Semaglutide and health risk: Development and validation of a LC-HRMS method for testing semaglutide in whole blood and application to real cases.
Arbouche, N; Blanchot, A; Raul, J S; Kintz, P.
Afiliação
  • Arbouche N; Institut de médecine légale, 11 rue Humann, 67000 Strasbourg, France. Electronic address: nadia.arbouche@hotmail.it.
  • Blanchot A; Institut de médecine légale, 11 rue Humann, 67000 Strasbourg, France.
  • Raul JS; Institut de médecine légale, 11 rue Humann, 67000 Strasbourg, France.
  • Kintz P; Institut de médecine légale, 11 rue Humann, 67000 Strasbourg, France; X-Pertise Consulting, 42 rue principale, 67206 Mittelhausbergen, France.
Article em En | MEDLINE | ID: mdl-38880054
ABSTRACT
The use of semaglutide, also known by its trade name Ozempic®, has been increasing worldwide in recent years due to its benefits in treating type II diabetes. Thanks to its effects on appetite regulation, in many countries it is also used to treat obesity. However, due to its promotion by social media and celebrities as a weight-loss treatment, semaglutide is misused by a non-diabetic and non-obese population and by a young public, which is the main target of these media. Following the alert by the ANSM (Agence nationale de sécurité du médicament) in France and the FDA (Food and Drug Administration) in the United States, which imposed the addition of fatal effects to the list of side effects, the misuse of semaglutide seems to be becoming a public health problem. For this reason, it seems important that a toxicology laboratory has the capacity to test for semaglutide in blood. In this study, the authors have developed and validated a method for the identification and quantification of semaglutide in whole blood using a LC-HRMS. After the addition of the internal standard (bovine insulin), the blood was subjected to protein precipitation using a mix of acetonitrile/methanol (7030,vv). The validation procedure demonstrated an acceptable linearity between 2 and 500 ng/mL. LOD and LOQ were 1 and 2 ng/mL, respectively. Intra and inter-day precision were below 20 % at three concentrations. The method was successfully applied to the blood samples of 3 diabetic patients under treatment of semaglutide. The samples tested positive with concentrations ranging from 31 to 70 ng/mL which fall within the limits of therapeutic blood concentrations described in the literature.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Peptídeos Semelhantes ao Glucagon Limite: Humans Idioma: En Revista: J Chromatogr B Analyt Technol Biomed Life Sci Assunto da revista: ENGENHARIA BIOMEDICA Ano de publicação: 2024 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Peptídeos Semelhantes ao Glucagon Limite: Humans Idioma: En Revista: J Chromatogr B Analyt Technol Biomed Life Sci Assunto da revista: ENGENHARIA BIOMEDICA Ano de publicação: 2024 Tipo de documento: Article
...