Your browser doesn't support javascript.
loading
Irrigant dynamics of a back-to-back double side-vented needle in root canals with various tapers: a computational fluid dynamics study.
Singh, Surmayee; Zuber, Mohammad; Verekar, Prathmesh Pravin; Shetty, Tejaswini; Srikant, N; Thomas, Manuel S.
Afiliação
  • Singh S; Department of Conservative Dentistry and Endodontics, Manipal College of Dental Sciences Mangalore, Manipal Academy of Higher Education, Manipal, Karnataka, 576104, India.
  • Zuber M; Department of Aeronautical and Automobile Engineering, Manipal Institute of Technology, Manipal, Manipal Academy of Higher Education, Manipal, Karnataka, 576104, India.
  • Verekar PP; Department of Aeronautical and Automobile Engineering, Manipal Institute of Technology, Manipal, Manipal Academy of Higher Education, Manipal, Karnataka, 576104, India.
  • Shetty T; Department of Conservative Dentistry and Endodontics, Manipal College of Dental Sciences Mangalore, Manipal Academy of Higher Education, Manipal, Karnataka, 576104, India.
  • Srikant N; Department of Oral Pathology, Manipal College of Dental Sciences Mangalore, Manipal College of Dental Sciences Mangalore, Manipal Academy of Higher Education, Manipal, Karnataka, 576104, India.
  • Thomas MS; Department of Conservative Dentistry and Endodontics, Manipal College of Dental Sciences Mangalore, Manipal Academy of Higher Education, Manipal, Karnataka, 576104, India. manuel.st@manipal.edu.
Odontology ; 112(4): 1248-1256, 2024 Oct.
Article em En | MEDLINE | ID: mdl-38703256
ABSTRACT
Understanding the apical pressure and irrigant flow patterns in root canals is crucial for safe and effective irrigation. Therefore, this study aimed to assess the flow characteristics of irrigants in root canal models with varying tapers during final irrigation by employing various needle designs, including a back-to-back double-side-vented needle, through computational fluid dynamics. The root canal model was configured as a closed geometrical cone with a simulated apical zone (size 30) and features tapers of 4%, 6%, and 8%. Three needle types-open-ended needle (OEN), single side-vented needle (SSVN), and double side-vented needle (DSVN)-were investigated. The results indicated that for the 4% taper models, the open-ended needle generated the maximum apical pressure, followed by the double side-vented needle and the single side-vented needle. However, in the 6% and 8% tapering root canal models, the double-side-vented needle applied the lowest maximum apical pressure. Consequently, the DSVN can pose a risk for irrigant extrusion in minimally prepared canals due to heightened apical pressure. In wider canals, the DSVN exhibited lower apical pressure. The maximum irrigant replacement was observed with OEN compared to that of the closed-ended group for both flow rates. Additionally, compared with OENs, closed-ended needles exhibited nonuniform and lower shear wall stress.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Irrigantes do Canal Radicular / Preparo de Canal Radicular / Cavidade Pulpar / Desenho de Equipamento / Hidrodinâmica / Agulhas Limite: Humans Idioma: En Revista: Odontology Assunto da revista: ODONTOLOGIA Ano de publicação: 2024 Tipo de documento: Article País de afiliação: Índia

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Irrigantes do Canal Radicular / Preparo de Canal Radicular / Cavidade Pulpar / Desenho de Equipamento / Hidrodinâmica / Agulhas Limite: Humans Idioma: En Revista: Odontology Assunto da revista: ODONTOLOGIA Ano de publicação: 2024 Tipo de documento: Article País de afiliação: Índia
...