Your browser doesn't support javascript.
loading
Patient-specific cerebral 3D vessel model reconstruction using deep learning.
Koizumi, Satoshi; Kin, Taichi; Shono, Naoyuki; Kiyofuji, Satoshi; Umekawa, Motoyuki; Sato, Katsuya; Saito, Nobuhito.
Afiliação
  • Koizumi S; Department of Neurosurgery, The University of Tokyo Hospital, 7-3-1Bunkyo-Ku, HongoTokyo, 113-8655, Japan. sakoizumi-tky@umin.net.
  • Kin T; Department of Neurosurgery, The University of Tokyo Hospital, 7-3-1Bunkyo-Ku, HongoTokyo, 113-8655, Japan.
  • Shono N; Department of Medical Information Engineering, Graduate School of Medicine, The University of Tokyo, Tokyo, Japan.
  • Kiyofuji S; Department of Neurosurgery, The University of Tokyo Hospital, 7-3-1Bunkyo-Ku, HongoTokyo, 113-8655, Japan.
  • Umekawa M; Department of Neurosurgery, The University of Tokyo Hospital, 7-3-1Bunkyo-Ku, HongoTokyo, 113-8655, Japan.
  • Sato K; Department of Neurosurgery, The University of Tokyo Hospital, 7-3-1Bunkyo-Ku, HongoTokyo, 113-8655, Japan.
  • Saito N; Department of Neurosurgery, The University of Tokyo Hospital, 7-3-1Bunkyo-Ku, HongoTokyo, 113-8655, Japan.
Med Biol Eng Comput ; 62(10): 3225-3232, 2024 Oct.
Article em En | MEDLINE | ID: mdl-38802608
ABSTRACT
Three-dimensional vessel model reconstruction from patient-specific magnetic resonance angiography (MRA) images often requires some manual maneuvers. This study aimed to establish the deep learning (DL)-based method for vessel model reconstruction. Time of flight MRA of 40 patients with internal carotid artery aneurysms was prepared, and three-dimensional vessel models were constructed using the threshold and region-growing method. Using those datasets, supervised deep learning using 2D U-net was performed to reconstruct 3D vessel models. The accuracy of the DL-based vessel segmentations was assessed using 20 MRA images outside the training dataset. The dice coefficient was used as the indicator of the model accuracy, and the blood flow simulation was performed using the DL-based vessel model. The created DL model could successfully reconstruct a three-dimensional model in all 60 cases. The dice coefficient in the test dataset was 0.859. Of note, the DL-generated model proved its efficacy even for large aneurysms (> 10 mm in their diameter). The reconstructed model was feasible in performing blood flow simulation to assist clinical decision-making. Our DL-based method could successfully reconstruct a three-dimensional vessel model with moderate accuracy. Future studies are warranted to exhibit that DL-based technology can promote medical image processing.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Angiografia por Ressonância Magnética / Imageamento Tridimensional / Aprendizado Profundo Limite: Adult / Aged / Female / Humans / Male / Middle aged Idioma: En Revista: Med Biol Eng Comput Ano de publicação: 2024 Tipo de documento: Article País de afiliação: Japão

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Angiografia por Ressonância Magnética / Imageamento Tridimensional / Aprendizado Profundo Limite: Adult / Aged / Female / Humans / Male / Middle aged Idioma: En Revista: Med Biol Eng Comput Ano de publicação: 2024 Tipo de documento: Article País de afiliação: Japão
...