Early external fixation of tibial plateau fractures is associated with an increased risk of compartment syndrome.
Wier, Julian; Duong, Andrew M; Gary, Joshua L; Patterson, Joseph T.
Afiliação
  • Wier J; Department of Orthopaedic Surgery, Keck School of Medicine of the University of Southern California, Los Angeles, CA, USA.
  • Duong AM; Department of Orthopaedic Surgery, Keck School of Medicine of the University of Southern California, Los Angeles, CA, USA.
  • Gary JL; Department of Orthopaedic Surgery, Keck School of Medicine of the University of Southern California, Los Angeles, CA, USA.
  • Patterson JT; Department of Orthopaedic Surgery, Keck School of Medicine of the University of Southern California, Los Angeles, CA, USA. Electronic address: josephp7@usc.edu.
Injury ; 55(11): 111879, 2024 Nov.
Article em En | MEDLINE | ID: mdl-39305834
ABSTRACT

INTRODUCTION:

Tibial plateau fractures are often associated with high-energy trauma necessitating external fixation as a means of temporization. There is evidence that pin placement and fracture distraction may result in transient increases in compartment pressures, and the optimal timing of external fixator placement is unknown. This study sought to determine the effect of early versus late external fixator placement on the risk of compartment syndrome after a tibial plateau fracture.

METHODS:

The Trauma Quality Improvement Program was retrospectively queried between 2015 and 2019 for adult patients with a tibial plateau fracture who underwent external fixator placement. Patients with concomitant tibial shaft and/or distal femur fractures, requiring lower extremity fasciotomy before external fixation, or external fixation >7 days after admission were excluded. The primary study outcome was inpatient compartment syndrome. Secondary outcomes were inpatient acute respiratory failure/unplanned intubation, surgical site infection, and venous thromboembolism (VTE). A time threshold of delayed external fixation was identified at which the odds of compartment syndrome no longer significantly decreased with increasing time using a Markov Chain Monte Carlo simulation of a restricted cubic spline model. The odds of each outcome were compared between patients who underwent early versus delayed external fixation on or after the time threshold, adjusting for potential confounding by patients, injury, and hospital characteristics. Significance was defined as p < 0.05.

RESULTS:

A threshold for delayed external fixation was identified at 28.8 h from admission. Of the 3,185 eligible patients, 2,656 (83.4 %) were classified as early external fixation and 529 (16.6 %) were classified as delayed external fixation. Delayed external fixation was associated with lower adjusted odds (aOR) of compartment syndrome (aOR 0.31, 95 % Confidence Interval (CI) 0.13-0.74, p = 0.008) and higher aOR of acute respiratory failure/unplanned intubation (aOR 2.13, 95 % CI 1.13-4.0.2, p = 0.019), however no significant differences in adjusted odds of surgical site infection or VTE were observed.

CONCLUSION:

Patients with tibial plateau fractures who underwent closed reduction and external fixation within 28.8 h of admission were associated with greater odds of compartment syndrome than those undergoing external fixation after this time threshold.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Fraturas da Tíbia / Fixadores Externos / Síndromes Compartimentais / Fixação de Fratura Limite: Adult / Female / Humans / Male / Middle aged Idioma: En Revista: Injury Ano de publicação: 2024 Tipo de documento: Article País de afiliação: Estados Unidos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Fraturas da Tíbia / Fixadores Externos / Síndromes Compartimentais / Fixação de Fratura Limite: Adult / Female / Humans / Male / Middle aged Idioma: En Revista: Injury Ano de publicação: 2024 Tipo de documento: Article País de afiliação: Estados Unidos
...