Your browser doesn't support javascript.
loading
Role of the gel spacer in safely delivering whole pelvic radiation therapy without central shielding in computed tomography-based image-guided adaptive brachytherapy for uterine cervical cancer patients.
Nagao, Ayaka; Murakami, Naoya; Sakuramachi, Madoka; Kashihara, Tairo; Takahashi, Kana; Kaneda, Tomoya; Inaba, Koji; Okuma, Kae; Okamoto, Hiroyuki; Nakayama, Yuko; Yonemori, Kan; Igaki, Hiroshi.
Afiliação
  • Nagao A; Department of Radiation Oncology, National Cancer Center Hospital, Tokyo, Japan; Cancer Medicine, Cooperative Graduate School, The Jikei University Graduate School of Medicine, Tokyo, Japan.
  • Murakami N; Department of Radiation Oncology, National Cancer Center Hospital, Tokyo, Japan; Department of Radiation Oncology, Juntendo University Graduate School of Medicine, Tokyo, Japan. Electronic address: n.murakami.zi@juntendo.ac.jp.
  • Sakuramachi M; Department of Radiation Oncology, National Cancer Center Hospital, Tokyo, Japan.
  • Kashihara T; Department of Radiation Oncology, National Cancer Center Hospital, Tokyo, Japan.
  • Takahashi K; Department of Radiation Oncology, National Cancer Center Hospital, Tokyo, Japan.
  • Kaneda T; Department of Radiation Oncology, National Cancer Center Hospital, Tokyo, Japan.
  • Inaba K; Department of Radiation Oncology, National Cancer Center Hospital, Tokyo, Japan.
  • Okuma K; Department of Radiation Oncology, National Cancer Center Hospital, Tokyo, Japan.
  • Okamoto H; Radiation Safety and Quality Assurance Division, National Cancer Center Hospital, Tokyo, Japan.
  • Nakayama Y; Department of Radiation Oncology, National Cancer Center Hospital, Tokyo, Japan.
  • Yonemori K; Cancer Medicine, Cooperative Graduate School, The Jikei University Graduate School of Medicine, Tokyo, Japan; Department of Medical Oncology, National Cancer Center Hospital, Tokyo, Japan.
  • Igaki H; Department of Radiation Oncology, National Cancer Center Hospital, Tokyo, Japan.
Brachytherapy ; 2024 Jun 27.
Article em En | MEDLINE | ID: mdl-38942713
ABSTRACT

BACKGROUND:

To protect the rectum and bladder from high dose exposure, the Japanese guidelines for managing uterine cervical carcinoma recommend pelvic irradiation with central shielding (CS). Conversely, the European Society for Radiotherapy and Oncology (ESTRO) and the American Brachytherapy Society (ABS) guidelines recommend delivering ≥85 Gy to high-risk clinical target volume D90 (CTVHR D90%). In this study, we investigated whether a gel spacer can enable the safe delivery of the ESTRO/ABS-recommended doses to the target while observing dose constraints for the OARs without using CS in external beam radiation therapy (EBRT). MATERIALS AND

METHODS:

Twenty patients who received definitive radiation therapy without CS and were treated by brachytherapy with a gel spacer between 2017 and 2022 were retrospectively reviewed. The cumulative doses of EBRT and brachytherapy treatment outcomes and incidence of adverse events were also examined.

RESULTS:

The median cumulative CTVHR D90%, rectum D2cm3, and bladder D2cm3 were 86.6 Gy, 62.9 Gy, and 72.0 Gy, respectively. The 2-year local control rate was 95%. There were no CTCAE ≥Grade 3 late gastrointestinal or genitourinary adverse events.

CONCLUSIONS:

The use of gel spacer can enable ESTRO/ABS-recommended dose constraints even without using CS in EBRT, with favorable outcomes and low adverse event rates.
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Idioma: En Revista: Brachytherapy Assunto da revista: RADIOTERAPIA Ano de publicação: 2024 Tipo de documento: Article País de afiliação: Japão

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Idioma: En Revista: Brachytherapy Assunto da revista: RADIOTERAPIA Ano de publicação: 2024 Tipo de documento: Article País de afiliação: Japão
...