Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 28
Filter
2.
Vaccines (Basel) ; 11(10)2023 Oct 19.
Article in English | MEDLINE | ID: mdl-37897015

ABSTRACT

Assessing immune responses post-SARS-CoV-2 vaccination is crucial for optimizing vaccine strategies. This prospective study aims to evaluate immune responses and breakthrough infection in 235 infection-naïve healthcare workers up to 13-15 months after initial vaccination in two vaccine groups (108 BNT/BNT/BNT and 127 ChAd/ChAd/BNT). Immune responses were assessed using the interferon-gamma enzyme-linked immunospot (ELISPOT) assay, total immunoglobulin, and neutralizing activity through surrogate virus neutralization test at nine different time points. Both groups exhibited peak responses one to two months after the second or third dose, followed by gradual declines over six months. Notably, the ChAd group exhibited a gradual increase in ELISPOT results, but their antibody levels declined more rapidly after reaching peak response compared to the BNT group. Six months after the third dose, both groups had substantial cellular responses, with superior humoral responses in the BNT group (p < 0.05). As many as 55 breakthrough infection participants displayed higher neutralization activities against Omicron variants, but similar cellular responses compared to 127 infection-naïve individuals, suggesting cross-immunity. Distinct neutralization classifications (<30%, >80% inhibition) correlated with different ELISPOT results. Our study reveals diverse immune response patterns based on vaccine strategies and breakthrough infections, emphasizing the importance of understanding these dynamics for optimized vaccination decisions.

3.
HLA ; 100(1): 52-58, 2022 07.
Article in English | MEDLINE | ID: mdl-35484951

ABSTRACT

The effects of COVID-19 vaccination on alloimmunization and clinical impact in transplant candidates remain largely unknown. In a 61-year-old man who had no donor-specific antibodies (DSA) and was planned to undergo ABO-incompatible kidney transplantation (ABOi KT), DSAs (anti-A24, anti-B51, and anti-Cw14) developed after COVID-19 vaccination. After desensitization therapy, antibody level was further increased, leading to flow cytometric crossmatch-positive status. Donor-specific T cell immunity using interferon-gamma ELISPOT was continuously negative, whereas SARS-CoV-2 specific T cell immunity was intact. After confirming the C1q-negative status of DSA, the patient received ABOi KT. The patient had stable graft function and suppressed alloimmunity up to 2 months after KT. COVID-19 vaccination might relate to alloimmunization in transplant candidates, and desensitization through immune monitoring can help guide transplantation.


Subject(s)
COVID-19 , Kidney Transplantation , Alleles , Antibodies , COVID-19 Vaccines , Flow Cytometry , Graft Rejection , Graft Survival , HLA Antigens , Humans , Living Donors , Male , Middle Aged , SARS-CoV-2 , Vaccination
4.
Clin Biochem ; 104: 59-61, 2022 Jun.
Article in English | MEDLINE | ID: mdl-35131261

ABSTRACT

IgE multiple myeloma is a rare subtype of myeloma, accounting for <0.1% of all myeloma cases. Difficulties in diagnosing and monitoring this rare myeloma type are recognized, including the need of heightened awareness for initial diagnosis, performing a reflex immunofixation test using an anti-IgE antisera, and recognizing the possibility of the prozone phenomenon. Here, we report a rare case of IgE multiple myeloma with the prozone phenomenon. This case was characterized by a paradoxical increase in IgE levels with a progressive increase in the dilution factor. Moreover, serial monitoring of IgE levels correlated with the trend in the serum free light chain ratio, especially when the monoclonal protein was no longer detectable. This case highlights the need for laboratory professionals to be vigilant about the occurrence of the prozone phenomenon in IgE multiple myeloma.


Subject(s)
Multiple Myeloma , Humans , Immunoelectrophoresis , Immunoglobulin E , Immunoglobulin Light Chains , Multiple Myeloma/diagnosis
5.
J Clin Lab Anal ; 36(2): e24222, 2022 Feb.
Article in English | MEDLINE | ID: mdl-34994992

