Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 8 de 8
Filter
Add more filters








Database
Language
Publication year range
1.
Methods Mol Biol ; 2823: 291-310, 2024.
Article in English | MEDLINE | ID: mdl-39052227

ABSTRACT

We present a novel method to determine engagement and specificity of KRAS4B-targeting compounds in vitro. By employing top-down mass spectrometry (MS), which analyzes intact and modified protein molecules (proteoforms), we can directly visualize and confidently characterize each KRAS4B species within compound-treated samples. Moreover, by employing targeted MS2 fragmentation, we can precisely localize each compound molecule to a specific residue on a given KRAS4B proteoform. This method allows us to comprehensively evaluate compound specificity, clearly detect nonspecific binding events, and determine the order and frequency with which they occur. We provide two proof-of-concept examples of our method employing publicly available compounds, along with detailed protocols for sample preparation, top-down MS data acquisition, targeted proteoform MS2 fragmentation, and analysis of the resulting data. Our results demonstrate the concentration dependence of KRAS4B-compound engagement and highlight the ability of top-down MS to directly map compound binding location(s) without disrupting the KRAS4B primary structure. Our hope is that this novel method may help accelerate the identification of new successful targeted inhibitors for KRAS4B and other RAS isoforms.


Subject(s)
Proto-Oncogene Proteins p21(ras) , Proto-Oncogene Proteins p21(ras)/genetics , Proto-Oncogene Proteins p21(ras)/metabolism , Proto-Oncogene Proteins p21(ras)/antagonists & inhibitors , Humans , Mass Spectrometry/methods , Protein Binding , Tandem Mass Spectrometry/methods
2.
Methods Mol Biol ; 2797: 299-322, 2024.
Article in English | MEDLINE | ID: mdl-38570469

ABSTRACT

Prior analysis of intact and modified protein forms (proteoforms) of KRAS4B isolated from cell lines and tumor samples by top-down mass spectrometry revealed the presence of novel posttranslational modifications (PTMs) and potential evidence of context-specific KRAS4B modifications. However, low endogenous proteoform signal resulted in ineffective characterization, making it difficult to visualize less abundant PTMs or perform follow-up PTM validation using standard proteomic workflows. The NCI RAS Initiative has developed a model system, whereby KRAS4B bearing an N-terminal FLAG tag can be stably expressed within a panel of cancer cell lines. Herein, we present a method for combining immunoprecipitation with complementary proteomic methods to directly analyze N-terminally FLAG-tagged KRAS4B proteoforms and PTMs. We provide detailed protocols for FLAG-KRAS4B purification, proteoform analysis by targeted top-down LC-MS/MS, and validation of abundant PTMs by bottom-up LC-MS/MS with example results.


Subject(s)
Proteomics , Tandem Mass Spectrometry , Chromatography, Liquid , Tandem Mass Spectrometry/methods , Proteomics/methods , Protein Processing, Post-Translational , Liquid Chromatography-Mass Spectrometry
3.
Anal Chem ; 96(13): 5223-5231, 2024 04 02.
Article in English | MEDLINE | ID: mdl-38498381

ABSTRACT

Development of new targeted inhibitors for oncogenic KRAS mutants may benefit from insight into how a given mutation influences the accessibility of protein residues and how compounds interact with mutant or wild-type KRAS proteins. Targeted proteomic analysis, a key validation step in the KRAS inhibitor development process, typically involves both intact mass- and peptide-based methods to confirm compound localization or quantify binding. However, these methods may not always provide a clear picture of the compound binding affinity for KRAS, how specific the compound is to the target KRAS residue, and how experimental conditions may impact these factors. To address this, we have developed a novel top-down proteomic assay to evaluate in vitro KRAS4B-compound engagement while assessing relative quantitation in parallel. We present two applications to demonstrate the capabilities of our assay: maleimide-biotin labeling of a KRAS4BG12D cysteine mutant panel and treatment of three KRAS4B proteins (WT, G12C, and G13C) with small molecule compounds. Our results show the time- or concentration-dependence of KRAS4B-compound engagement in context of the intact protein molecule while directly mapping the compound binding site.


