Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 213
Filter
1.
Regul Toxicol Pharmacol ; 153: 105714, 2024 Oct 03.
Article in English | MEDLINE | ID: mdl-39368536

ABSTRACT

Fragrance chemicals are ubiquitous in cosmetics; however, they have been linked to allergic contact dermatitis. Allergy prevention involves two main strategies. Firstly, consumers are protected by limiting the maximum concentration of fragrance in a given product to avoid inducing allergies. Secondly, consumers who are already sensitized are protected by having the presence of such fragrance communicated to them. In this study, a validated GC-MS method was employed to quantify 26 allergens in 108 products marketed in Saudi Arabia.Additionally, a quantitative risk assessment (QRA) was performed on the studied cosmetics to determine the risk of inducing allergies. The results indicated that most allergens were present at acceptable concentrations, while 19 products carried a risk of inducing allergies. Furthermore, Lilial and Lyral, two prohibited fragrances, were detected in 97 products. It should be emphasized that this is the first study conducted in Saudi Arabia to evaluate the safety of the well-known 26 fragrance allergens. Hence, this study can potentially serve as a regional standard for future research.

2.
Bull Cancer ; 111(10): 980-986, 2024 Oct.
Article in French | MEDLINE | ID: mdl-39266427

ABSTRACT

In response to the French hospital system crisis and the challenges faced by the heads of departments, we have undertaken an initiative to create a community of heads of haematology departments willing to assist each other. Our inaugural seminar, held in January 2023, established the foundational "core" group of heads of department. Throughout 2023, this emerging community has prospered, offering sustained support to peers. In January 2024, we broadened our community to include other heads of departments, following a second seminar gathering 36 participants. During this event, we took the time to exchange thoughts and reflect on our missions. Building on the experience of guest speakers and employing methods of co-development and co-construction in plenary sessions, small-group workshops, and social gathering, we were able to discover and experience the collective intelligence, creativity, strength, and support stemming from such a group. This peer community of heads of departments stands as a powerful tool for management support, whereby personal experiences nourish and enrich the experience of others. We hope that our initiative will inspire heads of departments from other specialties so that, together, we can better work towards our missions as heads of departments and collaborate on rebuilding the hospital "from the bottom up".


Subject(s)
Hematology , Hospital Departments , Humans , France , Hematology/organization & administration , Hospital Departments/organization & administration , Peer Group
3.
J Clin Oncol ; 42(28): 3287-3299, 2024 Oct.
Article in English | MEDLINE | ID: mdl-39167735

ABSTRACT

PURPOSEHuman leukocyte antigen (HLA) mismatching can reduce survival of patients with blood cancer after hematopoietic cell transplantation (HCT). How recent advances in HCT practice, in particular graft-versus-host disease (GVHD) prophylaxis by post-transplantation cyclophosphamide (PTCy), influence HLA risk associations is unknown.PATIENTS AND METHODSThe study included 17,292 unrelated HCTs with 6-locus high-resolution HLA typing, performed mainly for acute leukemia or related myeloid neoplasms between 2016 and 2020, including 1,523 transplants with PTCy. HLA risk associations were evaluated by multivariable Cox regression models, with overall survival (OS) as primary end point.RESULTSOS was lower in HLA mismatched compared with fully matched transplants (hazard ratio [HR], 1.23 [99% CI, 1.14 to 1.33]; P < .001). This was driven by class I HLA-A, HLA-B, HLA-C (HR, 1.29 [99% CI, 1.19 to 1.41]; P < .001) but not class II HLA-DRB1 and HLA-DQB1 (HR, 1.07 [99% CI, 0.93 to 1.23]; P = .19). Class I antigen-level mismatches were associated with worse OS than allele-level mismatches (HR, 1.36 [99% CI, 1.24 to 1.49]; P < .001), as were class I graft-versus-host peptide-binding motif (PBM) mismatches compared with matches (HR, 1.42 [99% CI, 1.28 to 1.59]; P < .001). The use of PTCy improved GVHD, relapse-free survival compared with conventional prophylaxis in HLA-matched transplants (HR, 0.77 [0.66 to 0.9]; P < .001). HLA mismatching increased mortality in PTCy transplants (HR, 1.32 [1.04 to 1.68]; P = .003) similarly as in non-PTCy transplants (interaction P = .43).CONCLUSIONClass I but not class II HLA mismatches, especially at the antigen and PBM level, are associated with inferior survival in contemporary unrelated HCT. These effects are not significantly different between non-PTCy compared with PTCy transplants. Optimized HLA matching should still be considered in modern HCT.