ABSTRACT

INTRODUCTION: Multiple allergen simultaneous test (MAST) is widely used as a screening tool for allergic diseases and has the advantage of providing specific IgE (sIgE) results for various allergens in semiquantitative class. We have continuously conducted external quality assessment (EQA) since 2012 for clinical laboratories performing MAST using AdvanSure allergy screen test (LG CHEM, Korea). This study provides an account of the EQA experience. METHODS: Samples were prepared using pooled sera collected from patients with suspected allergic disease and sent to each laboratory twice a year. Each round included 4-6 serum samples with sIgE for 10-20 inhaled or food allergens. The acceptable class value was the most frequently reported MAST class ±1 titer that exceeded 80% of the total laboratory results. RESULTS: The average number of participating laboratories was 76 (49-90) and the average response rate was 97.3% during the entire survey period. The acceptable rates were consistently high at 97.7% ± 3.7%. Of the total 537 trials, 18 trials (3.4%) were regarded as nonconsensus results, in which acceptable answers did not exceed 80%. For unacceptable results, the false-negative rate (1.5% ± 2.8%) was higher than the false-positive rate (0.8% ± 2.7%) (p < 0.001). MAST class results were correlated with quantitative IgE results by ImmunoCAP (Spearman's correlation coefficient of 0.682 (p < 0.001) and gamma index of 0.777 (p < 0.001). CONCLUSION: Although EQA for MAST showed a high level of acceptable answer, some allergen assays require harmonization. Continuous performance of systematic EQA is needed to improve the accuracy of sIgE assays and quality control in clinical laboratories.


Subject(s)
Allergens/blood , Hypersensitivity/diagnosis , Immunoglobulin E/blood , Quality Assurance, Health Care , Clinical Laboratory Techniques , Diagnostic Errors/statistics & numerical data , Food Hypersensitivity/diagnosis , Food Hypersensitivity/immunology , Humans , Hypersensitivity/immunology , Luminescent Measurements , Republic of Korea
6.
Diagnostics (Basel) ; 11(8)2021 Aug 19.
Article in English | MEDLINE | ID: mdl-34441430

ABSTRACT

Quantitative SARS-CoV-2 antibody assays against the spike (S) protein are useful for monitoring immune response after infection or vaccination. We compared the results of three chemiluminescent immunoassays (CLIAs) (Abbott, Roche, Siemens) and a surrogate virus neutralization test (sVNT, GenScript) using 191 sequential samples from 32 COVID-19 patients. All assays detected >90% of samples collected 14 days after symptom onset (Abbott 97.4%, Roche 96.2%, Siemens 92.3%, and GenScript 96.2%), and overall agreement among the four assays was 91.1% to 96.3%. When we assessed time-course antibody levels, the Abbott and Siemens assays showed higher levels in patients with severe disease (p < 0.05). Antibody levels from the three CLIAs were correlated (r = 0.763-0.885). However, Passing-Bablok regression analysis showed significant proportional differences between assays and converting results to binding antibody units (BAU)/mL still showed substantial bias. CLIAs had good performance in predicting sVNT positivity (Area Under the Curve (AUC), 0.959-0.987), with Abbott having the highest AUC value (p < 0.05). SARS-CoV-2 S protein antibody levels as assessed by the CLIAs were not interchangeable, but showed reliable performance for predicting sVNT results. Further standardization and harmonization of immunoassays might be helpful in monitoring immune status after COVID-19 infection or vaccination.

7.
Ann Lab Med ; 41(6): 577-587, 2021 Nov 01.
Article in English | MEDLINE | ID: mdl-34108285

ABSTRACT

BACKGROUND: Severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) antibody assays have high clinical utility in managing the pandemic. We compared antibody responses and seroconversion of coronavirus disease 2019 (COVID-19) patients using different immunoassays. METHODS: We evaluated 12 commercial immunoassays, including three automated chemiluminescent immunoassays (Abbott, Roche, and Siemens), three enzyme immunoassays (Bio-Rad, Euroimmun, and Vircell), five lateral flow immunoassays (Boditech Med, SD biosensor, PCL, Sugentech, and Rapigen), and one surrogate neutralizing antibody assay (GenScript) in sequential samples from 49 COVID-19 patients and 10 seroconversion panels. RESULTS: The positive percent agreement (PPA) of assays for a COVID-19 diagnosis ranged from 84.0% to 98.5% for all samples (>14 days after symptom onset), with IgM or IgA assays showing higher PPAs. Seroconversion responses varied across the assay type and disease severity. Assays targeting the spike or receptor-binding domain protein showed a tendency for early seroconversion detection and higher index values in patients with severe disease. Index values from SARS-CoV-2 binding antibody assays (three automated assays, one LFIA, and three EIAs) showed moderate to strong correlations with the neutralizing antibody percentage (r=0.517-0.874), and stronger correlations in patients with severe disease and in assays targeting spike protein. Agreement among the 12 assays was good (74.3%-96.4%) for detecting IgG or total antibodies. CONCLUSIONS: Positivity rates and seroconversion of SARS-CoV-2 antibodies vary depending on the assay kits, disease severity, and antigen target. This study contributes to a better understanding of antibody response in symptomatic COVID-19 patients using currently available assays.


