Your browser doesn't support javascript.
loading
Accuracy of routine laboratory tests to predict mortality and deterioration to severe or critical COVID-19 in people with SARS-CoV-2.
De Rop, Liselore; Bos, David Ag; Stegeman, Inge; Holtman, Gea; Ochodo, Eleanor A; Spijker, René; Otieno, Jenifer A; Alkhlaileh, Fade; Deeks, Jonathan J; Dinnes, Jacqueline; Van den Bruel, Ann; McInnes, Matthew Df; Leeflang, Mariska Mg; Verbakel, Jan Y.
Afiliação
  • De Rop L; Department of Public Health and Primary Care, KU Leuven, Leuven, Belgium.
  • Bos DA; Department of Public Health and Primary Care, KU Leuven, Leuven, Belgium.
  • Stegeman I; Department of Otorhinolaryngology and Head & Neck Surgery, University Medical Center Utrecht, Utrecht, Netherlands.
  • Holtman G; Brain Center, University Medical Center Utrecht, Utrecht, Netherlands.
  • Ochodo EA; Department of Primary- and Long-term Care, University of Groningen, University Medical Centre Groningen, Groningen, Netherlands.
  • Spijker R; Centre for Global Health Research, Kenya Medical Research Institute, Kisumu, Kenya.
  • Otieno JA; Centre for Evidence-based Health Care, Department of Global Health, Faculty of Medicine and Health Sciences, Stellenbosch University, Cape Town, South Africa.
  • Alkhlaileh F; Cochrane Netherlands, Julius Center for Health Sciences and Primary Care, University Medical Center Utrecht, Utrecht University, Utrecht, Netherlands.
  • Deeks JJ; Medical Library, Amsterdam UMC, University of Amsterdam, Amsterdam Public Health, Amsterdam, Netherlands.
  • Dinnes J; Centre for Global Health Research, Kenya Medical Research Institute, Kisumu, Kenya.
  • Van den Bruel A; Department of Public Health and Primary Care, KU Leuven, Leuven, Belgium.
  • McInnes MD; Test Evaluation Research Group, Institute of Applied Health Research, University of Birmingham, Birmingham, UK.
  • Leeflang MM; NIHR Birmingham Biomedical Research Centre, University Hospitals Birmingham NHS Foundation Trust and University of Birmingham, Birmingham, UK.
  • Verbakel JY; NIHR Birmingham Biomedical Research Centre, University Hospitals Birmingham NHS Foundation Trust and University of Birmingham, Birmingham, UK.
Cochrane Database Syst Rev ; 8: CD015050, 2024 08 06.
Article em En | MEDLINE | ID: mdl-39105481
ABSTRACT

BACKGROUND:

Identifying patients with COVID-19 disease who will deteriorate can be useful to assess whether they should receive intensive care, or whether they can be treated in a less intensive way or through outpatient care. In clinical care, routine laboratory markers, such as C-reactive protein, are used to assess a person's health status.

OBJECTIVES:

To assess the accuracy of routine blood-based laboratory tests to predict mortality and deterioration to severe or critical (from mild or moderate) COVID-19 in people with SARS-CoV-2. SEARCH

METHODS:

On 25 August 2022, we searched the Cochrane COVID-19 Study Register, encompassing searches of various databases such as MEDLINE via PubMed, CENTRAL, Embase, medRxiv, and ClinicalTrials.gov. We did not apply any language restrictions. SELECTION CRITERIA We included studies of all designs that produced estimates of prognostic accuracy in participants who presented to outpatient services, or were admitted to general hospital wards with confirmed SARS-CoV-2 infection, and studies that were based on serum banks of samples from people. All routine blood-based laboratory tests performed during the first encounter were included. We included any reference standard used to define deterioration to severe or critical disease that was provided by the authors. DATA COLLECTION AND

ANALYSIS:

Two review authors independently extracted data from each included study, and independently assessed the methodological quality using the Quality Assessment of Prognostic Accuracy Studies tool. As studies reported different thresholds for the same test, we used the Hierarchical Summary Receiver Operator Curve model for meta-analyses to estimate summary curves in SAS 9.4. We estimated the sensitivity at points on the SROC curves that corresponded to the median and interquartile range boundaries of specificities in the included studies. Direct and indirect comparisons were exclusively conducted for biomarkers with an estimated sensitivity and 95% CI of ≥ 50% at a specificity of ≥ 50%. The relative diagnostic odds ratio was calculated as a summary of the relative accuracy of these biomarkers. MAIN

RESULTS:

