Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 188
Filter
1.
Article in English | MEDLINE | ID: mdl-39056464

ABSTRACT

BACKGROUND AND OBJECTIVE: Peanut allergy (PA) is an IgE-mediated food allergy with variable clinical outcomes. Mild-to-severe symptoms affect various organs and, often, the gastrointestinal tract. The role of intestine-derived IgE antibodies in astrointestinal PA symptoms is poorly understood. This study aimed to examine fecal IgE responses in PA as a novel approach to patient endotyping. METHODS: Feces and serum samples were collected from peanut-allergic and healthy children (n=26) to identify IgE and cytokines using multiplex assays. Shotgun metagenomics DNA sequencing and allergen database comparisons made it possible to identify microbial peptides with homology to known allergens. RESULTS: Compared to controls, fecal IgE signatures showed broad diversity and increased levels for 13 allergens, including food, venom, contact, and respiratory allergens (P<.01-.0001). Overall, fecal IgE patterns were negatively correlated compared to sera IgE patterns in PA patients, with the greatest differences recorded for peanut allergens (P<.0001). For 83% of the allergens recognized by fecal IgE, we found bacterial homologs from PA patients' gut microbiome (eg, thaumatin-like protein Acinetobacter baumannii vs Act d 2, 109/124 aa identical). Compared to controls, PA patients had higher levels of fecal IgA, IL-22, and auto-IgE binding to their own fecal proteins (P<.001). Finally, levels of fecal IgE correlated with abdominal pain scores (P<.0001), suggesting a link between local IgE production and clinical outcomes. CONCLUSION: Fecal IgE release from the intestinal mucosa could be an underlying mechanism of severe abdominal pain through the association between leaky gut epithelia and anticommensal TH2 responses in PA.

2.
Methods Cell Biol ; 138: 151-161, 2017.
Article in English | MEDLINE | ID: mdl-28129842

ABSTRACT

Traditionally, transplantation has been a major experimental procedure to study the development and function of hematopoietic and immune systems. Here, we describe the use of a zebrafish strain lacking definitive hematopoiesis (cmybI181N) for interspecific analysis of hematopoietic and immune cell development. Without conditioning prior to transplantation, allogeneic and xenogeneic hematopoietic progenitor cells stably engraft in adult zebrafish homozygous for the cmyb mutation. This unique animal model can be used to genetically and functionally disentangle universal and species-specific contributions of the microenvironment to hematopoietic progenitor cell maintenance and development.


Subject(s)
Adaptive Immunity/immunology , Hematopoietic Stem Cell Transplantation/methods , Molecular Biology/methods , Zebrafish/immunology , Adaptive Immunity/genetics , Animals , Embryo, Nonmammalian , Hematopoiesis/genetics , Hematopoietic Stem Cells/immunology , Mutation , Proto-Oncogene Proteins c-myb/genetics , Proto-Oncogene Proteins c-myb/immunology , Zebrafish/genetics
3.
Eur Radiol ; 27(5): 1922-1928, 2017 May.
Article in English | MEDLINE | ID: mdl-27595837

ABSTRACT

OBJECTIVES: To identify imaging algorithms and indications, CT protocols, and radiation doses in polytrauma patients in Swiss trauma centres. METHODS: An online survey with multiple choice questions and free-text responses was sent to authorized level-I trauma centres in Switzerland. RESULTS: All centres responded and indicated that they have internal standardized imaging algorithms for polytrauma patients. Nine of 12 centres (75 %) perform whole-body CT (WBCT) after focused assessment with sonography for trauma (FAST) and conventional radiography; 3/12 (25 %) use WBCT for initial imaging. Indications for WBCT were similar across centres being based on trauma mechanisms, vital signs, and presence of multiple injuries. Seven of 12 centres (58 %) perform an arterial and venous phase of the abdomen in split-bolus technique. Six of 12 centres (50 %) use multiphase protocols of the head (n = 3) and abdomen (n = 4), whereas 6/12 (50 %) use single-phase protocols for WBCT. Arm position was on the patient`s body during scanning (3/12, 25 %), alongside the body (2/12, 17 %), above the head (2/12, 17 %), or was changed during scanning (5/12, 42 %). Radiation doses showed large variations across centres ranging from 1268-3988 mGy*cm (DLP) per WBCT. CONCLUSIONS: Imaging algorithms in polytrauma patients are standardized within, but vary across Swiss trauma centres, similar to the individual WBCT protocols, resulting in large variations in associated radiation doses. KEY POINTS: • Swiss trauma centres have internal standardized imaging algorithms for trauma patients • Whole-body CT is most commonly used for imaging of trauma patients • CT protocols and radiation doses vary greatly across Swiss trauma centres.