Subject(s)
Antibodies, Viral/analysis , COVID-19 Testing/methods , COVID-19/diagnosis , SARS-CoV-2/immunology , COVID-19/pathology , COVID-19/virology , Humans , Immunoassay , Immunoglobulin A/analysis , Immunoglobulin G/analysis , Immunoglobulin M/analysis , Reagent Kits, Diagnostic , SARS-CoV-2/isolation & purification , Sensitivity and Specificity , Severity of Illness Index
8.
Hum Immunol ; 82(4): 302-308, 2021 Apr.
Article in English | MEDLINE | ID: mdl-33744026

ABSTRACT

INTRODUCTION: Flow cytometric crossmatch assay (FCXM) is a sensitive cell-based method for evaluating the presence of donor-specific antibodies (DSA) before transplantation. Recently, 96-well tray FCXM protocol (Halifax FCXM) with improved test efficiency has been introduced. The objective of the present study was to assess the performance of Halifax FCXM by correlating with DSA results based on single antigen bead (SAB) assays (virtual crossmatch, VXM). METHODS: A total of 341 FCXMs were evaluated for the detection of HLA-DSA. A positive VXM was defined as having at least one HLA - DSA (HLA-A, B, Cw, DR, DQB1) with ≥ 1000 MFI (mean fluorescence intensity) identified by SAB assay. RESULTS: Of a total 341 cases, 113 showed class I VXM (+) with class I DSA MFI ≥ 1000 exclusively against one or more donor HLA class I antigens (HLA-A, B, Cw), 72 had class I-/II + DSA, and 156 had VXM(-). Halifax T-FCXM showed a sensitivity of 87.6% (99/113) and a specificity of 98.2% (224/228) for detecting class I VXM (+). The concordance between T-FCXM and class I VXM was 94.7% (323/341). Halifax B-FCXM showed a sensitivity of 58.3% (42/72) and a specificity of 98.7% (154/156) for detecting class I-/II + DSAs. The concordance between B-FCXM and class I-/II + VXM was 86.0% (196/228). When we separately analyzed data, B-FCXM detected HLA-DR (+) (68.8%) and HLA-DQ (+) DSAs (71.0%) similarly (P > 0.05). T-FCXM detected 87.6%, 97.2%, and 98.2% of class I DSA-positive cases with MFI values (sumDSA) ≥ 1000, ≥ 3000, and ≥ 5000, respectively. B-FCXM detected 58.3% of class I-II + DSA -positive (≥1000) cases, but detected 76.7% (33/43) and 89.2% (33/37) of class I-II + DSAs if MFI values of sumDSA and immunodominant DSA (iDSA) were above 5000, respectively. Halifax FCXM had sensitivities of 91.5% and 96.2% for detecting VXM (+) having MFI values above 5000 for class I or class II sumDSA and iDSA, respectively. CONCLUSION: Halifax FCXM showed a good correlation, especially with SAB assay-based high MFI DSA or sumDSA. Concurrent application of FCXM with VXM can improve pre-transplant risk assessment and progress organ allocation efficiency.


Subject(s)
Graft Rejection/immunology , HLA Antigens/genetics , Histocompatibility Testing/methods , Isoantibodies/blood , Kidney Transplantation , Liver Transplantation , Flow Cytometry , HLA Antigens/metabolism , Humans , Retrospective Studies , Sensitivity and Specificity
9.
Int J Mol Sci ; 20(21)2019 Oct 30.
Article in English | MEDLINE | ID: mdl-31671661

ABSTRACT

Although natural killer (NK) cell function is a hallmark of hemophagocytic lymphohistiocytosis (HLH), there is no standard method or data on its diagnostic value in adults. Thus, we performed a single-center retrospective study of 119 adult patients with suspected HLH. NK cell function was determined using both flowcytometry-based NK-cytotoxicity test (NK-cytotoxicity) and NK cell activity test for interferon-gamma (NKA-IFNγ). NK cell phenotype and serum cytokine levels were also tested. Fifty (42.0%) HLH patients showed significantly reduced NK cell function compared to 69 non-HLH patients by both NK-cytotoxicity and NKA-IFNγ (p < 0.001 and p = 0.020, respectively). Agreement between NK-cytotoxicity and NKA-IFNγ was 88.0% in HLH patients and 58.0% in non-HLH patients. NK-cytotoxicity and NKA-IFNγ assays predicted HLH with sensitivities of 96.0% and 92.0%, respectively. The combination of NKA-IFNγ and ferritin (>10,000 µg/L) was helpful for ruling out HLH, with a specificity of 94.2%. Decreased NK-cytotoxicity was associated with increased soluble IL-2 receptor levels and decreased CD56dim NK cells. Decreased NKA-IFNγ was associated with decreased serum cytokine levels. We suggest that both NK-cytotoxicity and NKA-IFNγ could be used for diagnosis of HLH. Further studies are needed to validate the diagnostic and prognostic value of NK cell function tests.