Subject(s)
Graft vs Host Disease , HLA Antigens , Hematologic Neoplasms , Hematopoietic Stem Cell Transplantation , Histocompatibility Testing , Humans , Hematopoietic Stem Cell Transplantation/methods , Hematopoietic Stem Cell Transplantation/adverse effects , Hematopoietic Stem Cell Transplantation/mortality , Hematologic Neoplasms/therapy , Hematologic Neoplasms/mortality , Hematologic Neoplasms/immunology , Middle Aged , Female , Male , Adult , HLA Antigens/immunology , Graft vs Host Disease/immunology , Graft vs Host Disease/prevention & control , Graft vs Host Disease/mortality , Adolescent , Young Adult , Aged , Child , Cyclophosphamide/therapeutic use , Child, Preschool
4.
Molecules ; 29(15)2024 Jul 25.
Article in English | MEDLINE | ID: mdl-39124892

ABSTRACT

Because of the increasing popularity of e-cigarettes, monitoring the e-cigarette market has become important for national health authorities to guarantee safety and quality. In the EU, the Tobacco Products Directive requires emission studies for e-cigarette products. The absence of industry guidelines for studying these emissions and the lack of proper validation in the literature led us to develop and validate a method using the total error approach for the determination of nicotine in e-cigarette aerosols. A commercial vaping device was used to generate aerosols, which were then collected on Cambridge filter pads and measured for nicotine concentration by UHPLC-DAD after extraction. The method was successfully validated by generating accuracy profiles, which show that the ß-expectation tolerance intervals remained below the acceptance limits of ±20%. Within-run repeatability and intermediate precision were considered acceptable since the highest RSD value obtained was below 5%. The method was applied to 15 commercial e-liquids. A complete validation of a method for the analysis of e-cigarette emissions is presented, including several parameters that impact the accuracy and reproducibility. Similar systematic approaches for method development and validation could be used for other e-cigarette emission analysis methods to ensure the reliability of the measurements.


Subject(s)
Aerosols , Electronic Nicotine Delivery Systems , Nicotine , Aerosols/analysis , Nicotine/analysis , Reproducibility of Results , Chromatography, High Pressure Liquid/methods , Vaping
5.
Cancer Immunol Res ; 12(8): 1090-1107, 2024 Aug 01.
Article in English | MEDLINE | ID: mdl-38819256

ABSTRACT

Chimeric antigen receptor (CAR) T cells express an extracellular domain consisting of a single-chain fragment variable (scFv) targeting a surface tumor-associated antigen. scFv selection should involve safety profiling with evaluation of the efficacy/toxicity balance, especially when the target antigen also is expressed on healthy cells. Here, to assess differences in terms of efficacy and on-target/off-tumor effects, we generated five different CARs targeting CD123 by substituting only the scFv. In in vitro models, T cells engineered to express three of these five CD123 CARs were effectively cytotoxic on leukemic cells without increasing lysis of monocytes or endothelial cells. Using the IncuCyte system, we confirmed the low cytotoxicity of CD123 CAR T cells on endothelial cells. Hematotoxicity evaluation using progenitor culture and CD34 cell lysis showed that two of the five CD123 CAR T cells were less cytotoxic on hematopoietic stem cells. Using a humanized mouse model, we confirmed that CD123- cells were not eliminated by the CD123 CAR T cells. Two CD123 CAR T cells reduced tumor infiltration and increased the overall survival of mice in three in vivo models of blastic plasmacytoid dendritic cell neoplasm. In an aggressive version of this model, bulk RNA sequencing analysis showed that these CD123 CAR T cells upregulated genes associated with cytotoxicity and activation/exhaustion a few days after the injection. Together, these results emphasize the importance of screening different scFvs for the development of CAR constructs to support selection of cells with the optimal risk-benefit ratio for clinical development.