Subject(s)
Algorithms , Multiple Trauma/diagnostic imaging , Trauma Centers/statistics & numerical data , Clinical Protocols , Emergency Medical Services , Humans , Radiation Dosage , Surveys and Questionnaires , Switzerland , Tomography, X-Ray Computed/methods , Whole Body Imaging/methods
5.
Br J Dermatol ; 160(4): 782-5, 2009 Apr.
Article in English | MEDLINE | ID: mdl-19210504

ABSTRACT

BACKGROUND: Psychological stress causes phenotypic changes in circulating lymphocytes and is regarded as an important trigger of the Th1-polarized inflammatory skin disease psoriasis. OBJECTIVE: To study the effects of psychological stress on immunological parameters, i.e. membrane molecules relevant to the pathophysiology of psoriasis, especially cutaneous lymphocyte-associated antigens (CLA) involved in T and natural killer (NK) cells homing in on the skin. METHODS: The severity of psoriasis was assessed in patients using the Psoriasis Area and Severity Index. Patients with psoriasis (n=15) and healthy volunteers (n=15) were exposed to brief psychological stress in the laboratory. In vitro analyses were conducted 1 h before, immediately following and 1 h after stress exposure. Peripheral T- and NK-cell subsets including CD8+ T lymphocytes, CLA+ lymphocytes and lymphocyte function-associated antigen type 1 (LFA-1)+ lymphocytes were analysed by flow cytometry. RESULTS: We found a significant stress-induced increase of CD3+ T lymphocytes in patients with psoriasis only. Analyses of T-cell subsets revealed that this increase was observable for cytotoxic CD8+ T lymphocytes and CLA+ CD3+ lymphocytes. The total number of circulating NK cells (CD16+, CD56+) increased immediately after stress in both groups whereas only patients with psoriasis showed a significant increase in CLA+ NK cells. CONCLUSIONS: A higher stress-induced increase of CLA+ T and CLA+ NK cells in the circulation of patients with psoriasis might point to an increased ability of T and NK cells in the presence of psoriasis to home in on the skin during mental stress. Further studies are needed to verify these relationships in more detail and to investigate the time point at which these cells accumulate within lesional skin, and whether or not psychotherapy improves the quality of life of patients with psoriasis and influences stress-dependent parameters.


Subject(s)
Psoriasis/psychology , Skin/immunology , Stress, Psychological/immunology , Female , Humans , Immunity, Cellular , Killer Cells, Natural/immunology , Lymphocyte Activation/immunology , Male , Psoriasis/immunology , Severity of Illness Index , T-Lymphocyte Subsets/immunology , Th1 Cells/immunology
7.
Rofo ; 178(10): 1007-13, 2006 Oct.
Article in German | MEDLINE | ID: mdl-16894497

