limite: Animals Idioma: En Revista: J Small Anim Pract Ano de publicação: 2024 Tipo de documento: Article
...