Your browser doesn't support javascript.
loading
Advanced Myocardial MRI Tissue Characterization Combining Contrast Agent-Free T1-Rho Mapping With Fully Automated Analysis.
de Villedon de Naide, Victor; Narceau, Kalvin; Ozenne, Valery; Villegas-Martinez, Manuel; Nogues, Victor; Brillet, Nina; Huiyue Zhang, Jana; Benlala, Ilyes; Stuber, Matthias; Cochet, Hubert; Bustin, Aurélien.
Afiliação
  • de Villedon de Naide V; IHU LIRYC, Electrophysiology and Heart Modeling Institute, Université de Bordeaux, INSERM, Centre de Recherche Cardio-Thoracique de Bordeaux, U1045, Pessac, France.
  • Narceau K; Department of Cardiothoracic Imaging, Hôpital Cardiologique du Haut-Lévêque, CHU de Bordeaux, Pessac, France.
  • Ozenne V; IHU LIRYC, Electrophysiology and Heart Modeling Institute, Université de Bordeaux, INSERM, Centre de Recherche Cardio-Thoracique de Bordeaux, U1045, Pessac, France.
  • Villegas-Martinez M; IHU LIRYC, Electrophysiology and Heart Modeling Institute, Université de Bordeaux, INSERM, Centre de Recherche Cardio-Thoracique de Bordeaux, U1045, Pessac, France.
  • Nogues V; IHU LIRYC, Electrophysiology and Heart Modeling Institute, Université de Bordeaux, INSERM, Centre de Recherche Cardio-Thoracique de Bordeaux, U1045, Pessac, France.
  • Brillet N; Department of Cardiothoracic Imaging, Hôpital Cardiologique du Haut-Lévêque, CHU de Bordeaux, Pessac, France.
  • Huiyue Zhang J; IHU LIRYC, Electrophysiology and Heart Modeling Institute, Université de Bordeaux, INSERM, Centre de Recherche Cardio-Thoracique de Bordeaux, U1045, Pessac, France.
  • Benlala I; IHU LIRYC, Electrophysiology and Heart Modeling Institute, Université de Bordeaux, INSERM, Centre de Recherche Cardio-Thoracique de Bordeaux, U1045, Pessac, France.
  • Stuber M; Department of Diagnostic and Interventional Radiology, Lausanne University Hospital and University of Lausanne, Lausanne, Switzerland.
  • Cochet H; Department of Cardiothoracic Imaging, Hôpital Cardiologique du Haut-Lévêque, CHU de Bordeaux, Pessac, France.
  • Bustin A; IHU LIRYC, Electrophysiology and Heart Modeling Institute, Université de Bordeaux, INSERM, Centre de Recherche Cardio-Thoracique de Bordeaux, U1045, Pessac, France.
J Magn Reson Imaging ; 2024 Jul 01.
Article em En | MEDLINE | ID: mdl-38949101
ABSTRACT

BACKGROUND:

Myocardial T1-rho (T1ρ) mapping is a promising method for identifying and quantifying myocardial injuries without contrast agents, but its clinical use is hindered by the lack of dedicated analysis tools.

PURPOSE:

To explore the feasibility of clinically integrated artificial intelligence-driven analysis for efficient and automated myocardial T1ρ mapping. STUDY TYPE Retrospective. POPULATION Five hundred seventy-three patients divided into a training (N = 500) and a test set (N = 73) including ischemic and nonischemic cases. FIELD STRENGTH/SEQUENCE Single-shot bSSFP T1ρ mapping sequence at 1.5 T. ASSESSMENT The automated process included left ventricular (LV) wall segmentation, right ventricular insertion point detection and creation of a 16-segment model for segmental T1ρ value analysis. Two radiologists (20 and 7 years of MRI experience) provided ground truth annotations. Interobserver variability and segmentation quality were assessed using the Dice coefficient with manual segmentation as reference standard. Global and segmental T1ρ values were compared. Processing times were measured. STATISTICAL TESTS Intraclass correlation coefficients (ICCs) and Bland-Altman analysis (bias ±2SD); Paired Student's t-tests and one-way ANOVA. A P value <0.05 was considered significant.

RESULTS:

The automated approach significantly reduced processing time (3 seconds vs. 1 minute 51 seconds ± 22 seconds). In the test set, automated LV wall segmentation closely matched manual results (Dice 81.9% ± 9.0) and closely aligned with interobserver segmentation (Dice 82.2% ± 6.5). Excellent ICCs were achieved on a patient basis (0.94 [95% CI 0.91 to 0.96]) with bias of -0.93 cm2 ± 6.60. There was no significant difference in global T1ρ values between manual (54.9 msec ± 4.6; 95% CI 53.8 to 56.0 msec, range 46.6-70.9 msec) and automated processing (55.4 msec ± 5.1; 95% CI 54.2 to 56.6 msec; range 46.4-75.1 msec; P = 0.099). The pipeline demonstrated a high level of agreement with manual-derived T1ρ values at the patient level (ICC = 0.85; bias +0.52 msec ± 5.18). No significant differences in myocardial T1ρ values were found between methods across the 16 segments (P = 0.75). DATA

CONCLUSION:

Automated myocardial T1ρ mapping shows promise for the rapid and noninvasive assessment of heart disease. EVIDENCE LEVEL 3 TECHNICAL EFFICACY Stage 1.
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Idioma: En Revista: J Magn Reson Imaging Assunto da revista: DIAGNOSTICO POR IMAGEM Ano de publicação: 2024 Tipo de documento: Article País de afiliação: França

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Idioma: En Revista: J Magn Reson Imaging Assunto da revista: DIAGNOSTICO POR IMAGEM Ano de publicação: 2024 Tipo de documento: Article País de afiliação: França
...