Subject(s)
Immunotherapy, Adoptive , Interleukin-3 Receptor alpha Subunit , Receptors, Chimeric Antigen , Single-Chain Antibodies , Xenograft Model Antitumor Assays , Animals , Humans , Interleukin-3 Receptor alpha Subunit/immunology , Mice , Immunotherapy, Adoptive/methods , Single-Chain Antibodies/immunology , Receptors, Chimeric Antigen/immunology , Receptors, Chimeric Antigen/metabolism , Receptors, Chimeric Antigen/genetics , T-Lymphocytes/immunology , Cell Line, Tumor , Cytotoxicity, Immunologic , Mice, SCID
7.
Cancer ; 130(15): 2642-2651, 2024 Aug 01.
Article in English | MEDLINE | ID: mdl-38581695

ABSTRACT

INTRODUCTION: For the majority of patients with acute myeloid leukemia (AML) an allogeneic stem cell transplant (SCT) in first complete remission (CR) is preferred. However, whether the number of courses required to achieve CR has a prognostic impact is unclear. It is unknown which factors remain important in patients requiring more than one course of induction to attain remission. METHODS: This Acute Leukaemia Working Party study from the European Society for Blood and Marrow Transplantation identified adults who received an allograft in first CR from either a fully matched sibling or 10/10 or 9/10 human leucocyte antigen (HLA)-matched unrelated donor (HLA-A, HLA-B, HLA-C, HLA-DR, or HLA-DQ). Univariate and multivariate analyses were undertaken to identify the prognostic impact of one or two courses of induction to attain CR. RESULTS: A total of 4995 patients were included with 3839 (77%) patients attaining a CR following one course of induction chemotherapy (IND1), and 1116 patients requiring two courses (IND2) to attain CR. IND2 as compared to IND1 was a poor prognostic factor in a univariate analysis and remained so in a multivariate Cox model, resulting in an increased hazard ratio of relapse (1.38; 95% confidence interval [CI], 1.16-1.64; p = .0003) and of death (1.27; 95% CI, 1.09-1.47; p = .002). Adverse prognostic factors in a multivariate analysis of the outcomes of patients requiring IND2 included age, FLT3-ITD, adverse cytogenetics, and performance status. Pretransplant measurable residual disease retained a prognostic impact regardless of IND1 or IND2. CONCLUSION: Initial response to chemotherapy as determined by number of courses to attain CR, retained prognostic relevance even following SCT in CR.


Subject(s)
HLA Antigens , Leukemia, Myeloid, Acute , Remission Induction , Siblings , Unrelated Donors , Humans , Male , Middle Aged , Adult , Female , Leukemia, Myeloid, Acute/therapy , Leukemia, Myeloid, Acute/mortality , Prognosis , HLA Antigens/immunology , Adolescent , Young Adult , Aged , Hematopoietic Stem Cell Transplantation/methods , Induction Chemotherapy/methods , Transplantation, Homologous
9.
Molecules ; 29(5)2024 Mar 01.
Article in English | MEDLINE | ID: mdl-38474628