Subject(s)
Interferon-gamma/metabolism , Killer Cells, Natural/metabolism , Lymphohistiocytosis, Hemophagocytic/diagnosis , Adult , Aged , Cytotoxicity Tests, Immunologic , Early Diagnosis , Female , Ferritins/metabolism , Flow Cytometry , Humans , Interferon-gamma/blood , Killer Cells, Natural/immunology , Lymphohistiocytosis, Hemophagocytic/immunology , Male , Middle Aged , Retrospective Studies , Sensitivity and Specificity
10.
PLoS One ; 13(11): e0207434, 2018.
Article in English | MEDLINE | ID: mdl-30427941

ABSTRACT

INTRODUCTION: Complement binding activity of donor-specific HLA antibodies (DSA) has been suggested as a new tool to stratify immunologic risk in kidney transplantation (KT). The objective of this study was to evaluate the clinical implication of C1q/C3d binding activity of de novo DSA (dnDSA) in KT recipients. MATERIAL AND METHODS: A total of 161 pretransplant DSA-negative recipients were monitored for dnDSA at the time of biopsy. C1q/C3d binding activities of dnDSA were assessed using C1qScreen assay (One lambda, USA) and Lifecodes C3d detection assay (Immucor, USA), respectively. Clinical outcomes including biopsy-proven antibody mediated rejection (AMR), C4d detection and post-biopsy graft survival were investigated. RESULTS: De-novo DSAs were detected in fifty-four (33.5%) patients (HLA class I only, n = 19; class II only, n = 29; both class I and II, n = 6). Of them, complement binding activities were detected in 26 (48.1%) patients, including 17 C1q+ and 24 C3d+ patients. Both C1q and C3d positivity were associated with increased mean fluorescence intensity values of dnDSA. Complement binding activity of dnDSA enhanced the incidence of AMR (25.0% in C1q-C3d-, 36.4% in C1q+/C3d- or C1q-/C3d+, and 60.0% in C1q+/C3d+ patients) (P <0.001). The incidence of AMR was not different between patients with C1q+ and those with C3d+ dnDSA (64.7%, 11/17 versus 45.8%, 11/24, P = 0.238). In comparison between C1q and C3d assay according to HLA specificity, C1q+ HLA class I ± II dnDSA was the best predictor for AMR (odds ratio: 27.2). C1q+/C3d+ dnDSA was associated with more C4d deposition in allograft tissue and inferior post-biopsy graft survival. Clinical outcomes were not significantly different between C1q+ and C3d+ dnDSA-positive patients. CONCLUSION: Detection of complement binding activity using both C1q and C3d assays can be a further prognostic marker for predicting AMR and allograft outcome in dnDSA+ kidney transplant patients.


Subject(s)
Complement C1q/immunology , Complement C3d/immunology , HLA Antigens/immunology , Kidney Transplantation/adverse effects , Adult , Antibodies/genetics , Antibodies/immunology , Complement C1q/genetics , Complement C3d/genetics , Female , Glomerular Filtration Rate , Graft Rejection/genetics , Graft Rejection/immunology , Graft Survival/genetics , Graft Survival/immunology , HLA Antigens/genetics , Humans , Kidney/immunology , Kidney/pathology , Male , Middle Aged , Risk Factors , Tissue Donors , Transplant Recipients , Transplantation, Homologous/adverse effects
11.
Ann Lab Med ; 38(6): 578-584, 2018 Nov.
Article in English | MEDLINE | ID: mdl-30027702