ABSTRACT

PURPOSE: To evaluate the influence of the body mass index (BMI) on coronary artery opacification in 64-slice CT. MATERIAL AND METHODS: Sixty-two patients retrospectively underwent ECG-gated 64-slice CT coronary angiography (tube potential 120 kV, tube current time product 650 mAs) after intravenous injection of 80 ml of iodinated contrast agent (320 mg/ml, 5 ml/s). Attenuation values (HU) were measured and contrast-to-noise ratios (CNR) were calculated in the right coronary artery (RCA) and left main artery (LMA). The CNR was defined as the difference between the mean attenuation in the vessel and the mean attenuation in the perivascular fat tissue divided by the image noise in the ascending aorta. The height and weight of the patients at the time of the CT scan were recorded and the BMI was calculated. RESULTS: The mean BMI was 26.2 +/- 3.2 kg/m (2) (range 19.7 - 32.2 kg/m (2)), the mean attenuation in the LMA was 330 +/- 64 HU, and the mean attenuation in the RCA was 309 +/- 68 HU. The CNR in the LMA was 16.7 +/- 3.8, and the CNR in the RCA was 15.9 +/- 3.6. The image noise in the ascending aorta significantly correlated with the BMI (r = 0.36, p < 0.01). A weak negative correlation was found between the BMI and LMA attenuation (r = - 0.28, p < 0.05), whereas no significant correlation was found for the RCA (r = - 0.21, p = 0.12). A significant negative correlation was found between the BMI and the CNR in the RCA (r = - 0.41, p < 0.05) and the LMA (r = - 0.47, p < 0.001). CONCLUSION: With constant scan parameters and a constant contrast medium amount, the CNR in both coronary arteries decreases while the BMI increases. This implies a modification of previously standardized and fixed examinations with respect to individually adapted protocols with variable parameters for CT coronary angiography.


Subject(s)
Body Mass Index , Contrast Media , Coronary Angiography/methods , Radiographic Image Enhancement/methods , Radiographic Image Interpretation, Computer-Assisted/methods , Adult , Aged , Aged, 80 and over , Coronary Angiography/standards , Female , Humans , Male , Middle Aged , Radiographic Image Interpretation, Computer-Assisted/standards , Reference Values , Retrospective Studies , Statistics as Topic
8.
Immunol Invest ; 35(1): 63-74, 2006.
Article in English | MEDLINE | ID: mdl-16531330

ABSTRACT

Porphyromonas gingivalis (P.g) is the primary bacterial agent in many forms of chronic periodontitis. Since polymorphonuclear leukocytes (PMNs) are first-line responders to P.g.- induced inflammation, and fibrinogen is important for in vivo PMN in this disease, we have studied the effect of N-formyl-methionyl-leucyl-phenylalanine (fMLP) (an inflammatory stimulus), P.g. fimbriae and fimbrial peptides (based on FimA, the main structural protein of P.g. fimbriae) on PMN-fibrinogen interactions. Freshly isolated human PMNs were allowed to react with FITC-Fibrinogen and various fimbrial peptides (denoted as FimA followed by amino acid number within whole FimA protein), and FITC-Fibrinogen binding was measured using flow cytometry. Freshly isolated neutrophils were also challenged with Fibrinogen and/or fimbrial peptides to measure IL-8 secretion using ELISA. Our studies show that fibrinogen binding to PMNs is enhanced (p < 0.01) in response to fMLP as well as fimbrial peptides (FimA 61-80) containing the motif LTTE (p < 0.01) in a dose dependent manner but not in response to peptides without that motif. We also observed that fMLP and FimA 61-80 have an additive effect on fibrinogen binding to PMNs (p < 0.05), and fMLP and FimA 171-185 significantly inhibit fMLP-induced fibrinogen binding (p < 0.01). To determine of the role of inflammatory cytokines, we examined IL-8 release from PMNs in response to combinations of P. gingivalis fimbriae, fMLP and fibrinogen. In all cases, IL-8 release increased in a dose-dependent manner (p < 0.05). fMLP-fibrinogen effect on IL-8 release from PMNs was synergistic while fimbriae-fibrinogen effect was additive. In summary, PMN priming by fimbrial peptides facilitates fibrinogen-PMN interaction and may increase inflammation.


Subject(s)
Fimbriae Proteins/pharmacology , N-Formylmethionine Leucyl-Phenylalanine/pharmacology , Neutrophils/drug effects , Peptides/pharmacology , Porphyromonas gingivalis/immunology , Fibrinogen/immunology , Fimbriae Proteins/chemistry , Fimbriae Proteins/immunology , Fimbriae, Bacterial/immunology , Humans , Interleukin-8/metabolism , Neutrophils/immunology , Peptides/chemistry , Peptides/immunology , Recombinant Proteins/immunology
9.
Rofo ; 177(10): 1405-11, 2005 Oct.
Article in English | MEDLINE | ID: mdl-16170710

