Your browser doesn't support javascript.
loading
Regular Tetrahedron Model for the Assessment of High-Resolution Mass Spectrometry Data of Four-Way Fractionated Dissolved Organic Matter.
Qiu, Junjie; Lü, Fan; Li, Xiao; Zhang, Hua; Xu, Bin; He, Pin-Jing.
Afiliação
  • Qiu J; Institute of Waste Treatment and Reclamation, Tongji University, Shanghai 200092, PR China.
  • Lü F; Institute of Waste Treatment and Reclamation, Tongji University, Shanghai 200092, PR China.
  • Li X; Shanghai Institute of Pollution Control and Ecological Security, Shanghai 200092, PR China.
  • Zhang H; Institute of Waste Treatment and Reclamation, Tongji University, Shanghai 200092, PR China.
  • Xu B; Institute of Waste Treatment and Reclamation, Tongji University, Shanghai 200092, PR China.
  • He PJ; Shanghai Institute of Pollution Control and Ecological Security, Shanghai 200092, PR China.
Environ Sci Technol ; 58(26): 11685-11694, 2024 Jul 02.
Article em En | MEDLINE | ID: mdl-38905014
ABSTRACT
A regular tetrahedron model was established to pierce the fractionation of dissolved organic matter (DOM) among quaternary components by using high-resolution mass spectrometry. The model can stereoscopically visualize molecular formulas of DOM to show the preference to each component according to the position in a regular tetrahedron. A classification method was subsequently developed to divide molecular formulas into 15 categories related to fractionation ratios, the relative change of which was demonstrated to be convergent with the uncertainty of mass peak area. The practicality of the regular tetrahedron model was verified by seven kinds of sludge from waste leachate treatment and sewage wastewater treatment plants by using stratification of extracellular polymeric substances coupled with Orbitrap MS as an example, presenting the DOM chemodiversity in stratified sludge flocs. Sensitivity analysis proved that classification results were relatively stable with the perturbation of four model parameters. Multinomial logistic regression analysis could further help identify the effect of molecular properties on the fractionation of DOM based on the classification results of the regular tetrahedron model. This model offers a methodology for the assessment of specificity of sequential extraction on DOM from solid or semisolid components and simplifies the complex mathematical expression of fractionation coefficients for quaternary components.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Esgotos / Espectrometria de Massas Idioma: En Revista: Environ Sci Technol Ano de publicação: 2024 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Esgotos / Espectrometria de Massas Idioma: En Revista: Environ Sci Technol Ano de publicação: 2024 Tipo de documento: Article
...