Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 9 de 9
Filter
1.
Article in English | MEDLINE | ID: mdl-36251599

ABSTRACT

Longitudinal epiphyseal bracket of the first metatarsal, also known as first enclosed metatarsal, is a rare congenital disorder characterized by an abnormal development in the length of the first metatarsal ray because of the asymmetric presence of a longitudinal epiphyseal bracket. This causes interruption in the lengthways development of the affected bone, which becomes squat and short, with a trapezoidal or triangular shape, leading to a hallux varus deformity. First enclosed metatarsal occurs in 2% to 14% of all congenital defects in the hands and feet; with bilateralism in 75% of cases and a greater incidence in male patients. The deformity is classified as a differentiation defect; it is frequently associated with abnormalities such as syndactyly or polydactyly. There are different surgical treatments reported in the literature. Most of them are aimed at the excision of the epiphyseal bracket before complete skeletal maturity and frequently in the first year of life to promote a normal lengthways growth of the bone. In this study, the authors present three cases of bilateral first enclosed metatarsal in which the surgical treatment, aimed at lengthening the first metatarsal ray by using the Penning Minifixator, was instead carried out at the end of growth. This different surgical approach allowed the planning of a surgical operation involving both the skeletal structures and the surrounding soft tissue.


Subject(s)
Foot Deformities, Congenital , Hallux Valgus , Hallux Varus , Hallux , Metatarsal Bones , Epiphyses/surgery , Foot Deformities, Congenital/complications , Foot Deformities, Congenital/surgery , Hallux/surgery , Hallux Valgus/etiology , Hallux Varus/surgery , Humans , Male , Metatarsal Bones/abnormalities , Metatarsal Bones/surgery
2.
Hip Int ; 27(6): 551-557, 2017 Nov 21.
Article in English | MEDLINE | ID: mdl-28708200

ABSTRACT

INTRODUCTION: Trabecular Titanium is an advanced cellular solid structure, composed of regular multiplanar hexagonal interconnected cells that mimic the morphology of the trabecular bone. This biomaterial demonstrated improved mechanical properties and enhanced osteoinduction and osteoconduction in several in vitro and in vivo studies. The aim of this study was to assess Trabecular Titanium osseointegration by measuring periacetabular changes in bone mineral density (BMD) with dual-emission X-ray absorptiometry (DEXA). METHODS: 89 patients (91 hips) underwent primary total hip arthroplasty (THA) with acetabular Trabecular Titanium cups. Clinical (Harris Hip Score (HHS), SF-36) and radiographic assessment were performed preoperatively, and postoperatively at 7 days and at 3, 6, 12 and 24 months. DEXA analysis was performed only postoperatively, using the BMD values measured at 7 days as baselines. RESULTS: After an initial decrease from baseline to 6 months, BMD increased and progressively stabilised in all 3 regions of interest (ROIs). Median (IQR) HHS and SF-36 increased from 48 (39-62) and 49 (37-62) preoperatively to 99 (96-100) and 86 (79-92) at 24 months, indicating a considerable improvement in terms of pain relief, functional recovery and quality of life. BMD patterns and radiographic evaluation showed evident signs of periacetabular bone remodelling and osseointegration; all cups were stable at the final follow-up without radiolucent lines, loosening or osteolysis. No revisions were performed. CONCLUSIONS: After an initial reduction in periacetabular BMD, all 3 ROIs exhibited stabilisation or slight recovery. Although clinical outcomes and functional recovery proved satisfactory, longer follow-ups are necessary to assess this cup long-term survivorship.


Subject(s)
Absorptiometry, Photon/methods , Acetabulum/diagnostic imaging , Arthroplasty, Replacement, Hip/methods , Hip Prosthesis , Osteoarthritis, Hip/surgery , Titanium , Adolescent , Adult , Aged , Bone Density , Bone Remodeling , Female , Follow-Up Studies , Humans , Male , Middle Aged , Osseointegration , Osteoarthritis, Hip/diagnosis , Porosity , Prospective Studies , Prosthesis Design , Quality of Life , Time Factors , Young Adult
3.
Joints ; 4(3): 159-164, 2016.
Article in English | MEDLINE | ID: mdl-27900308

ABSTRACT

Knee extensor mechanism rupture is a serious complication of total knee arthroplasty (TKA). Its prevalence ranges from 1 to 10% and it is commonly observed as a chronic multifactorial pathology with the patellar tendon as the most common site of rupture. Knee extensor mechanism reconstruction can be performed using allogenic or synthetic grafts. In the literature it is still not clear whether one of these techniques is superior to the other and the choice is usually tailored to the patient case by case. Allografts allow better restoration of the anatomical landmarks, whereas the mesh technique is more reproducible and the graft does not elongate over time. Allografts carry an increased risk of infection compared with synthetic reconstructions, while the mesh technique is cheaper and more readily available. In this paper, we review the etiology, diagnosis and treatment of this pathology, drawing on the most recent literature.