ABSTRACT

PURPOSE: Multiple trauma patients with clinically suspected pelvic fractures often directly undergo a CT scan. However, the initial portable pelvis film (PPF) for further follow-up is then not available. This study examines whether coronal ultra-thick multiplanar reconstructions from CT data are similar when compared with the initial PPF, thus having the potential to serve as an alternative baseline image. MATERIALS AND METHODS: Initial PPF and coronal ultra-thick multiplanar CT reconstructions of 33 multiple trauma patients with pelvic fractures were retrospectively analyzed by two independent radiologists with regard to image quality, visualization of anatomical landmarks, and diagnostic accuracy. The primary diagnosis of pelvic fractures was made by using thin axial CT images and thin slice coronal and sagittal reconstructions and served as the standard of reference. RESULTS: Coronal ultra-thick multiplanar CT reconstructions were superior to PPF regarding image adjustment (p < 0.02), absence of overlaying structures (p < 0.05), and overall image quality (p < 0.01). Visualization of most anatomical landmarks was similar with both modalities, except of the iliosacral joint and acetabular lines which were more accurately depicted on ultra-thick multiplanar CT reconstructions (p < 0.05). Diagnostic accuracy of coronal ultra-thick CT reconstructions was similar to PPF regarding most fracture types, except of a higher accuracy of coronal ultra-thick CT reconstructions for iliosacral joint and acetabular column fractures (p < 0.05). CONCLUSION: Coronal ultra-thick multiplanar CT reconstructions of the pelvis provide similar image quality and diagnostic accuracy compared to PPF and are therefore suited as alternative baseline image in multiple trauma patients who directly undergo CT.


Subject(s)
Fractures, Bone/diagnostic imaging , Imaging, Three-Dimensional/methods , Multiple Trauma/diagnostic imaging , Pelvic Bones/diagnostic imaging , Pelvic Bones/injuries , Radiographic Image Enhancement/methods , Tomography, X-Ray Computed/methods , Adult , Female , Humans , Male , Prognosis , Reproducibility of Results , Retrospective Studies , Sensitivity and Specificity , X-Ray Film
10.
Rofo ; 177(10): 1436-46, 2005 Oct.
Article in German | MEDLINE | ID: mdl-16170715

ABSTRACT

PURPOSE: The purpose of this study is to prospectively compare intravenous pyelography (IVP) and combined unenhanced and excretory phase multidetector-row CT (MDCT) with respect to image quality, diagnostic certainty and diagnostic concordance with the final clinical diagnosis in patients with painless microhematuria. MATERIALS AND METHODS: Unenhanced MDCT, IVP and excretory phase MDCT were performed in 59 consecutive patients (21 women, 38 men, mean age 56 +/- 19 years, range 23 - 83 years) with painless microhematuria of unknown origin during a single examination with a single contrast media application (100 ml, non-ionic iodinated contrast media). Images were assessed by two experienced urogenital radiologists in consensus for image quality, diagnostic certainty of stone detection, obstruction, parenchymal lesions and morphological distinctive features. Imaging diagnoses of MDCT and IVP were compared with the final clinical diagnoses. In case of failure to detect an relevant pathology, the final clinical diagnosis was established after a mean follow-up period of 18 +/- 6 months (10 months to 2 years). Costs and radiation exposure of IVP and MDCT were compared. RESULTS: MDCT scan performed better than IVP in terms of image quality for all regarded variables. Image quality of MDCT was rated in all parameters as very good or good; the image quality of IVP differed in a wide range. MDCT and IVP reached a sensitivity of 100 % and 50 % for stone detection (n = 14, p = 0.008), respectively. Two bladder stones were not detected by IVU but correctly seen with MDCT. MDCT and IVP were unsatisfactory for detecting transitional cell carcinomas (n = 4, 2 of 4 detected with MDCT, 0 of 4 detected with IVU). One false positive transitional cell carcinoma was detected with IVP, none with MDCT. Additional relevant pathological changes (one teratoma, one abdominal aortic aneurysma and one abscess) were detected using MDCT but missed with IVP. In 38 of 59 patients (64 %) imaging and clinical follow-up over up to 24 months did not reveal any pathology to explain the microhematuria. The costs of the IVP (283 Euro) were lower compared with non-enhanced MDCT (380 Euro) or combined non-enhanced and contrast-enhanced MDCT (560 Euro). The radiation exposure was 23 - 27 mSv for MDCT and 2.3 mSv for IVP. CONCLUSION: MDCT performed better regarding image quality, subjective diagnostic certainty and diagnostic results with respect to stone detection. Since urolithiasis is a frequent cause of painless microhematuria MDCT is recommended as the initial imaging modality rather than IVU.


