Your browser doesn't support javascript.
loading
Biomechanical Gait Analysis Using a Smartphone-Based Motion Capture System (OpenCap) in Patients with Neurological Disorders.
Min, Yu-Sun; Jung, Tae-Du; Lee, Yang-Soo; Kwon, Yonghan; Kim, Hyung Joon; Kim, Hee Chan; Lee, Jung Chan; Park, Eunhee.
Afiliação
  • Min YS; Department of Rehabilitation Medicine, School of Medicine, Kyungpook National University, Daegu 41944, Republic of Korea.
  • Jung TD; Department of Rehabilitation Medicine, Kyungpook National University Chilgok Hospital, Daegu 41404, Republic of Korea.
  • Lee YS; AI-Driven Convergence Software Education Research Program, Graduate School of Computer Science and Engineering, Kyungpook National University, Daegu 41566, Republic of Korea.
  • Kwon Y; Department of Biomedical Engineering, College of Medicine, Seoul National University, Seoul 03080, Republic of Korea.
  • Kim HJ; Department of Rehabilitation Medicine, School of Medicine, Kyungpook National University, Daegu 41944, Republic of Korea.
  • Kim HC; Department of Rehabilitation Medicine, Kyungpook National University Chilgok Hospital, Daegu 41404, Republic of Korea.
  • Lee JC; Department of Rehabilitation Medicine, School of Medicine, Kyungpook National University, Daegu 41944, Republic of Korea.
  • Park E; Department of Rehabilitation Medicine, Kyungpook National University Hospital, Daegu 41944, Republic of Korea.
Bioengineering (Basel) ; 11(9)2024 Sep 12.
Article em En | MEDLINE | ID: mdl-39329653
ABSTRACT
This study evaluates the utility of OpenCap (v0.3), a smartphone-based motion capture system, for performing gait analysis in patients with neurological disorders. We compared kinematic and kinetic gait parameters between 10 healthy controls and 10 patients with neurological conditions, including stroke, Parkinson's disease, and cerebral palsy. OpenCap captured 3D movement dynamics using two smartphones, with data processed through musculoskeletal modeling. The key findings indicate that the patient group exhibited significantly slower gait speeds (0.67 m/s vs. 1.10 m/s, p = 0.002), shorter stride lengths (0.81 m vs. 1.29 m, p = 0.001), and greater step length asymmetry (107.43% vs. 91.23%, p = 0.023) compared to the controls. Joint kinematic analysis revealed increased variability in pelvic tilt, hip flexion, knee extension, and ankle dorsiflexion throughout the gait cycle in patients, indicating impaired motor control and compensatory strategies. These results indicate that OpenCap can effectively identify significant gait differences, which may serve as valuable biomarkers for neurological disorders, thereby enhancing its utility in clinical settings where traditional motion capture systems are impractical. OpenCap has the potential to improve access to biomechanical assessments, thereby enabling better monitoring of gait abnormalities and informing therapeutic interventions for individuals with neurological disorders.
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Idioma: En Revista: Bioengineering (Basel) Ano de publicação: 2024 Tipo de documento: Article