Development of a RP-HPLC method for simultaneous determination of atenolol, metoprolol tartrate and phenol red for in-situ rat intestinal perfusion studies.
Kir, Fatma; Dogan, Aysegul; Sahin, Selma.
Afiliação
  • Kir F; Hacettepe University, Faculty of Pharmacy, Department of Pharmaceutical Technology, 06100 Ankara, Turkey.
  • Dogan A; Hacettepe University, Faculty of Pharmacy, Department of Analytical Chemistry, 06100 Ankara, Turkey.
  • Sahin S; Hacettepe University, Faculty of Pharmacy, Department of Pharmaceutical Technology, 06100 Ankara, Turkey. Electronic address: selmas@hacettepe.edu.tr.
Article em En | MEDLINE | ID: mdl-38781808
ABSTRACT
Single-pass intestinal perfusion (SPIP) method is a widely used experimental model to determine the intestinal permeability of drugs. These studies are performed in the presence of a reference standard (metoprolol, MT) and a zero permeability marker (phenol red, PR). Therefore, it is important to develop a validated method for simultaneous determination of the investigated compound along with MT and PR. The aim of this study was to develop a reversed phase high-performance liquid chromatography (RP-HPLC) method with UV-detection for the simultaneous determination of atenolol (ATN), MT, and PR in the perfusion medium used in SPIP experiments. Separation of compounds were performed using an InertSustain C18 (250 × 4.6 mm, 5 µm) HPLC column at 35 °C. The mobile phase was a mixture of acetonitrile and phosphate buffer (pH 7.0, 12.5 mM) in gradient elution, and was delivered at a flow rate of 1 mL/min. The acetonitrile ratio of the mobile phase increased linearly from 10 to 35 % over 15 min. The injection volume was 20 µL, and ATN, MT and PR were detected at 224 nm. The retention times under optimum HPLC conditions were 5.028 min, 12.401 min, and 13.507 min for ATN, MT and PR, respectively. The developed RP-HPLC method was validated for selectivity, specificity, calibration curve and range, accuracy and precision, carry-over effect, stability, reinjection reproducibility, recovery and robustness. The method was linear for ATN (0.76-50 µg/mL), MT (1.14-50 µg/mL), and PR (0.47-20 µg/mL) with determination coefficients of 0.9999, 0.9994 and 0.9998, respectively. The results obtained for all validation parameters of the developed RP-HPLC method met the required limits of the ICH M10 Guideline.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Fenolsulfonaftaleína / Atenolol / Cromatografia de Fase Reversa / Metoprolol Limite: Animals Idioma: En Revista: J Chromatogr B Analyt Technol Biomed Life Sci Assunto da revista: ENGENHARIA BIOMEDICA Ano de publicação: 2024 Tipo de documento: Article País de afiliação: Turquia

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Fenolsulfonaftaleína / Atenolol / Cromatografia de Fase Reversa / Metoprolol Limite: Animals Idioma: En Revista: J Chromatogr B Analyt Technol Biomed Life Sci Assunto da revista: ENGENHARIA BIOMEDICA Ano de publicação: 2024 Tipo de documento: Article País de afiliação: Turquia
...