Your browser doesn't support javascript.
loading
Discussing on the Aortic Coverage in Type B Aortic Dissection Treatment: A Comprehensive Scoping Review.
Bissacco, Daniele; de Kort, Jasper F; Ramella, Anna; Allievi, Sara; Bellotti, Paolo; Casana, Renato; Domanin, Maurizio; Migliavacca, Francesco; Trimarchi, Santi.
Afiliação
  • Bissacco D; Department of Clinical Sciences and Community Health, University of Milan, 20148 Milan, Italy.
  • de Kort JF; Section of Vascular Surgery, Cardio Thoracic Vascular Department, Foundation IRCCS Ca' Granda Ospedale Maggiore Policlinico, 20122 Milan, Italy.
  • Ramella A; Department of Chemistry, Materials and Chemical Engineering "G. Natta", Politecnico di Milano, 20133 Milan, Italy.
  • Allievi S; Department of Chemistry, Materials and Chemical Engineering "G. Natta", Politecnico di Milano, 20133 Milan, Italy.
  • Bellotti P; Department of Vascular Surgery, Santa Chiara Hospital, 38122 Trento, Italy.
  • Casana R; Section of Vascular Surgery, Cardio Thoracic Vascular Department, Foundation IRCCS Ca' Granda Ospedale Maggiore Policlinico, 20122 Milan, Italy.
  • Domanin M; Department of Cardiology, Istituto Auxologico Italiano, IRCCS, 20145 Milan, Italy.
  • Migliavacca F; Department of Clinical Sciences and Community Health, University of Milan, 20148 Milan, Italy.
  • Trimarchi S; Section of Vascular Surgery, Cardio Thoracic Vascular Department, Foundation IRCCS Ca' Granda Ospedale Maggiore Policlinico, 20122 Milan, Italy.
J Clin Med ; 13(13)2024 Jul 02.
Article em En | MEDLINE | ID: mdl-38999462
ABSTRACT

OBJECTIVE:

The objective of this study is to investigate and address the question surrounding the determination of the optimal endograft length of coverage during TEVAR for type B aortic dissection (TBAD), with a particular emphasis on the distal landing zone (DLZ). DATA SOURCES MEDLINE, Scopus, and Web of Science databases were used.

METHODS:

The PRISMA-ScR statement was followed.

RESULTS:

Several variables can contribute to the length of coverage during TEVAR in TBAD patient. Baseline patient's characteristics, TBAD-related features, the type of endoprosthesis, and postoperative graft behaviour may contribute to the choice of coverage.

CONCLUSIONS:

No robust data have been published regarding the optimal length of TEVAR. Therefore, reporting the percentage of covered aorta and improving computational studies should be valorised to improve postoperative outcomes.
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Idioma: En Revista: J Clin Med Ano de publicação: 2024 Tipo de documento: Article País de afiliação: Itália