Effectiveness and safety of preoperative distraction using modified halo-pelvic Ilizarov distraction assembly in patients with severe kyphoscoliosis.
Ilyas, Muhammad Saad; Shah, Abdullah; Zehra, Uruj; Ismail, Muhammad; Elahi, Haseeb; Aziz, Amer.
Afiliação
  • Ilyas MS; Department of Orthopaedic and Spine Surgery, Ghurki Trust Teaching Hospital, Lahore, Pakistan.
  • Shah A; Department of Orthopaedic and Spine Surgery, Ghurki Trust Teaching Hospital, Lahore, Pakistan.
  • Zehra U; Department of Anatomy, University of Health Sciences, Lahore, Pakistan.
  • Ismail M; Department of Orthopaedic and Spine Surgery, Ghurki Trust Teaching Hospital, Lahore, Pakistan.
  • Elahi H; Department of Orthopaedic and Spine Surgery, Ghurki Trust Teaching Hospital, Lahore, Pakistan.
  • Aziz A; Department of Orthopaedic and Spine Surgery, Ghurki Trust Teaching Hospital, Lahore, Pakistan.
Asian Spine J ; 18(4): 522-531, 2024 Aug.
Article em En | MEDLINE | ID: mdl-39117355
ABSTRACT
STUDY

DESIGN:

A 2-year follow-up study.

PURPOSE:

To evaluate the effectiveness of modified halo-pelvic Ilizarov distraction assembly in the management of patients with severe kyphoscoliosis. OVERVIEW OF LITERATURE Severe and rigid scoliosis curves are always a challenge for operating surgeons. Preoperative correction through halo-pelvic devices successfully minimizes the severity of the curve; however, cumbersome complications are also reported with its use. Modified assembly could be safe for these cases.

METHODS:

Patients with severe kyphoscoliosis having coronal Cobb angle >90° were applied with modified halo-pelvic Ilizarov distraction assembly preoperatively. The modified assembly consisted of a pelvic component and halo ring, and distraction was given at the rate of 2-3 mm/day for 6-12 weeks. Complete clinical assessments along with pulmonary function tests were performed, and scoliosis series X-ray images were assessed for coronal and sagittal Cobb angle and other spinopelvic parameters before applying the assembly and during 2 years of follow-up.

RESULTS:

Thirty-four patients (age, 9-27 years; male/female ratio of 1816) were included. The coronal and sagittal Cobb angles were 116°±16.2° and 84°±28.3°, respectively. Correction rates obtained through modified halo-pelvic assembly were nearly 52% (p=0.001) in coronal and 40% (p=0.001) in sagittal Cobb angles, with improvement in height (p=0.001). Apical vertebral translation and coronal balance were also improved significantly (p=0.001). Further improvements in all the parameters were obtained after definitive surgery, with improvements in the forced expiratory volume in 1 second (p =0.002) and forced vital capacity (p=0.001).

CONCLUSIONS:

Our modified halo-pelvic Ilizarov distraction assembly can achieve good correction in severe spinal deformities without significant risk to neurology, has fewer complications, and promotes good patient compliance.