Subject(s)
Hematuria/diagnostic imaging , Image Enhancement/methods , Tomography, Spiral Computed/methods , Urinary Calculi/diagnostic imaging , Urography/methods , Adult , Aged , Aged, 80 and over , Contrast Media/administration & dosage , Female , Hematuria/etiology , Humans , Imaging, Three-Dimensional/methods , Injections, Intravenous , Male , Middle Aged , Pain/etiology , Reproducibility of Results , Sensitivity and Specificity , Urinary Calculi/complications
11.
J Bone Joint Surg Br ; 87(6): 819-23, 2005 Jun.
Article in English | MEDLINE | ID: mdl-15911666

ABSTRACT

In a prospective, randomised study on the repair of tears of the rotator cuff we compared the clinical results of two suture techniques for which different suture materials were used. We prospectively randomised 100 patients with tears of the rotator cuff into two groups. Group 1 had transosseous repair with No. 3 Ethibond using modified Mason-Allen sutures and group 2 had transosseous repair with 1.0 mm polydioxanone cord using modified Kessler sutures. After 24 to 30 months the patients were evaluated clinically using the Constant score and by ultrasonography. Of the 100 patients, 92 completed the study. No significant statistical difference was seen between the two groups: Constant score, 91% vs 92%; rate of further tear, 18% vs 22%; and revision, 4% vs 4%. In cases of further tear the outcome in group 2 did not differ from that for the intact repairs (91% vs 91%), but in group 1 it was significantly worse (94% vs 77%, p = 0.005). Overall, seven patients had complications which required revision surgery, in four for pain (two in each group) and in three for infection (two in group 1 and one in group 2).


Subject(s)
Rotator Cuff Injuries , Suture Techniques , Sutures , Adult , Aged , Female , Humans , Male , Middle Aged , Prospective Studies , Recurrence , Reoperation , Rotator Cuff/surgery , Surgical Wound Infection/microbiology , Treatment Outcome
14.
J Shoulder Elbow Surg ; 14(1): 6-10, 2005.
Article in English | MEDLINE | ID: mdl-15723007

ABSTRACT

We have assessed the incidence of heterotopic ossification (HO) after primary shoulder joint replacement in 126 shoulders; 58 patients had hemiarthroplasty, and 68 had total shoulder joint replacement. HO developed to a minor extent in 15% of patients (19/126). There was no statistical difference between hemiarthroplasty or total shoulder replacement or between male and female patients. Patients with cuff tear arthropathy were the only group with an increased risk (36.4% [4/11]) of having HO develop. In patients with osteoarthritis, fractures, or rheumatoid arthritis, HO occurred in less than 14.5% (15/115). Nonsteroidal anti-inflammatory drugs (NSAIDs) did not appear to have any effect on HO as in hip replacement, as HO developed in 15.15% of patients having NSAIDs postoperatively and in 15.05% of patients without NSAIDs. Prophylaxis of HO with NSAIDs seems only to be indicated in patients with cuff tear arthropathy.


Subject(s)
Arthroplasty, Replacement/adverse effects , Ossification, Heterotopic/etiology , Shoulder Joint/surgery , Adult , Aged , Aged, 80 and over , Anti-Inflammatory Agents, Non-Steroidal/therapeutic use , Female , Humans , Incidence , Male , Middle Aged , Ossification, Heterotopic/epidemiology , Retrospective Studies , Rotator Cuff Injuries
15.
Rofo ; 176(12): 1734-42, 2004 Dec.
Article in German | MEDLINE | ID: mdl-15573283

