Your browser doesn't support javascript.
loading
Advanced Computational Methods for Radiation Dose Optimization in CT.
Rao, Shreekripa; Sharan, Krishna; Chandraguthi, Srinidhi Gururajarao; Dsouza, Rechal Nisha; David, Leena R; Ravichandran, Sneha; Mustapha, Mubarak Taiwo; Shettigar, Dilip; Uzun, Berna; Kadavigere, Rajagopal; Sukumar, Suresh; Ozsahin, Dilber Uzun.
Afiliação
  • Rao S; Department of Radiotherapy and Oncology, Manipal College of Health Professions, Manipal 576104, India.
  • Sharan K; Department of Radiotherapy and Oncology, Kasturba Medical College and Hospital, Manipal 576104, India.
  • Chandraguthi SG; Department of Radiotherapy and Oncology, Kasturba Medical College and Hospital, Manipal 576104, India.
  • Dsouza RN; Department of Radiotherapy and Oncology, Manipal College of Health Professions, Manipal 576104, India.
  • David LR; Department of Medical Imaging Technology, Manipal College of Health Professions, Manipal 576104, India.
  • Ravichandran S; Department of Medical Diagnostic Imaging, College of Health Sciences, University of Sharjah, Sharjah 27272, United Arab Emirates.
  • Mustapha MT; Department of Medical Imaging Technology, Manipal College of Health Professions, Manipal 576104, India.
  • Shettigar D; Operational Research Centre in Healthcare, Near East University, TRNC Mersin 10, Nicosia 99138, Turkey.
  • Uzun B; Department of Biomedical Engineering, Near East University, TRNC Mersin 10, Nicosia 99138, Turkey.
  • Kadavigere R; Department of Medical Imaging Technology, Manipal College of Health Professions, Manipal 576104, India.
  • Sukumar S; Operational Research Centre in Healthcare, Near East University, TRNC Mersin 10, Nicosia 99138, Turkey.
  • Ozsahin DU; Department of Mathematics, Near East University, TRNC Mersin 10, Nicosia 99138, Turkey.
Diagnostics (Basel) ; 14(9)2024 Apr 29.
Article em En | MEDLINE | ID: mdl-38732335
ABSTRACT

BACKGROUND:

In planning radiotherapy treatments, computed tomography (CT) has become a crucial tool. CT scans involve exposure to ionizing radiation, which can increase the risk of cancer and other adverse health effects in patients. Ionizing radiation doses for medical exposure must be kept "As Low As Reasonably Achievable". Very few articles on guidelines for radiotherapy-computed tomography scans are available. This paper reviews the current literature on radiation dose optimization based on the effective dose and diagnostic reference level (DRL) for head, neck, and pelvic CT procedures used in radiation therapy planning. This paper explores the strategies used to optimize radiation doses, and high-quality images for diagnosis and treatment planning.

METHODS:

A cross-sectional study was conducted on 300 patients with head, neck, and pelvic region cancer in our institution. The DRL, effective dose, volumetric CT dose index (CTDIvol), and dose-length product (DLP) for the present and optimized protocol were calculated. DRLs were proposed for the DLP using the 75th percentile of the distribution. The DLP is a measure of the radiation dose received by a patient during a CT scan and is calculated by multiplying the CT dose index (CTDI) by the scan length. To calculate a DRL from a DLP, a large dataset of DLP values obtained from a specific imaging procedure must be collected and can be used to determine the median or 75th-percentile DLP value for each imaging procedure.

RESULTS:

Significant variations were found in the DLP, CTDIvol, and effective dose when we compared both the standard protocol and the optimized protocol. Also, the optimized protocol was compared with other diagnostic and radiotherapy CT scan studies conducted by other centers. As a result, we found that our institution's DRL was significantly low. The optimized dose protocol showed a reduction in the CTDIvol (70% and 63%), DLP (60% and 61%), and effective dose (67% and 62%) for both head, neck, and pelvic scans.

CONCLUSIONS:

Optimized protocol DRLs were proposed for comparison purposes.
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Idioma: En Revista: Diagnostics (Basel) Ano de publicação: 2024 Tipo de documento: Article País de afiliação: Índia

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Idioma: En Revista: Diagnostics (Basel) Ano de publicação: 2024 Tipo de documento: Article País de afiliação: Índia
...