Your browser doesn't support javascript.
loading
A comparison of multivariate curve resolution with endmember extraction methods in hyperspectral Raman imaging.
Schmidt, Robert W; Ariese, Freek; Omidikia, Nematollah.
Afiliação
  • Schmidt RW; LaserLaB Amsterdam, Department of Physics and Astronomy, Vrije Universiteit Amsterdam, De Boelelaan 1081, 1081 HV Amsterdam, the Netherlands.
  • Ariese F; LaserLaB Amsterdam, Department of Physics and Astronomy, Vrije Universiteit Amsterdam, De Boelelaan 1081, 1081 HV Amsterdam, the Netherlands.
  • Omidikia N; NIOZ Royal Netherlands Institute for Sea Research, Department of Marine Microbiology & Biogeochemistry, 't Horntje (Texel), the Netherlands. Electronic address: nemat.omidikia@nioz.nl.
Spectrochim Acta A Mol Biomol Spectrosc ; 323: 124868, 2024 Dec 15.
Article em En | MEDLINE | ID: mdl-39128307
ABSTRACT
Hyperspectral Raman imaging not only offers spectroscopic fingerprints but also reveals morphological information such as spatial distributions in an analytical sample. However, the spectrum-per-pixel nature of hyperspectral imaging (HSI) results in a vast amount of data. Furthermore, HSI often requires pre- and post-processing steps to extract valuable chemical information. To derive pure spectral signatures and concentration abundance maps of the active spectroscopic compounds, both endmember extraction (EX) and Multivariate Curve Resolution (MCR) techniques are widely employed. The objective of this study is to carry out a systematic investigation based on Raman mapping datasets to highlight the similarities and differences between these two approaches in retrieving pure variables, and ultimately provide guidelines for pure variable extraction. Numerical simulations and Raman mapping experiments on a mixture of pharmaceutical powders and on a layered plastic foil sample were conducted to underscore the distinctions between MCR and EX algorithms (in particular Vertex Component Analysis, VCA) and their outputs. Both methods were found to perform well if the dataset contains pure pixels for each of the individual components. However, in cases where such pure pixels do not exist, only MCR was found to be capable of extracting the pure component spectra.
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Idioma: En Revista: Spectrochim Acta A Mol Biomol Spectrosc Assunto da revista: BIOLOGIA MOLECULAR Ano de publicação: 2024 Tipo de documento: Article País de afiliação: Holanda

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Idioma: En Revista: Spectrochim Acta A Mol Biomol Spectrosc Assunto da revista: BIOLOGIA MOLECULAR Ano de publicação: 2024 Tipo de documento: Article País de afiliação: Holanda
...