ABSTRACT

The initial diagnostic work-up of trauma victims with multiple injuries is currently a combination of conventional radiography (CR), ultrasound (US), and computed tomography (CT). This article reviews the diagnostic quality of the different imaging modalities regarding detection and classification of injuries. CT performs better than US in detecting traumatic lesions of abdominal parenchymal organs. Furthermore, CT is better than CR in detecting therapeutically relevant chest and bone injuries. MSCT may replace CR and US under the condition that it is faster than or at least as fast as the conventional approach to diagnose life threatening injuries. This can be achieved only by changing the work-flow for the entire trauma team including radiologist. Furthermore, certain prerequisites must be fulfilled including integration of a MSCT scanner into the emergency room. An optimized whole body CT protocol for the assessment of trauma victims using MSCT as well as a two-step algorithm for reporting the imaging findings depending on their clinical significance is presented.


Subject(s)
Abdominal Injuries/diagnostic imaging , Craniocerebral Trauma/diagnostic imaging , Multiple Trauma/diagnostic imaging , Spinal Injuries/diagnostic imaging , Thoracic Injuries/diagnostic imaging , Tomography, Spiral Computed/methods , Abdominal Injuries/therapy , Aged , Algorithms , Contrast Media , Craniocerebral Trauma/therapy , Emergency Service, Hospital , Female , Humans , Male , Middle Aged , Multiple Trauma/therapy , Posture , Radiation Dosage , Radiography, Abdominal , Radiography, Thoracic , Rib Fractures/diagnostic imaging , Rib Fractures/therapy , Spinal Injuries/therapy , Thoracic Injuries/therapy , Time Factors , Trauma Severity Indices , Ultrasonography
16.
Rofo ; 176(4): 513-21, 2004 Apr.
Article in English | MEDLINE | ID: mdl-15088175

ABSTRACT

PURPOSE: To determine the impact of retrospectively ECG-gated multi-detector row CT (MDCT) on three-dimensional (3D) visualization of the bronchial tree and virtual bronchoscopy (VB) as compared to non-ECG-gated data acquisition. MATERIALS AND METHODS: Contrast-enhanced retrospectively ECG-gated and non-ECG-gated MDCT of the chest was performed in 25 consecutive patients referred for assessment of coronary artery bypass grafts and pathology of the ascending aorta. ECG-gated MDCT data were reconstructed in diastole using an absolute reverse delay of - 400 msec in all patients. In 10 patients additional reconstructions at - 200 msec, - 300 msec, and - 500 msec prior to the R-wave were performed. Shaded surface display (SSD) and virtual bronchoscopy (VB) for visualization of the bronchial segments was performed with ECG-gated and non-ECG-gated MDCT data. The visualization of the bronchial tree underwent blinded scoring. Effective radiation dose and signal-to-noise ratio (SNR) for both techniques were compared. RESULTS: There was no significant difference in visualizing single bronchial segments using ECG-gated compared to non-ECG-gated MDCT data. However, the total sum of scores for all bronchial segments visualized with non-ECG-gated MDCT was significantly higher compared to ECG-gated MDCT (P < 0.05). The summary scores for visualization of bronchial segments for different diastolic reconstructions did not differ significantly. The effective radiation dose and the SNR were significantly higher with the ECG-gated acquisition technique (P < 0.05). CONCLUSION: The bronchial tree is significantly better visualized when using non-ECG-gated MDCT compared to ECG-gated MDCT. Additionally, non-ECG-gated techniques require less radiation exposure. Thus, the current retrospective ECG-gating technique does not provide any additional benefit for 3D visualization of the bronchial tree and VB.


Subject(s)
Bronchi , Bronchoscopy/methods , Imaging, Three-Dimensional , Radiography, Thoracic , Tomography, X-Ray Computed/methods , Adult , Aged , Aged, 80 and over , Aortic Dissection/diagnostic imaging , Aortic Aneurysm/diagnostic imaging , Coronary Artery Bypass , Data Interpretation, Statistical , Electrocardiography , Female , Humans , Image Processing, Computer-Assisted , Male , Middle Aged , Radiation Dosage
17.
Rofo ; 176(4): 529-37, 2004 Apr.
Article in English | MEDLINE | ID: mdl-15088177