ABSTRACT

The analysis of heroin samples, before use in the protected environment of user centra, could be a supplementary service in the context of harm reduction. Infrared spectroscopy hyphenated with multivariate calibration could be a valuable asset in this context, and therefore 125 heroin samples were collected directly from users and analysed with classical chromatographic techniques. Further, Mid-Infrared spectra were collected for all samples, to be used in Partial Least Squares (PLS) modelling, in order to obtain qualitative and quantitative models based on real live samples. The approach showed that it was possible to identify and quantify heroin in the samples based on the collected spectral data and PLS modelling. These models were able to identify heroin correctly for 96% of the samples of the external test set with precision, specificity and sensitivity values of 100.0, 75.0 and 95.5%, respectively. For regression, a root mean squared error of prediction (RMSEP) of 0.04 was obtained, pointing at good predictive properties. Furthermore, during mass spectrometric screening, 10 different adulterants and impurities were encountered. Using the spectral data to model the presence of each of these resulted in performant models for seven of them. All models showed promising correct-classification rates (between 92 and 96%) and good values for sensitivity, specificity and precision. For codeine and morphine, the models were not satisfactory, probably due to the low concentration of these impurities as a consequence of acetylation. For methacetin, the approach failed.


Subject(s)
Heroin , Heroin/analysis , Calibration , Spectrophotometry, Infrared , Least-Squares Analysis
11.
Contact Dermatitis ; 90(6): 594-606, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38471795

ABSTRACT

INTRODUCTION: Medical devices (MDs) have a long history of use, and come with regulatory frameworks to ensure user safety. Although topically applied MDs in the form of gels and creams might be used on damaged skin, their composition is often similar to that of cosmetic products applicable to intact skin, especially in terms of preservatives and fragrances. However, unlike cosmetics, these products are not subject to compound-specific restrictions when used in MDs. OBJECTIVE: This study aimed to identify and quantify preservatives and fragrances in topically applied MDs and assess their safety towards the Cosmetic Regulation (EC) 1223/2009. METHOD: Sixty-nine MDs available on the EU market were subjected to previously validated liquid chromatography tandem mass spectrometry (LC-MS/MS) and gas chromatography-mass spectrometry (GC-MS) methods to identify and quantify occurring preservatives and fragrances. RESULTS: Findings revealed that 32% of the examined MDs did not provide comprehensive ingredient lists, leaving users uninformed about potential risks associated with product use. Furthermore, 30% of these MDs would not meet safety standards for cosmetic products and, most significantly, 13% of the analysed samples contained ingredients that are prohibited in leave-on cosmetics. CONCLUSION: Results highlight the pressing demand for more stringent requirements regarding the labelling and composition of MDs to enhance patient safety. Improved regulation and transparency can mitigate potential risks associated with the use of topically applied MDs.


Subject(s)
Gas Chromatography-Mass Spectrometry , Preservatives, Pharmaceutical , Preservatives, Pharmaceutical/analysis , Preservatives, Pharmaceutical/adverse effects , Humans , Perfume/adverse effects , Perfume/analysis , Cosmetics/analysis , Cosmetics/adverse effects , Equipment and Supplies/adverse effects , European Union , Tandem Mass Spectrometry , Chromatography, Liquid , Consumer Product Safety/legislation & jurisprudence , Administration, Topical
12.
Drug Test Anal ; 16(10): 1195-1202, 2024 Oct.
Article in English | MEDLINE | ID: mdl-38229238

ABSTRACT

As cannabidiol (CBD) is not considered to be a drug and because of its potential health claims, it is an interesting compound that is often found in cosmetics. However, the safety of CBD, as well as the presence of trace amounts of other phytocannabinoids, including the psychoactive substance ∆9-tetrahydrocannabinol (THC), is still being debated. A robust analytical technique capable of analysing cosmetic products and determining their phytocannabinoid content will be crucial in assessing the safety of these products. This systematic review aims to highlight the current analytical tools that could be used to analyse phytocannabinoids in cosmetics. The ideal method would be able to analyse high levels of CBD in combination with trace levels of THC and their acids. The method should provide good recoveries and accuracies in a variety of matrices while providing information on up-coming phytocannabinoids such as cannabichromene (CBC), cannabigerol (CBG) and cannabinol (CBN). The systematic review approach was based on the Preferred Reporting Items for Systematic review and Meta-Analyses method. The research focused on studies published from January 2010 to December 2022 in PubMed and Scopus. A total of 15 datasets met the inclusion and exclusion criteria and were tabulated to allow easy comparison. Although some of the reviewed methods can handle multiple matrices and provide satisfactory recoveries, this review process did not identify an ideal method. The most suitable methods either could not quantify phytocannabinoid acids or were not sensitive enough to quantify trace levels of psychoactive phytocannabinoids.