ABSTRACT

BACKGROUND: Accurate, rapid, and cost-effective screening tests for hepatitis B virus (HBV) and hepatitis C virus (HCV) infection may be useful in laboratories that cannot afford automated chemiluminescent immunoassays (CLIAs). We evaluated the diagnostic performance of a novel rapid automated fluorescent lateral flow immunoassay (LFIA). METHODS: A fluorescent LFIA using a small bench-top fluorescence reader, Automated Fluorescent Immunoassay System (AFIAS; Boditech Med Inc., Chuncheon, Korea), was developed for qualitative detection of hepatitis B surface antigen (HBsAg), antibody to HBsAg (anti-HBs), and antibody to HCV (anti-HCV) within 20 minutes. We compared the diagnostic performance of AFIAS with that of automated CLIAs-Elecsys (Roche Diagnostics GmbH, Penzberg, Germany) and ARCHITECT (Abbott Laboratories, Abbott Park, IL, USA)-using 20 seroconversion panels and 3,500 clinical serum samples. RESULTS: Evaluation with the seroconversion panels demonstrated that AFIAS had adequate sensitivity for HBsAg and anti-HCV detection. From the clinical samples, AFIAS sensitivity and specificity were 99.8% and 99.3% for the HBsAg test, 100.0% and 100.0% for the anti-HBs test, and 98.8% and 99.1% for the anti-HCV test, respectively. Its agreement rates with the Elecsys HBsAg, anti-HBs, and anti-HCV detection assays were 99.4%, 100.0%, and 99.0%, respectively. AFIAS detected all samples with HBsAg genotypes A-F and H and anti-HCV genotypes 1, 1a, 1b, 2a, 2b, 4, and 6. Cross-reactivity with other infections was not observed. CONCLUSIONS: The AFIAS HBsAg, anti-HBs, and anti-HCV tests demonstrated diagnostic performance equivalent to current automated CLIAs. AFIAS could be used for a large-scale HBV or HCV screening in low-resource laboratories or low-to middle-income areas.


Subject(s)
Fluorescent Dyes/chemistry , Hepatitis B Antibodies/blood , Hepatitis B Surface Antigens/blood , Hepatitis C Antibodies/blood , Immunoassay/methods , Automation , Hepatitis B/diagnosis , Hepatitis C/diagnosis , Humans , Sensitivity and Specificity
12.
Ann Lab Med ; 38(4): 355-361, 2018 Jul.
Article in English | MEDLINE | ID: mdl-29611386

ABSTRACT

BACKGROUND: Carcinoembryonic antigen (CEA) is one of the tumor markers available for evaluating disease progression status after initial therapy and monitoring subsequent treatment modalities in colorectal, gastrointestinal, lung, and breast carcinoma. We evaluated the correlations and differences between widely used, automated CEA immunoassays at four different medical laboratories. METHODS: In total, 393 serum samples with CEA ranging from 3.0 to 1,000 ng/mL were analyzed on ADVIA Centaur XP (Siemens Diagnostics, Tarrytown, NY, USA), ARCHITECT i2000sr (Abbott Diagnostics, Abbott Park, IL, USA), Elecsys E170 (Roche Diagnostics, Indianapolis, IN, USA), and Unicel DxI800 (Beckman Coulter, Fullerton, CA, USA), and the results were compared. Deming regression, Passing-Bablok regression, and Bland-Altman analyses were performed to evaluate the data correlation and % differences among these assays. RESULTS: Deming regression analysis of data from Elecsys E170 and UniCel DxI800 showed good correlation (y=3.1615+0.8970x). According to Bland-Altman plot, no statistically significant bias (-1.78 ng/mL [95% confidence interval: -4.02 to 0.46]) was observed between Elecsys E170 and UniCel DxI800. However, the relative differences of CEA concentrations between assays exceeded the acceptable limit of 30%. Regarding the agreement of positivity with cut-off value 5.0 ng/mL, ARCHITECT i2000sr and Elecsys E170 showed the highest agreement (95.2%), whereas ADVIA Centaur XP and ARCHITECT i2000sr showed the lowest agreement (70.7%). CONCLUSIONS: Agreements between automated CEA immunoassays are variable, and individual CEA concentrations may differ significantly between assays. Standardization of serum CEA concentrations and further harmonization are needed.