ABSTRACT

PURPOSE: To evaluate the time-effectiveness, inter-observer variance, and accuracy of left ventricular ejection fraction (EF) measurements using retrospectively ECG-gated four-channel multi-detector row CT (MDCT) angiography in comparison with biplane cine-ventriculography. MATERIALS AND METHODS: Twenty consecutive patients underwent retrospectively ECG-gated MDCT angiography and conventional coronary angiography with biplane ventriculography. Raw MDCT data were reconstructed at 0 % - 90 % of the cardiac cycle in increments of 10 %. Ten geometrically identical multiplanar reformations parallel to the short axis of the heart were reconstructed in each patient. Three blinded readers segmented the left ventricle in the end-systolic and end-diastolic phase using standardized window settings in order to determine the EF. The EF was measured with biplane cine-ventriculography by two blinded readers and was compared with MDCT. The time needed for post-processing was recorded and the inter-observer agreement for both imaging techniques was assessed. RESULTS: Mean post-processing time was 63 +/- 3 min per patient for MDCT and 5.5 +/- 1.2 min for ventriculography. MDCT and ventriculography showed a good correlation (r = 0.83, p < 0.0001) for measurement of the EF. Mean errors of EF measurements for the three MDCT readers compared with the mean of the ventriculography were - 6.3 +/- 6.6 %, - 4.7 +/- 7.1 % and - 4.6 +/- 5.7 %, respectively. The mean differences between the three readers assessing MDCT were - 1.6 +/- 3.2 % (reader 1 versus 2, r = 0.96), - 1.6 +/- 5.6 % (1 versus 3, r = 0.95) and - 0.011 +/- 2.9 % (2 versus 3, r = 0.97, p < 0.0001). The mean differences between the two readers assessing ventriculography was 0.32 +/- 5.1 % (r = 0.88, p < 0.0001). CONCLUSIONS: MDCT correlates well with biplane cine-ventriculography but has the tendency to underestimate the left ventricular EF. Measurements using MDCT have a high inter-observer agreement, however, the time needed for additional MDCT data post-processing is still unacceptably long.


Subject(s)
Angiography/methods , Stroke Volume , Tomography, X-Ray Computed/methods , Ventricular Function, Left , Aged , Algorithms , Coronary Angiography , Electrocardiography , Female , Forecasting , Heart Rate , Humans , Male , Middle Aged , Observer Variation , Retrospective Studies , Time Factors
18.
Rofo ; 176(4): 556-63, 2004 Apr.
Article in English | MEDLINE | ID: mdl-15088181

ABSTRACT

PURPOSE: To evaluate the impact of different iodine concentrations of intravenous contrast agent on hepatic and vascular enhancement during arterial and porto-venous phase imaging using a 4-channel multi-detector row CT (MDCT). MATERIAL AND METHODS: One hundred consecutive patients referred for triphasic abdominal MDCT were randomly assigned into four groups receiving different iodine concentration (200, 250, 300 or 350 mg/ml). Non-contrast, arterial, and porto-venous phase 4-channel MDCT imaging was performed (VolumeZoom, Siemens, Germany). A fixed volume of 150 ml intravenous contrast agent at a rate of 3 ml/s was injected using an automatic bolus-tracking system (Care Bolus, Siemens, Erlangen). Hepatic and vascular enhancement values were measured over time and non-contrast values were subtracted in order to compute arterial and porto-venous mean hepatic (MHE) and mean aortic (MAE) enhancement for each group. Mean change of enhancement > 80 HU for the aorta and > 40 HU for the liver during porto-venous phase imaging was considered as sufficient enhancement. RESULTS: All groups achieved sufficient vascular enhancement during arterial phase imaging; MAE with 350 mg/ml (222 HU) and 300 mg/ml (213HU) was significantly better than with 250 mg (196HU) and 200 mg/ml (169 HU), whereas MHE showed no statistically significant difference between the groups (range 16 - 25 HU). Porto-venous MHE showed increased enhancement with larger concentrations, with significant differences among the groups. Only the higher concentration groups (350 mg/ml und 300 mg/ml) fulfilled in every individual the guidelines for sufficient porto-venous MHE. In the lower concentration groups, 8 patients with 200 mg/ml and 3 patients with 250 mg/ml showed enhancement values below the required minimum. CONCLUSION: A decrease in iodine contrast agent down to 200 mg/ml concentration is only tenable for propose of vascular aortic and hepatic arterial enhancement, whereas hepatic porto-venous phase imaging still requires concentrations at or above the level of 300 mg/ml.