Subject(s)
Cannabinoids , Cosmetics , Cannabinoids/analysis , Cosmetics/analysis , Cosmetics/chemistry , Humans , Cannabidiol/analysis
14.
Clin Lymphoma Myeloma Leuk ; 24(4): e130-e137, 2024 04.
Article in English | MEDLINE | ID: mdl-38267355

ABSTRACT

Blastic plasmacytoid dendritic cell neoplasm (BPDCN) is an aggressive myeloid malignancy of the dendritic cell lineage that affects patients of all ages, though the incidence appears to be highest in patients over the age of 60 years. Diagnosis is based on the presence of plasmacytoid dendritic cell precursors expressing CD123, the interleukin-3 (IL-3) receptor alpha, and a distinct histologic appearance. Timely diagnosis remains a challenge, due to lack of disease awareness and overlapping biologic and clinical features with other hematologic malignancies. Prognosis is poor with a median overall survival of 8 to 14 months, irrespective of disease presentation pattern. Historically, the principal treatment was remission induction therapy followed by a stem cell transplant (SCT) in eligible patients. However, bridging to SCT is often not achieved with induction chemotherapy regimens. The discovery that CD123 is universally expressed in BPDCN and is considered to have a pathogenetic role in its development paved the way for the successful introduction of tagraxofusp, a recombinant human IL-3 fused to a truncated diphtheria toxin payload, as an initial treatment for BPDCN. Tagraxofusp was approved in 2018 by the United States Food and Drug Administration for the treatment of patients aged 2 years and older with newly diagnosed and relapsed/refractory BPDCN, and by the European Medicines Agency in 2021 for first-line treatment of adults. The advent of tagraxofusp has opened a new era of precision oncology in the treatment of BPDCN. Herein, we present an overview of BPDCN biology, its diagnosis, and treatment options, illustrated by clinical cases.


Subject(s)
Hematologic Neoplasms , Myeloproliferative Disorders , Skin Neoplasms , Adult , Humans , Middle Aged , Interleukin-3 Receptor alpha Subunit , Interleukin-3/therapeutic use , Hematologic Neoplasms/diagnosis , Hematologic Neoplasms/drug therapy , Precision Medicine , Acute Disease , Myeloproliferative Disorders/pathology , Skin Neoplasms/pathology , Dendritic Cells/pathology , Biology
15.
Drug Test Anal ; 16(1): 99-104, 2024 Jan.
Article in English | MEDLINE | ID: mdl-37173289

ABSTRACT

Whipped cream canisters, also known as nitrous oxide whippets, are traditionally used in the culinary arts to prepare food foams. In recent years, however, these gas canisters have been cracked open and inhaled to produce a "legal" high. Users of these whippets have reported the presence of an oily residue containing metallic particles. This contamination was investigated using liquid chromatography-, gas chromatography- and inductively coupled plasma-mass spectrometry (ICP-MS) and optical emission spectrometry (ICP-OES). The particulate matter was also analyzed by scanning transmission electron microscopy (STEM) combined with energy-dispersive X-ray spectroscopy (EDX). The presence of cyclohexyl isothiocyanate was confirmed at a maximum concentration of 67 µg per whippet. ICP-MS and ICP-OES analysis revealed the presence of mainly iron and zinc, but also, traces of aluminum, chromium, cobalt, nickel, and lead were found. STEM-EDX analysis confirmed the presence of nano-sized particles containing iron and zinc. When simulating inhalation, using the multiple path particle dosimetry model, it was confirmed that these nano-sized particles can reach the deeper parts of the lungs. Most users assume that inhaling a food-grade nitrous oxide whippet for a "legal" high poses no risks. However, this research shows that users are exposed to cyclohexyl isothiocyanate, a substance classified as a respiratory sensitizer. The presence of zinc in the particulate matter could potentially be linked to lung lesions.