Subject(s)
Proteomics , Proto-Oncogene Proteins p21(ras) , Proto-Oncogene Proteins p21(ras)/genetics , Mutation , Binding Sites
4.
Anal Chem ; 93(47): 15728-15735, 2021 11 30.
Article in English | MEDLINE | ID: mdl-34788003

ABSTRACT

Electron transfer dissociation (ETD) is an analytically useful tool for primary structure interrogation of intact proteins, but its utility is limited by higher-order reactions with the products. To inhibit these higher-order reactions, first-generation fragment ions are kinetically excited by applying an experimentally tailored parallel ion parking waveform during ETD (ETD-PIP). In combination with subsequent ion/ion proton transfer reactions, precursor-to-product conversion was maximized as evidenced by the consumption of more than 90% of the 21 kDa Protein G precursor to form ETD product ions. The employment of ETD-PIP increased sequence coverage to 90% from 80% with standard ETD. Additionally, the inhibition of sequential electron transfers was reflected in the high number of complementary ion pairs from ETD-PIP (90%) compared to standard ETD (39%).


Subject(s)
Electrons , Proteins , Electron Transport , Ions , Sequence Analysis
5.
J Proteome Res ; 20(9): 4427-4434, 2021 09 03.
Article in English | MEDLINE | ID: mdl-34379411

ABSTRACT

Previous work employing five SARS-CoV-2 spike protein receptor-binding domain (RBD) constructs, comprising versions originally developed by Mt. Sinai or the Ragon Institute and later optimized in-house, revealed potential heterogeneity which led to questions regarding variable seropositivity assay performance. Each construct was subjected to N-deglycosylation and subsequent intact mass analysis, revealing significant deviations from predicted theoretical mass for all five proteins. Complementary tandem MS/MS analysis revealed the presence of an additional pyroGlu residue on the N-termini of the two Mt. Sinai RBD constructs, as well as on the N-terminus of the full-length spike protein from which they were derived, thus explaining the observed mass shift and definitively establishing the spike protein N-terminal sequence. Moreover, the observed mass additions for the three Ragon Institute RBD constructs were identified as variable N-terminal cleavage points within the signal peptide sequence employed for recombinant expression. To resolve this issue and minimize heterogeneity for further seropositivity assay development, the best-performing RBD construct was further optimized to exhibit complete homogeneity, as determined by both intact mass and tandem MS/MS analysis. This new RBD construct has been validated for seropositivity assay performance, is available to the greater scientific community, and is recommended for use in future assay development.


Subject(s)
COVID-19 , Spike Glycoprotein, Coronavirus , Humans , Protein Binding , Protein Domains , SARS-CoV-2 , Spike Glycoprotein, Coronavirus/genetics , Spike Glycoprotein, Coronavirus/metabolism , Tandem Mass Spectrometry
6.
J Am Soc Mass Spectrom ; 31(9): 1783-1802, 2020 Sep 02.
Article in English | MEDLINE | ID: mdl-32812765

ABSTRACT

The Consortium for Top-Down Proteomics (www.topdownproteomics.org) launched the present study to assess the current state of top-down mass spectrometry (TD MS) and middle-down mass spectrometry (MD MS) for characterizing monoclonal antibody (mAb) primary structures, including their modifications. To meet the needs of the rapidly growing therapeutic antibody market, it is important to develop analytical strategies to characterize the heterogeneity of a therapeutic product's primary structure accurately and reproducibly. The major objective of the present study is to determine whether current TD/MD MS technologies and protocols can add value to the more commonly employed bottom-up (BU) approaches with regard to confirming protein integrity, sequencing variable domains, avoiding artifacts, and revealing modifications and their locations. We also aim to gather information on the common TD/MD MS methods and practices in the field. A panel of three mAbs was selected and centrally provided to 20 laboratories worldwide for the analysis: Sigma mAb standard (SiLuLite), NIST mAb standard, and the therapeutic mAb Herceptin (trastuzumab). Various MS instrument platforms and ion dissociation techniques were employed. The present study confirms that TD/MD MS tools are available in laboratories worldwide and provide complementary information to the BU approach that can be crucial for comprehensive mAb characterization. The current limitations, as well as possible solutions to overcome them, are also outlined. A primary limitation revealed by the results of the present study is that the expert knowledge in both experiment and data analysis is indispensable to practice TD/MD MS.


