Your browser doesn't support javascript.
loading
Tensile strength of conventional glass ionomer cement and silver reinforced glass ionomer cement.
Sharma, Suman; Bagchi, Anandamoy; Mullick, Shruti; Deepyanti, Dubey; Sai Kiran, Katta Datta; Kumar, Amit; Surana, Pratik.
Afiliação
  • Sharma S; Department of Pediatric Dentistry, Pihu Dental Hospital, Noida, Uttar Pradesh, India.
  • Bagchi A; Department of Pedodontics & Preventive Dentistry, Kalinga Institute of Dental Sciences, KIIT Deemed to be University, Bhubaneswar, India.
  • Mullick S; Department of Prosthodontics Crown Bridge & Implantology, Sardar Patel Postgraduate institute of Dental and Medical Sciences, Lucknow, Uttar Pradesh, India.
  • Deepyanti D; Department of Conservative Dentistry and Endodontics, Dr D.Y Patil Dental College and Hospital, Dr D.Y Patil Vidyapeeth, Pimpri, Pune, Maharashtra, India.
  • Sai Kiran KD; Department of Conservative Dentistry and Endodontics, G. Pulla Reddy Dental College and Hospital, Kurnool, Andhra Pradesh, India.
  • Kumar A; Department of Dentistry, Lord Buddha Koshi Medical College and Hospital, Baijnathpur, Saharsa, Bihar-852221, India.
  • Surana P; Department of Pedodontics and Preventive Dentistry, Maitri College of Dentistry and Research Centre, Durg, Chhattisgarh, India.
Bioinformation ; 20(4): 391-393, 2024.
Article em En | MEDLINE | ID: mdl-38854768
ABSTRACT
A comparative analysis and assessment of the compressive strength (CS) and diametral tensile strength (DTS) between conventional glass ionomer cement (C-GIC) and a silver-reinforced GIC (S-GIC) variant is of interest. Ten specimens of both C-GIC (GC Fuji II, Japan) and S-GIC (Riva Silver, SDI, Australia) were fabricated for the evaluation of compressive strength, and an identical number of samples were created for the examination of tensile strength. These specimens were then tested using a universal testing apparatus. The results exhibited that both the compressive and diametral tensile strengths were significantly greater for the S-GIC cement in comparison to the C-GIC, with a notable p-value of 0.001. The findings suggest that S-GIC may be considered a viable alternative to conventional GIC.
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Idioma: En Revista: Bioinformation Ano de publicação: 2024 Tipo de documento: Article País de afiliação: Índia

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Idioma: En Revista: Bioinformation Ano de publicação: 2024 Tipo de documento: Article País de afiliação: Índia
...