Subject(s)
Carcinoembryonic Antigen/blood , Immunoassay/methods , Humans , Immunoassay/standards , Reagent Kits, Diagnostic , Reference Values , Regression Analysis
13.
PLoS One ; 12(12): e0189488, 2017.
Article in English | MEDLINE | ID: mdl-29232714

ABSTRACT

Although cytomegalovirus (CMV) specific cell-mediated immunity (CMI) has been suggested as a predictive marker for CMV infection, proper CMI monitoring strategy in CMV-seropositive recipients and optimal method are not defined. The aim of this study was to evaluate two interferon gamma release assays during early post-transplant period as a predictor of the development of CMV infection in CMV-seropositive patients. A total of 124 CMV-seropositive recipients who received kidney transplantation from CMV-seropositive donor were prospectively examined. At pre-transplant and post-transplant 1 and 3 months, CMV-CMIs were tested using QuantiFERON-CMV assay (QF-CMV) and CMV specific T cell ELISPOT against CMV pp65 and IE-1 antigens (pp65-ELISPOT, IE-1-ELISPOT). CMV DNAemia occurred in 16 (12.9%) patients within 3 months after transplant. Post-transplant pp65 or IE-1 ELISPOT response, but not QF-CMV, was significantly associated with CMV DNAemia. The pp65 ELISPOT (cut-off; 30 spots/200,000 cells) and IE-1 ELISPOT (10 spots/200,000 cells) at post-transplant 1 month predicted the risk of post-transplant CMV DNAemia (P = 0.019). Negative predictive values (NPV) for protection from CMV DNAemia in case of positive ELISPOT results were 94.5% (95% CI: 86.9-97.8%) and 97.6% (95% CI: 86.3-99.6%) in pp65-ELISPOT and IE-1-ELISPOT assays, respectively. These results suggest that the variability may exist between CMV ELISPOT assays and QF-CMV, and CMV ELISPOT at post-transplant 1 month can identify the risk of CMV DNAemia in seropositive kidney transplant recipients.


Subject(s)
Cytomegalovirus Infections/diagnosis , Enzyme-Linked Immunosorbent Assay/methods , Interferons/blood , Kidney Transplantation , Adult , Cytomegalovirus/genetics , Cytomegalovirus/immunology , Cytomegalovirus Infections/immunology , DNA, Viral/blood , Female , Humans , Immunosuppressive Agents/therapeutic use , Interferons/immunology , Male , Middle Aged
14.
Oncotarget ; 8(41): 70431-70440, 2017 Sep 19.
Article in English | MEDLINE | ID: mdl-29050291

ABSTRACT

BACKGROUND/AIM: Decreased Natural killer cell activity (NKA) for interferon-gamma production (NKA-IFNγ) has been reported in cancer patients. The aim of this study was to determine the diagnostic performance of NKA-IFNγ for gastric cancer (GC). RESULTS: NKA-IFNγ levels were decreased in 261 GC patients with all stages of tumor compared to those in 48 healthy donors (P < 0.001), and lower levels of NKA-IFNγ were associated with higher GC stages. NKA-IFNγ levels were also associated with clinicopathological parameters including tumor size, depth of invasion, and lymph node metastasis. NKA-INFγ assay had better diagnostic value (AUC = 0.822) compared to serum CEA (0.624) or CA19-9 assay (0.566) (P < 0.001). Using different cut-off levels, serum CEA and CA19-9 showed sensitivities of 6.1-14.2% and 4.2-28.0%, respectively, which were much lower than that of NKA-IFNγ (55.6-66.7%). METHODS: This study included 261 patients with newly diagnosed GC and 48 healthy donors. NKA for IFNγ was determined by enzyme immunoassay after incubation of whole blood, and diagnostic performance was evaluated. CONCLUSIONS: NK cell activities for IFNγ production could be used as a supportive non-invasive tumor marker for GC diagnosis.

15.
Clin Chim Acta ; 464: 113-117, 2017 Jan.
Article in English | MEDLINE | ID: mdl-27864100

ABSTRACT

BACKGROUND: Antimitochondrial antibody (AMA) is a specific serologic marker in primary biliary cirrhosis (PBC). The aim of this study was to evaluate the clinical relevance of combined AMA assays. METHODS: Sera were obtained from 79 patients with PBC and 108 patients with other liver disease. They were tested by indirect immunofluorescence (IIF) using rat kidney/stomach tissue and HEp2 cells as substrate, 4 AMA-M2 assays, anti-sp100, and anti-gp210 assays. RESULTS: Using IIF-AMA with cut-off titer of 1:40, the sensitivity and specificity for PBC were 88.6% and 87.0%, respectively. A cut-off titer of 1:80 improved the specificity to 93.5%. The 4 commercial assay kits using AMA-M2 autoantibodies showed sensitivity of 55.7-79.7% and specificity of 91.7-95.4% with moderate to good agreement. AMA-M2 assays using both native and recombinant E2 antigens had higher sensitivity. ANAs on HEp2 cells, anti-sp100, and anti-gp210 were detected in 67.1%, 13.9-15.2%, and 22.8-27.8% of PBC patients, respectively. Additional AMA-M2 specific assays in IIF-AMA negative and low titer positive (1:40) sera increased the sensitivity and specificity to 88.6% and 90.7%, respectively. CONCLUSIONS: Serological diagnosis for PBC using IIF with high titer cut-off and additional AMA-M2 specific tests by ELISA or LIA in IIF-negative sera should be used.


