Your browser doesn't support javascript.
loading
A new method called MiKneeSoTA to minimize knee soft-tissue artifacts in kinematic analysis.
Einfeldt, Ann-Kathrin; Budde, Leon; Ortigas-Vásquez, Ariana; Sauer, Adrian; Utz, Michael; Jakubowitz, Eike.
Afiliação
  • Einfeldt AK; Laboratory for Biomechanics and Biomaterials, Department of Orthopaedic Surgery, Hannover Medical School, Anna-von-Borries-Str. 1-7, 30625, Hannover, Germany.
  • Budde L; Leibniz Universität Hannover, Institute of Mechatronic Systems, An der Universität 1, 30823, Garbsen, Germany.
  • Ortigas-Vásquez A; Research and Development, Aesculap AG, Am Aesculap-Platz, 78532, Tuttlingen, Germany.
  • Sauer A; Department of Orthopaedic and Trauma Surgery, Musculoskeletal University Center Munich, Campus Grosshadern, Ludwig Maximilians University Munich, Marchioninistraße 15, 81377, Munich, Germany.
  • Utz M; Research and Development, Aesculap AG, Am Aesculap-Platz, 78532, Tuttlingen, Germany.
  • Jakubowitz E; Research and Development, Aesculap AG, Am Aesculap-Platz, 78532, Tuttlingen, Germany.
Sci Rep ; 14(1): 20666, 2024 09 05.
Article em En | MEDLINE | ID: mdl-39237576
ABSTRACT
The use of marker-based optical motion capture to estimate joint kinematics during gait is currently limited by errors associated with soft-tissue-induced motion artefacts (STIMA) and ambiguity in landmark palpation. This study therefore presents a novel protocol aiming to Minimize Knee Soft-Tissue Artefacts (MiKneeSoTA) and their effect on kinematic estimates. Relying on an augmented marker set and a new inverse kinematics approach, our method leverages frame-by-frame optimization to adjust best-fit cylinders that have been automatically generated based on the relative position of lower limb markers during an initial static trial. Tibiofemoral rotations and translations are then calculated along the anatomical joint axes based on the relative 3D motion of these cylinders. When compared against the conventional Helen-Hayes approach, in vivo assessment of fifteen healthy subjects revealed the MiKneeSoTA approach led to kinematic profiles with significantly lower standard deviations in joint rotations across trials, and even visibly reduced the presence of high frequency fluctuations presumably associated with e.g. soft-tissue vibration. In addition to agreeing with previously published bone pin and fluoroscopy datasets, our results illustrate MiKneeSoTA's ability to abate the effect of STIMA induced by lateral knee ligaments. Our findings indicate that MiKneeSoTA is in fact a promising approach to mitigate knee joint STIMA and thus enable the previously unattainable accurate estimation of translational knee joint motion with an optoelectronic system.
Assuntos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Artefatos / Articulação do Joelho Limite: Adult / Female / Humans / Male Idioma: En Revista: Sci Rep Ano de publicação: 2024 Tipo de documento: Article País de afiliação: Alemanha

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Artefatos / Articulação do Joelho Limite: Adult / Female / Humans / Male Idioma: En Revista: Sci Rep Ano de publicação: 2024 Tipo de documento: Article País de afiliação: Alemanha
...