Subject(s)
Illicit Drugs , Nitrous Oxide , Gas Chromatography-Mass Spectrometry , Zinc , Iron , Particulate Matter , Isothiocyanates
16.
Drug Test Anal ; 2023 Dec 03.
Article in English | MEDLINE | ID: mdl-38043940

ABSTRACT

In 2019, a global viral pandemic, due to the SARS-CoV-2 virus, broke out. Soon after, the search for a vaccine and/or antiviral medicine began. One of the candidate antiviral medicines tested was ivermectin. Although several health authorities warned the public against the use of this medicine outside clinical trials, the drug was widely used at the end of 2020 and in 2021. Simultaneously, several reports started to emerge demonstrating serious adverse effects after self-medicating with ivermectin. It stands to reason that the self-administration of substandard or falsified (SF) medicines bearing harmful quality deficiencies have contributed to this phenomenon. In order to have a better view on the nature of these harmful quality deficiencies, SF ivermectin samples, intercepted in large quantities by the Belgian regulatory agencies during the period 2021-2022, were analyzed in our official medicines control laboratory. None of the samples (n = 19) were compliant to the quality criteria applicable to medicinal products. These SF products either suffered from a systematic underdosing of the active pharmaceutical ingredient or were severely contaminated with bacteria, two of which were contaminated with known pathogens that cause gastrointestinal illness upon oral intake. In addition to the direct risks of self-medicating with such a product, the improper usage and dosage of ivermectin medication might also facilitate ivermectin tolerance or resistance in parasites. This may have detrimental consequences on a global scale, certainly as the number of newly developed active pharmaceutical ingredients that can safely be used to combat parasites is rather scarce.

17.
Drug Test Anal ; 2023 Dec 12.
Article in English | MEDLINE | ID: mdl-38086368

ABSTRACT

More and more countries and organisations emphasise the value of harm reduction measures in the context of illicit drug use and abuse. One of these measures is drug checking, a preventive action that can represent a quick win by tailored consultation on the risks of substance use upon analytical screening of a submitted sample. Unlike drop-in centres that operate within a fixed setting, enabling drug checking in a harm reduction context at events requires portable, easy to use analytical approaches, operated by personnel with limited knowledge of analytical chemistry. In this case study, four different approaches were compared for the characterisation of 3,4-methylenedioxymethamphetamine samples and this in the way the approaches would be applied today in an event context. The four approaches are mid-infrared (MIR), near-infrared, and Raman spectroscopy, which are today used in drug checking context in Belgium, as well as an electrochemical sensor approach initially developed in the context of law enforcement at ports. The MIR and the electrochemical approach came out best, with the latter allowing for a direct straightforward analysis of the percentage 3,4-methylenedioxymethamphetamine (as base equivalent) in the samples. However, MIR has the advantage that, in a broader drug checking context, it allows to screen for several molecules and so is able to identify unexpected active components or at least the group to which such components belong. The latter is also an important advantage in the context of the growing emergence of new psychotropic substances.

18.
Drug Test Anal ; 2023 Oct 04.
Article in English | MEDLINE | ID: mdl-37793648

ABSTRACT

The availability of cannabidiol (CBD) oil products has increased in recent years. No analytical controls are mandatory for these products leading to uncertainties about composition and quality. In this paper, a methodology was developed to identify the oil matrix and to estimate the CBD content in such samples, using mid-infrared and near-infrared spectroscopy. Different oils were selected based on the information labeled on products and were bought in food stores in order to create a sample set with a variety of matrices. These oils were spiked with CBD to obtain samples with CBD levels from 0% to 20%. The first part of the study was focused on the qualitative analysis of the oil matrix. A classification model, based on Soft Independent Modeling of Class Analogy, was build using the spiked oils to distinguish between the different oil matrices. For both spectroscopic techniques, the sensitivity, the specificity, the accuracy and the precision were equal to 100%. These models were applied to determine the oil matrix of seized samples. The second part of the study was focused on the quantitative estimation of CBD. After determination of CBD in seized samples using gas chromatography-tandem mass spectrometry, partial least square regression (PLS-R) models were built, one for each matrix in the sample set. Both techniques were able to classify unknown oily samples according to their matrix, and although only few samples were available to evaluate the PLS-R models, the approach clearly showed promising results for the estimation of the CBD content in oil samples.