Subject(s)
Autoantibodies/blood , Autoantibodies/immunology , Autoantigens/immunology , Blood Chemical Analysis/methods , Fluorescent Antibody Technique, Indirect/methods , Liver Cirrhosis, Biliary/blood , Mitochondria/immunology , Adult , Aged , Aged, 80 and over , Animals , Antigens, Nuclear/immunology , Enzyme-Linked Immunosorbent Assay , Female , Humans , Liver Cirrhosis, Biliary/immunology , Male , Middle Aged , Rats
16.
Anticancer Res ; 36(11): 5849-5858, 2016 11.
Article in English | MEDLINE | ID: mdl-27793908

ABSTRACT

Clinical trials are in progress on AZD5363, an inhibitor of protein kinase B (AKT), to assess its effects on the phosphoinositide 3-kinase (PI3K)/AKT/mammalian target of rapamycin (mTOR) pathway. Cells treated with AKT inhibitors have been reported to activate alternative pathways in order to escape growth inhibition. AZD5363-sensitized Hs578T breast cancer cells displayed reduced levels of phosphorylated glycogen synthase kinase 3 beta (pGSK3ß). Interestingly, in AZD5363-treated cells, the level of phosphorylated (activated) AKT (pAKT) increased. Since pAKT positively correlates with cancer growth and survival, we aimed to identify conditions that could reduce AZD5363-induction of pAKT. We examined whether AZD5363 induction of pAKT could be reduced by co-treatment with inhibitors of the PI3K/AKT/mTOR pathway (LY294002, MK-2206, wortmannin, perifosine, rapamycin, everolimus, and temsirolimus). We observed that co-treatment of LY294002 or MK-2206 with AZD5363 reduced the level of pAKT. Since MK-2206 is clinically used, we propose that co-treatment using MK-2206 with AZD5363 would prove beneficial in blocking the AZD5363-induced pAKT signaling pathway. Our findings contribute to the development of AZD5363-based sensitization therapies for patients with cancer.


Subject(s)
Enzyme Inhibitors/pharmacology , Heterocyclic Compounds, 3-Ring/pharmacology , Proto-Oncogene Proteins c-akt/metabolism , Pyrimidines/pharmacology , Pyrroles/pharmacology , Breast Neoplasms/metabolism , Breast Neoplasms/pathology , Cell Line, Tumor , Chromones , Drug Synergism , Humans , Morpholines , Phosphorylation
17.
Anticancer Res ; 36(11): 5859-5866, 2016 11.
Article in English | MEDLINE | ID: mdl-27793909

ABSTRACT

BACKGROUND/AIM: Colchicine (COL) is a well-known and potent microtubule targeting anticancer agent. The purpose of our study was to identify conditions that increase sensitization of COL-resistant cancer cells that overexpress P-glycoprotein (P-gp). MATERIALS AND METHODS: The anti-malarial drugs chloroquine (CHL), mefloquine (MEF) and primaquine (PRI) have been shown to increase sensitization in drug-resistant KBV20C cells via P-gp inhibition. Therefore, we tested whether co-treatment of COL with PRI, CHL or MEF increases sensitivity in COL-resistant KBV20C cells over that of cells treated with COL alone and whether these effects are attributable to P-gp activity. RESULTS: Interestingly, we found that both CHL and PRI, but not MEF, reduced cytotoxicity in KBV20C cells receiving high concentrations of COL, suggesting that the effects of CHL and PRI have specific mechanisms among the anti-malarial drugs. The effects of CHL and PRI were specific to COL-resistant cells, since we did not detect a reduction in cytotoxicity in drug-sensitive parent KB cells. These data suggest that CHL and PRI inhibit the signaling pathways of COL-treated-resistant cells without P-gp inhibition. Furthermore, we studied the molecular mechanisms underlying the effects of COL-CHL co-treatment in KBV20C cells. FACS analysis, annexin V staining and western blot analysis revealed that G2 arrest and apoptosis were lower in cells co-treated with COL and CHL than in cells treated with COL alone. We also found that pH2AX, pHistone H3 and pRb expression was highly reduced in COL-CHL co-treated cells but not in COL-VIB co-treated cells. In addition, expression of the p21 protein, which correlates with drug-resistant phenotypes, increased in cells receiving COL-CHL co-treatment over that of COL-treated cells. CONCLUSION: These results suggest that reduced G2 arrest and apoptosis resulting from COL-CHL co-treatment was attributable to DNA damage and reduced cell cycle progression. These findings provide important information regarding the prevention of COL toxicity in COL-resistant cells and indicate that CHL, PRI and MEF may contribute to sensitization in COL-resistant cells.


