Your browser doesn't support javascript.
loading
An octahedral Mach B-dot probe for 3D flows and magnetic fields in the edge of reversed field pinches.
Sellner, A M; von der Linden, J; Himura, H; Reksoatmodjo, R; Sears, J; You, S; Almagri, A F; McCollam, K J; Reyfman, M; Rouda, C C; Sarff, J S.
Afiliação
  • Sellner AM; Department of Physics, University of Wisconsin, Madison, Wisconsin 53706, USA.
  • von der Linden J; Max-Planck-Institute für Plasmaphysik, 85748 Garching, Germany.
  • Himura H; Department of Electronics, Kyoto Institute of Technology, Kyoto 606-8585, Japan.
  • Reksoatmodjo R; Lawrence Livermore National Laboratory, Livermore, California 94550, USA.
  • Sears J; Lawrence Livermore National Laboratory, Livermore, California 94550, USA.
  • You S; HelicitySpace Corp., Pasadena, California 91107, USA.
  • Almagri AF; Department of Physics, University of Wisconsin, Madison, Wisconsin 53706, USA.
  • McCollam KJ; Department of Physics, University of Wisconsin, Madison, Wisconsin 53706, USA.
  • Reyfman M; Department of Physics, University of Wisconsin, Madison, Wisconsin 53706, USA.
  • Rouda CC; Department of Physics, University of Wisconsin, Madison, Wisconsin 53706, USA.
  • Sarff JS; Department of Physics, University of Wisconsin, Madison, Wisconsin 53706, USA.
Rev Sci Instrum ; 95(7)2024 Jul 01.
Article em En | MEDLINE | ID: mdl-39072731
ABSTRACT
Measurements and simulations show that plasma relaxation processes in the reversed field pinch drive and redistribute both magnetic flux and momentum. To examine this relaxation process, a new 3D Mach B-dot probe has been constructed. This probe collects ion saturation currents through six molybdenum electrodes arranged on the flattened vertices of an octahedron made of boron nitride (BN). The ion saturation current flows through configurable voltage dividers for measurement and returns through one of six selectable return electrodes equally spaced along the 12 cm BN probe arm. In addition, the probe arm houses three B-dot magnetic pickup coils in the BN stalk immediately below to the octahedron, to measure the local magnetic field. Inserted in the Madison Symmetric Torus (MST) during deuterium discharges with 220 kA plasma current, density of 0.8 × 1013 cm-3, the probe collects ion saturation currents with sawtooth-like peaks correlated with relaxation events. This compact octahedral design fitting six Mach electrode surfaces within a 1 cm3 cube will enable future multi-point, multi-field probes compatible with the 1.5 in. ports of MST. Such probes will allow for flow circulation, current, and canonical vorticity to be calculated in the center of the finite difference stencil formed by the measurement locations.

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Idioma: En Revista: Rev Sci Instrum Ano de publicação: 2024 Tipo de documento: Article País de afiliação: Estados Unidos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Idioma: En Revista: Rev Sci Instrum Ano de publicação: 2024 Tipo de documento: Article País de afiliação: Estados Unidos
...