19.
Arch Toxicol ; 97(9): 2453-2461, 2023 09.
Article in English | MEDLINE | ID: mdl-37414884

ABSTRACT

The in chemico direct peptide reactivity assay (DPRA) is validated to assess protein reactivity of chemical compounds, relating to the molecular initiating event of skin sensitization induction. According to OECD TG 442C, the DPRA is technically applicable to test multi-constituent substances and mixtures of known composition, even though limited experimental data are publicly available. First, we assessed the DPRA's predictive capability for individual substances, but at concentrations other than the recommended 100 mM, i.e., based on the LLNA EC3 concentration (Experiment A). Next, the applicability of the DPRA to test unknown mixtures was assessed (Experiment B). Here, the complexity of unknown mixtures was reduced to mixtures containing either two known skin sensitizers with varying potencies, or a combination of a skin sensitizer with a non-skin sensitizer, or multiple non-sensitizers. Experiments A and B revealed that one extremely potent sensitizer (oxazolone) was incorrectly classified as a non-sensitizer when tested at its low EC3 concentration of 0.4 mM instead of the suggested molar excess conditions of 100 mM (Experiments A). For binary mixtures tested in experiments B, the DPRA was able to distinguish all skin sensitizers and the strongest skin sensitizer in the mixture was determinant for the overall peptide depletion of a sensitizer. In conclusion, we confirmed that the DPRA test method can be used efficiently for well-known characterized mixtures. However, when deviating from the recommended testing concentration of 100 mM, caution should be taken in case of negative results, limiting the DPRA's applicability for mixtures of unknown composition.


Subject(s)
Animal Testing Alternatives , Peptides , Animals , Peptides/chemistry , Animal Testing Alternatives/methods
20.
Hemasphere ; 7(5): e861, 2023 May.
Article in English | MEDLINE | ID: mdl-37125257

ABSTRACT

Patients (pts) with asymptomatic low-burden follicular lymphoma (FL) are usually observed at diagnosis. Time to lymphoma treatment (TLT) initiation can however be very heterogeneous and risk factors of progression are poorly studied. Our study evaluated 201 pts with grade 1-3a low-tumor burden FL diagnosed in four French centers between 2010 and 2020 and managed by a watch and wait strategy in real-life settings. After a median follow-up of 4.8 years, the median TLT was 4.2 years (95% confidence interval, 3.1-5.5). On multivariate analysis, elevated lactate dehydrogenase (hazard ratio [HR] = 2.2; P = 0.02), more than 4 nodal areas involved (HR = 1.7; P = 0.02) and more than 1 extranodal involvement (HR = 2.7; P = 0.01) were identified as independent predictors of TLT. The median TLT was 5.8 years for pts with no risk factor, 2.4 years for 1 risk factor, and 1.3 years for >1 risk factors (P < 0.01). In a subanalysis of 75 pts staged with positron emission tomography-computed tomography (PET-CT), total metabolic tumor volume (TMTV) ≥14 cm3 and standardized Dmax (reflecting tumor dissemination) >0.32 m-1 were also associated with shorter TLT (HR = 3.4; P = 0.004 and HR = 2.4; P = 0.007, respectively). In multivariate models combining PET-CT parameters and clinical variables, TMTV remained independent predictor of shorter TLT. These simple parameters could help to identify FL patients initially observed at higher risk of early progression. The role of PET-CT (extranodal sites and PET metrics) in low-burden FL appears promising and warrants further assessment in large cohorts.

SELECTION OF CITATIONS
SEARCH DETAIL