An AIE-active tetra-aryl imidazole-derived chemodosimeter for turn-on recognition of hydrazine and its bioimaging in living cells.
Li, Qing-Xiu; Yuan, Yan-Ju; Cheng, Rui-Xing; Ma, Yu; Tan, Rui; Wang, Ya-Wen; Peng, Yu.
Afiliação
  • Li QX; School of Chemistry, School of Life Science and Engineering, Southwest Jiaotong University, Chengdu 610031, People's Republic of China. tanruiswjtu@sohu.com.
  • Yuan YJ; School of Chemistry, School of Life Science and Engineering, Southwest Jiaotong University, Chengdu 610031, People's Republic of China. tanruiswjtu@sohu.com.
  • Cheng RX; School of Chemistry, School of Life Science and Engineering, Southwest Jiaotong University, Chengdu 610031, People's Republic of China. tanruiswjtu@sohu.com.
  • Ma Y; School of Chemistry, School of Life Science and Engineering, Southwest Jiaotong University, Chengdu 610031, People's Republic of China. tanruiswjtu@sohu.com.
  • Tan R; School of Chemistry, School of Life Science and Engineering, Southwest Jiaotong University, Chengdu 610031, People's Republic of China. tanruiswjtu@sohu.com.
  • Wang YW; School of Chemistry, School of Life Science and Engineering, Southwest Jiaotong University, Chengdu 610031, People's Republic of China. tanruiswjtu@sohu.com.
  • Peng Y; School of Chemistry, School of Life Science and Engineering, Southwest Jiaotong University, Chengdu 610031, People's Republic of China. tanruiswjtu@sohu.com.
Org Biomol Chem ; 22(30): 6135-6140, 2024 07 31.
Article em En | MEDLINE | ID: mdl-39011846
ABSTRACT
A new chemodosimeter SWJT-31 with an aggregation-induced emission (AIE) effect was designed and constructed. Upon increasing the water fraction in the solution, it exhibited typical AIE, which showed bright red fluorescence at 610 nm. SWJT-31 could sensitively and specifically recognize hydrazine by the TICT effect with an LOD of 33.8 nM, which was much lower than the standard of the USEPA. A portable test strip prepared using SWJT-31 was also developed for the visual detection of hydrazine. Eventually, it was successfully used for the detection of hydrazine in water samples and HeLa cells.
Assuntos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Corantes Fluorescentes / Hidrazinas / Imidazóis Limite: Humans Idioma: En Revista: Org Biomol Chem Assunto da revista: BIOQUIMICA / QUIMICA Ano de publicação: 2024 Tipo de documento: Article