Subject(s)
Antimalarials/pharmacology , Colchicine/toxicity , ATP Binding Cassette Transporter, Subfamily B, Member 1/metabolism , Cell Line, Tumor , Drug Resistance, Neoplasm , Histones/metabolism , Humans
18.
Anticancer Res ; 36(4): 1641-8, 2016 Apr.
Article in English | MEDLINE | ID: mdl-27069141

ABSTRACT

The purpose of this study was to identify conditions that would increase the sensitivity of drug-resistant cancer cells. Previously, two anti-malarial drugs, chloroquine (CHL) and primaquine (PRI), showed different sensitization effects for vinblastine (VIB)-resistant cancer cells. Herein, we tested co-treatment of cells with CHL or PRI and other microtubule-targeting cancer drugs, namely, vinorelbine (VIO), paclitaxel (PAC), docetaxel (DOC), vincristine (VIC), or halaven (HAL). We found that PRI sensitized P-glycoprotein (P-gp)-overexpressing drug-resistant KBV20C cells to all six anti-mitotic drugs to a similar extent. CHL had a similar sensitization effect only for co-treatment with PAC, DOC, VIC, and HAL, while the sensitization effect was less marked for co-treatment with VIB or VIO. FACS analysis and western blot analysis revealed that G2arrest and apoptosis showed only a slight increase on co-treatment with VIB or VIO and CHL. We also found that phospho-histone H3 and pRb were markedly increased only by PRI-VIB co-treatment, but not by CHL-VIB co-treatment. This suggests that reduction in the expression of these proteins correlates with decreased G2arrest in CHL-VIB co-treatment. We further compared the effect of another anti-malarial drug, mefloquine (MEF), in combination with the six anti-mitotic drugs. We found that MEF and PRI had similar sensitization effects in co-treatment with these anti-mitotic drugs. PRI and MEF had generally similar sensitization effects in co-treatment with anti-mitotic drugs, suggesting that they do not have any preferred anti-mitotic drug partner in co-treatment. This indicates that only CHL shows specificity in co-treatment with anti-mitotic drugs in resistant cancer cells. Our results may contribute to the choice of anti-mitotic drugs to be used in co-treatment of resistant cancer cells with the anti-malarial drugs, CHL, PRI, and MEF.


Subject(s)
Antimalarials/pharmacology , Antineoplastic Agents/pharmacology , Chloroquine/pharmacology , Drug Resistance, Neoplasm/drug effects , Mitosis/drug effects , Primaquine/pharmacology , ATP Binding Cassette Transporter, Subfamily B, Member 1/metabolism , Cell Line, Tumor , Docetaxel , Humans , Paclitaxel/pharmacology , Taxoids , Vinblastine/analogs & derivatives , Vinblastine/pharmacology , Vinorelbine
19.
Chem Pharm Bull (Tokyo) ; 63(12): 1065-9, 2015.
Article in English | MEDLINE | ID: mdl-26633028

ABSTRACT

Two new glabretal triterpenes, pancastatins A (1) and B (2), were isolated from the immature fruits of Poncirus trifoliata. Their chemical structures were elucidated by spectroscopic analyses including one- and two-dimensional NMR and high-resolution electrospray ionization mass spectrometry. Compounds 1 and 2 exhibited selective cytotoxicity against PANC-1 pancreatic cancer cells under low-glucose stress conditions.


Subject(s)
Antineoplastic Agents, Phytogenic/pharmacology , Fruit/chemistry , Poncirus/chemistry , Triterpenes/pharmacology , Antineoplastic Agents, Phytogenic/chemistry , Antineoplastic Agents, Phytogenic/isolation & purification , Cell Proliferation/drug effects , Cell Survival/drug effects , Dose-Response Relationship, Drug , Glucose/metabolism , Humans , Molecular Conformation , Oxidative Stress , Structure-Activity Relationship , Triterpenes/chemistry , Triterpenes/isolation & purification , Tumor Cells, Cultured
SELECTION OF CITATIONS
SEARCH DETAIL