Stably suppressing laser relative intensity noise on a 3 × 3 coupler interferometric system.
Opt Lett ; 49(14): 3950-3953, 2024 Jul 15.
Article em En | MEDLINE | ID: mdl-39008748
ABSTRACT
A 3 × 3 coupler multiphase demodulation scheme is proposed to eliminate the impact of working point drifting and the laser relative intensity noise (RIN) on a 3 × 3 coupler interferometric system. An ellipse-fitting algorithm (EFA) is applied to fit the two interference signals of the 3 × 3 coupler in order, then the ATAN algorithm is applied to obtain three noise-containing signals with specific trigonometric relationships. By averaging the three signals, the demodulated phase noise induced from RIN can be effectively eliminated. The experimental results show that compared with the asymmetric demodulation scheme without intensity noise control, the noise floor of the proposed scheme decreases from 4.5 to 1 µrad/√Hz at 1 kHz and 2.7 to 0.8 µrad/√Hz at 3 kHz. At high frequencies, the average noise floor level is reduced from 10 to 0.9 µrad/√Hz, a reduction of about 21 dB. Furthermore, the variation range of the average noise floor is reduced from 5.4 to 0.17 µrad /√Hz within 100 s.

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Idioma: En Revista: Opt Lett / Opt. lett. (Online) / Optics letters (Online) Ano de publicação: 2024 Tipo de documento: Article