Your browser doesn't support javascript.
loading
A dual-mode homogeneous electrochemical-colorimetric biosensing sensor for carcinoembryonic antigen detection based on a microfluidic paper-based analysis device.
Zhang, Yao; Xu, Jiaqi; Shen, Jianing; Zhang, Bo; Xue, Tianhao; Lv, Xiaoqing; Zhang, Xiaofang; Zhu, Guixian.
Afiliação
  • Zhang Y; School of Instrument Science and Optoelectronic Engineering, Beijing Information Science and Technology University, No. 12 Xiaoying Road, Beijing 100192, China. zhuguixian@bistu.edu.cn.
  • Xu J; School of Instrument Science and Optoelectronic Engineering, Beijing Information Science and Technology University, No. 12 Xiaoying Road, Beijing 100192, China. zhuguixian@bistu.edu.cn.
  • Shen J; School of Instrument Science and Optoelectronic Engineering, Beijing Information Science and Technology University, No. 12 Xiaoying Road, Beijing 100192, China. zhuguixian@bistu.edu.cn.
  • Zhang B; School of Instrument Science and Optoelectronic Engineering, Beijing Information Science and Technology University, No. 12 Xiaoying Road, Beijing 100192, China. zhuguixian@bistu.edu.cn.
  • Xue T; School of Instrument Science and Optoelectronic Engineering, Beijing Information Science and Technology University, No. 12 Xiaoying Road, Beijing 100192, China. zhuguixian@bistu.edu.cn.
  • Lv X; State Key Laboratory of Integrated Optoelectronics, Institute of Semiconductor, Chinese Academy of Sciences, Beijing 100083, China.
  • Zhang X; Department of Clinical Laboratory, Tianjin Medical University General Hospital, Tianjin, 300070, China.
  • Zhu G; School of Instrument Science and Optoelectronic Engineering, Beijing Information Science and Technology University, No. 12 Xiaoying Road, Beijing 100192, China. zhuguixian@bistu.edu.cn.
Anal Methods ; 2024 Oct 01.
Article em En | MEDLINE | ID: mdl-39351625
ABSTRACT
Dual-mode-based sensors have drawn a lot of interest due to their high accuracy and sensitivity compared to single-response systems. A simple electrochemical and colorimetric dual-mode sensor based on enzyme-linked immunosorbent assay (ELISA), without complex electrode surface modification, was developed for accurate and sensitive detection of carcinoembryonic antigen (CEA). The target CEA is recognized by an antibody coupled to horseradish peroxidase (HRP), which then oxidizes the substrate 3,3',5,5'-tetramethylbenzidine (TMB) to generate both a colorimetric and an electrochemical signal. A paper-based analysis device (µPAD) with dual-mode homogeneous sensing microfluidic was created; three paper-based detection areas for colorimetric testing, and a two-electrode embedded detection area for electrochemical testing. When applying colorimetric analysis technology, the linear range of CEA detection is 0.6-40 ng mL-1, and the limit of detection (LOD) is 0.2 ng mL-1. The linear range is 0.1-40 ng mL-1 and the LOD is 0.03 ng mL-1 by applying electrochemical analysis. The visibility and intuitiveness of colorimetry provide a reference for higher sensitivity and quick response of the electrochemical method. A smartphone application (APP) was also developed to realize the dual extraction of colorimetric signals. The colorimetric detection system based on ELISA can provide a new path for the development of electrochemical sensing and makes it have inherent self-verification and self-correction functions and is expected to provide more reliable and accurate detection results.

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Idioma: En Revista: Anal Methods Ano de publicação: 2024 Tipo de documento: Article País de afiliação: China

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Idioma: En Revista: Anal Methods Ano de publicação: 2024 Tipo de documento: Article País de afiliação: China
...