Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters








Database
Language
Publication year range
1.
J Zoo Wildl Med ; 51(4): 948-957, 2021 Jan.
Article in English | MEDLINE | ID: mdl-33480575

ABSTRACT

The evaluation of laboratory blood analytes is an important tool for health assessment in avian medicine. Unfortunately, there is a lack of suitable reference values for many zoo bird species. The goal of the present study was to establish reference intervals for a wide range of blood analytes in healthy black-headed ibis (Threskiornis melanocephalus) kept in a zoologic garden. Lithium heparinized blood samples from 15 individuals were collected, and 18 different clinical chemistry analytes were measured. New are especially the minimum and maximum values for bile acid (2.38-49.4 µmol/L), cholinesterase (439-1260 U/L), vitamin A (0.65-1.70 mg/L), vitamin E (26.3-52.5 mg/L), and capillary zone electrophoresis (prealbumin, 10.2-23.4%; albumin, 35.9-44.1%; A/G ratio, 1.07-1.69; α-, 15.7-20.0%; ß-, 13.5-19.1%; γ-globulin, 6.08-11.3%). The measured values for clinical chemistry, vitamin, electrophoresis, and hematologic analytes are a basis for further studies and for diagnostics and clinical treatment in this ibis species.


Subject(s)
Birds/blood , Blood Glucose , Blood Proteins/chemistry , Electrophoresis/veterinary , Vitamins/blood , Amylases/blood , Animals , Cholesterol/blood , Cholinesterases/blood , Creatine Kinase/blood , Minerals/blood , Triglycerides/blood
2.
Appl Spectrosc ; 74(12): 1530-1539, 2020 Dec.
Article in English | MEDLINE | ID: mdl-32268784

ABSTRACT

Etalon features in infrared spectra of stratified samples, their influence on the interpretation, and methods to circumvent their presence in infrared spectra have been in discussion for decades. This paper focuses on the application of a method originally developed to remove interference fringes in the mid-infrared spectra for far-infrared Fourier transform spectroscopy on thin polymer films. We show that the total transmittance reflectance technique, commonly used for mid-infrared, also works successfully in the far-infrared spectral range where other approaches fail. Experimental spectra obtained by such technique are supported by model calculations and reveal the possibility and limits to obtain almost undisturbed far-infrared spectra which are suitable to determine low-energy vibrations of ionomer salts under certain sample conditions.

SELECTION OF CITATIONS
SEARCH DETAIL