Subject(s)
Antibodies, Monoclonal , Mass Spectrometry/methods , Proteomics/methods , Animals , Antibodies, Monoclonal/analysis , Antibodies, Monoclonal/chemistry , Antibodies, Monoclonal/genetics , Complementarity Determining Regions/analysis , Complementarity Determining Regions/chemistry , Complementarity Determining Regions/genetics , Humans , Mice
7.
Anal Chem ; 92(15): 10470-10477, 2020 08 04.
Article in English | MEDLINE | ID: mdl-32597636

ABSTRACT

Complete sequence coverage of monospecific antibodies was previously achieved using immobilized aspergillopepsin I in a single LC-MS/MS analysis. Bispecific antibodies are asymmetrical compared to their monospecific antibody counterparts, resulting in a decrease in the concentration of individual subunits. Four standard proteins were used to characterize the effect of a decrease in concentration when using this immobilized enzyme reactor. Low concentration samples resulted in the elimination of large peptide products due to a greater number of enzymatic cleavages. A competitive inhibitor rich in arginine residues reduced the number of enzymatic cleavages to the protein and retained large molecular weight products. The digestion of a bispecific antibody with competitive inhibition of aspergillopepsin I maintained large peptide products better suited for sequence reconstruction, resulting in complete sequence coverage from a single LC-MS/MS analysis.


Subject(s)
Antibodies, Bispecific/chemistry , Aspartic Acid Endopeptidases/metabolism , Enzymes, Immobilized/metabolism , Sequence Analysis, Protein/methods , Amino Acid Sequence , Aspartic Acid Endopeptidases/antagonists & inhibitors , Aspartic Acid Endopeptidases/chemistry , Base Sequence , Enzymes, Immobilized/chemistry
8.
Anal Chem ; 91(21): 13547-13554, 2019 11 05.
Article in English | MEDLINE | ID: mdl-31584792

ABSTRACT

Accurate sequence characterization is essential for the development of therapeutic antibodies by the pharmaceutical industry. Presented here is a methodology to obtain comprehensive sequence analysis of a monoclonal antibody. An enzyme reactor of immobilized Aspergillopepsin I, a highly stable nonspecific protease, was used to cleave reduced antibody subunits into a peptide profile ranging from 1 to 20 kDa. Utilizing the Thermo Orbitrap Fusion's unique instrument architecture combined with state-of-the-art instrument control software allowed for dynamic instrument methods that optimally characterize eluting peptides based on their size and charge density. Using a data-dependent instrument method, both collisional dissociation and electron transfer dissociation were used to fragment the appropriate charge state of analyte peptides. The instrument layout also allowed for scans to be taken in parallel using both the ion trap and Orbitrap concurrently, thus allowing larger peptides to be analyzed in high resolution using the Orbitrap while simultaneously analyzing tryptic-like peptides using the ion trap. We harnessed these capabilities to develop a custom method to optimally fragment the eluting peptides based on their mass and charge density. Using this approach, we obtained 100% sequence coverage of the total antibody in a single chromatographic analysis, enabling unambiguous sequence assignment of all residues.


Subject(s)
Antibodies, Monoclonal/chemistry , Bioreactors , Enzymes, Immobilized/chemistry , Sequence Analysis, Protein/methods , Amino Acid Sequence , Chromatography, Liquid/methods , Mass Spectrometry/methods , Particle Size
SELECTION OF CITATIONS