Your browser doesn't support javascript.
loading
Bifunctional oxidase-peroxidase mimicking Fe-Ce MOF on paper-based analytical devices to intensify luminol chemiluminescence: Application for measuring different sugars with a smartphone readout.
Hassanzadeh, Javad; Al Lawati, Haider A J; Bagheri, Nafiseh.
Afiliação
  • Hassanzadeh J; Department of Chemistry, College of Science, Sultan Qaboos University, Box 36, Al-Khod, 123, Oman.
  • Al Lawati HAJ; Department of Chemistry, College of Science, Sultan Qaboos University, Box 36, Al-Khod, 123, Oman. Electronic address: haiderl@squ.edu.om.
  • Bagheri N; Department of Chemistry, College of Science, Sultan Qaboos University, Box 36, Al-Khod, 123, Oman.
Talanta ; 276: 126219, 2024 Aug 15.
Article em En | MEDLINE | ID: mdl-38733936
ABSTRACT
This study presents a potent paper-based analytical device (PAD) for quantifying various sugars using an innovative bi-nanozyme made from a 2-dimensional Fe/Ce metal-organic framework (FeCe-BTC). The MOF showed excellent bifunctional peroxidase-oxidase activities, efficiently catalyzing luminol's chemiluminescence (CL) reaction. As a peroxidase-like nanozyme, FeCe-BTC could facilitate the dissociation of hydrogen peroxide (H2O2) into hydroxyl radicals, which then oxidize luminol. Additionally, it was also discovered that when reacting with H2O2, the MOF turns into a mixed-valence MOF, and acts as an oxidase nanozyme. This activity is caused by the generated Ce4+ ions in the structure of MOF that can directly oxidize luminol. The MOF was directly synthesized on the PAD and cascaded with specific natural enzymes to establish simple, rapid, and selective CL sensors for the measurement of different sugars. A cell phone was also used to record light intensities, which were then correlated to the analyte concentration. The designed PAD showed a wide linear range of 0.1-10 mM for glucose, fructose, and sucrose, with detection limits of 0.03, 0.04, and 0.04 mM, respectively. It showed satisfactory results in food and biological samples with recovery values ranging from 95.8 to 102.4 %, which makes it a promising candidate for point-of-care (POC) testing for food control and medicinal purposes.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Papel / Smartphone / Estruturas Metalorgânicas / Medições Luminescentes / Luminol Idioma: En Revista: Talanta Ano de publicação: 2024 Tipo de documento: Article País de afiliação: Omã

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Papel / Smartphone / Estruturas Metalorgânicas / Medições Luminescentes / Luminol Idioma: En Revista: Talanta Ano de publicação: 2024 Tipo de documento: Article País de afiliação: Omã
...