Subject(s)
Aortography , Contrast Media/administration & dosage , Iodine/administration & dosage , Liver/diagnostic imaging , Radiography, Abdominal , Tomography, X-Ray Computed/methods , Triiodobenzoic Acids/administration & dosage , Adult , Aged , Aged, 80 and over , Analysis of Variance , Aortography/methods , Data Interpretation, Statistical , Female , Humans , Injections, Intravenous , Male , Middle Aged , Prospective Studies , Radiography, Abdominal/methods , Time Factors
19.
Z Orthop Ihre Grenzgeb ; 142(2): 228-34, 2004.
Article in German | MEDLINE | ID: mdl-15106069

ABSTRACT

AIM: The functional long-term results of reconstructions of massive rotator cuff tears (Bateman IV) were evaluated and analyzed. METHODS: 38 patients (6 female/32 male) had a clinical and sonographical assessment and an evaluation of the Constant score after a follow-up of 81 (60 - 160) months. Operative procedures were direct transosseous refixation in 16, local tendon shifts in 17 and deltoid flaps in 5 patients. RESULTS: The average age and sex related Constant score was 77 %. The 5 patients with the deltoid flap achieved a Constant score of 60 %, all had a sonographically detected re-tear and 4 of them rated their result as only moderate. 25/33 patients with reconstruction (76 %) rated their result as good or excellent, 5 (15 %) as satisfactory, 1 (3 %) as moderate and 2 (6 %) as poor. 12 (36 %) of the 33 patients met the sonographic criteria of a re-tear. These patients had a Constant score of 71 %, whereas 21 (64 %) patients with intact reconstruction achieved a score of 85 %. CONCLUSION: The reconstruction of massive rotator cuff tears achieves good clinical long-term results if the tendons remain intact. But even with a recurrent defect, the results have been better than in patients treated with a deltoid flap. In massive rotator cuff tears a thorough selection of the operative procedure regarding atrophy and fatty infiltration of the rotator cuff muscles as well as the tendon retraction and quality is mandatory.


Subject(s)
Orthopedic Procedures/methods , Rotator Cuff Injuries , Rotator Cuff/surgery , Shoulder Pain/diagnosis , Surgical Flaps , Tendon Injuries/diagnosis , Tendon Injuries/surgery , Adult , Aged , Female , Humans , Longitudinal Studies , Middle Aged , Range of Motion, Articular , Recovery of Function , Rotator Cuff/diagnostic imaging , Severity of Illness Index , Shoulder Injuries , Shoulder Joint/diagnostic imaging , Shoulder Joint/surgery , Shoulder Pain/etiology , Tendon Injuries/complications , Tendon Injuries/diagnostic imaging , Ultrasonography
20.
Schmerz ; 18(6): 475-80, 2004 Dec.
Article in German | MEDLINE | ID: mdl-15034776

ABSTRACT

Surgical procedures in the region of the shoulder joint are among the most painful interventions in orthopedic practice. For this reason, in addition to intravenous pain therapy with opioids, blockade of the brachial plexus has become established as an effective method to provide analgesia.High-resolution ultrasound offers the possibility of performing nerve blockades under visual monitoring. Studies on interscalene blockade performed under sonographic control provide evidence for both the high efficacy and safety of the procedure. Clinically manifest signs of nerve damage have not appeared with use of this method. Smaller operations can usually be adequately managed with perioperative single-shot blockade. More extensive operations for which severe pain lasting for several days can be expected and surgical interventions involving preexistent shoulder stiffness necessitate catheterization for uninterrupted pain therapy. Successful rehabilitation after shoulder surgery requires diligent perioperative pain blockade, which can primarily be provided by interscalene plexus blockade.


Subject(s)
Pain, Postoperative/therapy , Shoulder Joint/surgery , Humans , Pain, Postoperative/prevention & control , Shoulder Joint/diagnostic imaging , Ultrasonography
SELECTION OF CITATIONS
SEARCH DETAIL