Size and isotope analysis of individual nanoparticles by multi-collector ICP-MS using "event-triggered signal capture" with a high-speed oscilloscope.
Xing, Pengju; Belshaw, Nicholas Stanley; Dong, Junhang; Li, Lujie; Geng, Yuanhui; Zheng, Hongtao; Liu, Xing; Zhu, Zhenli.
Afiliação
  • Xing P; State Key Laboratory of Biogeology and Environmental Geology, School of Earth Sciences, China University of Geosciences, Wuhan, Hubei, 430078, China.
  • Belshaw NS; State Key Laboratory of Biogeology and Environmental Geology, School of Earth Sciences, China University of Geosciences, Wuhan, Hubei, 430078, China; Retired, Oxford University, Oxford, OX1 3PR, UK.
  • Dong J; State Key Laboratory of Biogeology and Environmental Geology, School of Earth Sciences, China University of Geosciences, Wuhan, Hubei, 430078, China; Faculty of Material Science and Chemistry, China University of Geosciences, Wuhan, Hubei, 430078, China.
  • Li L; Faculty of Material Science and Chemistry, China University of Geosciences, Wuhan, Hubei, 430078, China.
  • Geng Y; Faculty of Material Science and Chemistry, China University of Geosciences, Wuhan, Hubei, 430078, China.
  • Zheng H; Faculty of Material Science and Chemistry, China University of Geosciences, Wuhan, Hubei, 430078, China.
  • Liu X; State Key Laboratory of Biogeology and Environmental Geology, School of Earth Sciences, China University of Geosciences, Wuhan, Hubei, 430078, China.
  • Zhu Z; State Key Laboratory of Biogeology and Environmental Geology, School of Earth Sciences, China University of Geosciences, Wuhan, Hubei, 430078, China; Faculty of Material Science and Chemistry, China University of Geosciences, Wuhan, Hubei, 430078, China. Electronic address: zlzhu@cug.edu.cn.
Talanta ; 278: 126540, 2024 Jul 10.
Article em En | MEDLINE | ID: mdl-39003837
ABSTRACT
Accurate quantitative elemental and isotope analysis of nanoparticles at the single-particle level is crucial for better understanding their origin, properties and behaviors. Single particle inductively coupled plasma-mass spectrometry (spICP-MS) has emerged as a promising technique for nanoparticle analysis. However, challenges persist in obtaining accurate and consistent element profiles and ratios for small-sized nanoparticles by conventional quadrupole (QMS) or time-of-flight mass analyzers (TOF-MS) due to their low level and transient nature. In this paper, we present a novel analytical method for single nanoparticle analysis using multiple collector ICP-MS (MC-ICP-MS) combined with a modern high-speed digital oscilloscope. The single particle events are acquired using an "event-triggered signal capture" (ETSC) technique, which enables the simultaneously capture and visualization of multiple isotopes of transient individual particle profiles with nanosecond time resolution. This greatly facilitates precise and efficient analysis of nanoparticles. The minimum detectable particle size is calculated to be as small as 8 nm (∼1 ag 109Ag) for AgNPs. Based on the 109/107Ag ratios obtained from 2000 particles, the precisions of 109/107Ag ratio measurements on 20 nm, 40 nm, 60 nm, 80 nm and 100 nm were approximately 0.086 (SD), 0.063 (SD), 0.051 (SD), 0.040 (SD), and 0.029 (SD), which is limited by counting statistics of the isotopic signals. Furthermore, the achieved standard error of 109/107Ag can be reduced to sub-permil level (0.7 ‰) even for the measurement of 20 nm AgNPs (N = 17,000). These results demonstrate that the ETSC provides a unique method for isotope analysis of single particles, holding great potential for enhancing our understanding of nanoparticles.
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Idioma: En Revista: Talanta Ano de publicação: 2024 Tipo de documento: Article País de afiliação: China