We identified a total of 64 studies, including 71,170 participants, of which 8169 participants died, and 4031 participants deteriorated to severe/critical condition. The studies assessed 53 different laboratory tests. For some tests, both increases and decreases relative to the normal range were included. There was important heterogeneity between tests and their cut-off values. None of the included studies had a low risk of bias or low concern for applicability for all domains. None of the tests included in this review demonstrated high sensitivity or specificity, or both. The five tests with summary sensitivity and specificity above 50% were C-reactive protein increase, neutrophil-to-lymphocyte ratio increase, lymphocyte count decrease, d-dimer increase, and lactate dehydrogenase increase. Inflammation For mortality, summary sensitivity of a C-reactive protein increase was 76% (95% CI 73% to 79%) at median specificity, 59% (low-certainty evidence). For deterioration, summary sensitivity was 78% (95% CI 67% to 86%) at median specificity, 72% (very low-certainty evidence). For the combined outcome of mortality or deterioration, or both, summary sensitivity was 70% (95% CI 49% to 85%) at median specificity, 60% (very low-certainty evidence). For mortality, summary sensitivity of an increase in neutrophil-to-lymphocyte ratio was 69% (95% CI 66% to 72%) at median specificity, 63% (very low-certainty evidence). For deterioration, summary sensitivity was 75% (95% CI 59% to 87%) at median specificity, 71% (very low-certainty evidence). For mortality, summary sensitivity of a decrease in lymphocyte count was 67% (95% CI 56% to 77%) at median specificity, 61% (very low-certainty evidence). For deterioration, summary sensitivity of a decrease in lymphocyte count was 69% (95% CI 60% to 76%) at median specificity, 67% (very low-certainty evidence). For the combined outcome, summary sensitivity was 83% (95% CI 67% to 92%) at median specificity, 29% (very low-certainty evidence). For mortality, summary sensitivity of a lactate dehydrogenase increase was 82% (95% CI 66% to 91%) at median specificity, 60% (very low-certainty evidence). For deterioration, summary sensitivity of a lactate dehydrogenase increase was 79% (95% CI 76% to 82%) at median specificity, 66% (low-certainty evidence). For the combined outcome, summary sensitivity was 69% (95% CI 51% to 82%) at median specificity, 62% (very low-certainty evidence). Hypercoagulability For mortality, summary sensitivity of a d-dimer increase was 70% (95% CI 64% to 76%) at median specificity of 56% (very low-certainty evidence). For deterioration, summary sensitivity was 65% (95% CI 56% to 74%) at median specificity of 63% (very low-certainty evidence). For the combined outcome, summary sensitivity was 65% (95% CI 52% to 76%) at median specificity of 54% (very low-certainty evidence). To predict mortality, neutrophil-to-lymphocyte ratio increase had higher accuracy compared to d-dimer increase (RDOR (diagnostic Odds Ratio) 2.05, 95% CI 1.30 to 3.24), C-reactive protein increase (RDOR 2.64, 95% CI 2.09 to 3.33), and lymphocyte count decrease (RDOR 2.63, 95% CI 1.55 to 4.46). D-dimer increase had higher accuracy compared to lymphocyte count decrease (RDOR 1.49, 95% CI 1.23 to 1.80), C-reactive protein increase (RDOR 1.31, 95% CI 1.03 to 1.65), and lactate dehydrogenase increase (RDOR 1.42, 95% CI 1.05 to 1.90). Additionally, lactate dehydrogenase increase had higher accuracy compared to lymphocyte count decrease (RDOR 1.30, 95% CI 1.13 to 1.49). To predict deterioration to severe disease, C-reactive protein increase had higher accuracy compared to d-dimer increase (RDOR 1.76, 95% CI 1.25 to 2.50). The neutrophil-to-lymphocyte ratio increase had higher accuracy compared to d-dimer increase (RDOR 2.77, 95% CI 1.58 to 4.84). Lastly, lymphocyte count decrease had higher accuracy compared to d-dimer increase (RDOR 2.10, 95% CI 1.44 to 3.07) and lactate dehydrogenase increase (RDOR 2.22, 95% CI 1.52 to 3.26). AUTHORS'

CONCLUSIONS:

Laboratory tests, associated with hypercoagulability and hyperinflammatory response, were better at predicting severe disease and mortality in patients with SARS-CoV-2 compared to other laboratory tests. However, to safely rule out severe disease, tests should have high sensitivity (> 90%), and none of the identified laboratory tests met this criterion. In clinical practice, a more comprehensive assessment of a patient's health status is usually required by, for example, incorporating these laboratory tests into clinical prediction rules together with clinical symptoms, radiological findings, and patient's characteristics.
Assuntos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Proteína C-Reativa / SARS-CoV-2 / COVID-19 Limite: Humans Idioma: En Revista: Cochrane Database Syst Rev Assunto da revista: PESQUISA EM SERVICOS DE SAUDE Ano de publicação: 2024 Tipo de documento: Article País de afiliação: Bélgica

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Proteína C-Reativa / SARS-CoV-2 / COVID-19 Limite: Humans Idioma: En Revista: Cochrane Database Syst Rev Assunto da revista: PESQUISA EM SERVICOS DE SAUDE Ano de publicação: 2024 Tipo de documento: Article País de afiliação: Bélgica
...