4.
Ann Transl Med ; 4(1): 2, 2016 Jan.
Article in English | MEDLINE | ID: mdl-26855938

ABSTRACT

The posterior cruciate ligament (PCL) conservation and the polyethylene insert constraint in total knee arthroplasty (TKA) are still debated. The PCL is one of the primary stabilizers of the joint, but cruciate retaining (CR) implants have the disadvantage of a difficult balancing of the PCL. Postero-stabilized (PS) implants were introduced to reduce this problem. However, also the PS implants have some disadvantages, due to the cam-mechanism, such as high risk of cam-mechanism polyethylene wear. To minimize the polyethylene wear of the cam-mechanism and the bone sacrifice due to the intercondylar box, different types of inserts were developed, trying to increase the implant conformity and to reduce stresses on the bone-implant interface. In this scenario ultra-congruent (UC) inserts were developed. Those inserts are characterized by a high anterior wall and a deep-dished plate. This conformation should guarantee a good stability without the posterior cam. Few studies on both kinematic and clinical outcomes of UC inserts are available. Clinical and radiological outcomes, as well as kinematic data are similar between UC mobile bearing (MB) and standard PS MB inserts at short to mid-term follow-up. In this manuscript biomechanics and clinical outcomes of UC inserts will be described, and they will be compared to standard PS or CR inserts.

5.
Joints ; 3(3): 151-7, 2015.
Article in English | MEDLINE | ID: mdl-26889472

ABSTRACT

Meniscal tears are commonly associated with anterior cruciate ligament (ACL) injuries. A deficient medial meniscus results in knee instability and could lead to higher stress forces on the ACL reconstruction. Comparison of results in meniscectomy and meniscal repairs revealed worse clinical outcomes in meniscectomy, but higher re-operation rates in meniscal repairs. Our aim was to review the results of ACL reconstruction associated with meniscectomy or meniscal repair.

6.
Knee Surg Sports Traumatol Arthrosc ; 22(8): 1786-92, 2014 Aug.
Article in English | MEDLINE | ID: mdl-24781274

ABSTRACT

PURPOSE: Mobile bearing (MB) knee prostheses were designed to improve the performances of the total knee arthroplasties (TKA). The clinical superiority of MB prosthesis compared to its fixed bearing counterpart has remained elusive. This study prospectively evaluates the cumulative survivorship, clinical, radiographic results, and complications of a large series of MB TKAs in relation to patient age, sex, severity of arthritis, and patellar resurfacing. METHODS: This study evaluates the 5- to 10-year cumulative survival rate of the NexGen(®) LPS MB. Between 2000 and 2005, we performed a consecutive series of 332 MB, posterior-stabilized TKA in 249 patients (mean age 71.2 years, SD 6.9). The implants were clinically evaluated with the Hospital Special Surgery Knee Score (HSS-KS) and radiographically with the Knee Society Roentgenographic Evaluation System (KS-RES). The mean follow-up was 76.3 months (minimum 5 years). RESULTS: The HSS-KS improved from 55 pre-operatively to 86 at the end of follow-up. According to the KS-RES, the implants were anatomically aligned and progressive radiolucent lines appeared in four knees (1.2 %). The patella was selectively resurfaced in 162 of 332 knees. Patients with the patella resurfaced had better clinical results compared to those not resurfaced, but there was no difference in terms of survival. The cumulative survival rate was 98.4 % at 10 years (Kaplan-Meier's analysis). CONCLUSIONS: This MB implant provided reliable and durable clinical results with a survivorship of over 98 % at 10 years, in unselected patients regardless of age, sex, severity of disease, and patellar treatment.


Subject(s)
Arthroplasty, Replacement, Knee , Knee Prosthesis , Aged , Female , Follow-Up Studies , Humans , Knee Joint/surgery , Male , Middle Aged , Range of Motion, Articular , Retrospective Studies
7.
J Bone Joint Surg Am ; 95(12): e83, 2013 Jun 19.
Article in English | MEDLINE | ID: mdl-23783214

ABSTRACT

BACKGROUND: The superiority of mobile-bearing total knee arthroplasty implants over fixed-bearing implants, or vice versa, is still debated. METHODS: A series of patients with similar clinical and radiographic characteristics were treated consecutively with 100 fixed-bearing followed by 100 rotating-platform implants. Patients underwent prospective clinical and radiographic evaluation. RESULTS: The mean duration of follow-up was 116 months (range, sixty-one to 144 months). Clinical, radiographic, and implant survival outcomes were compared. No significant differences between the mobile-bearing and fixed-bearing groups were found with respect to the clinical outcome or cumulative implant survival at the time of the latest follow-up. Three of the fixed-bearing implants and one of the rotating-platform implants had required revision surgery. CONCLUSIONS: No differences between mobile-bearing and fixed-bearing designs were demonstrated at a mean of 116 months of follow-up.


Subject(s)
Arthroplasty, Replacement, Knee/instrumentation , Knee Prosthesis , Adult , Aged , Aged, 80 and over , Arthritis, Rheumatoid/physiopathology , Arthritis, Rheumatoid/surgery , Arthroplasty, Replacement, Knee/methods , Female , Follow-Up Studies , Humans , Male , Middle Aged , Osteoarthritis, Knee/diagnostic imaging , Osteoarthritis, Knee/physiopathology , Osteoarthritis, Knee/surgery , Osteonecrosis/physiopathology , Osteonecrosis/surgery , Prospective Studies , Prosthesis Design , Radiography , Range of Motion, Articular/physiology , Treatment Outcome
8.
Case Rep Med ; 2011: 830296, 2011.
Article in English | MEDLINE | ID: mdl-21876701

ABSTRACT

This paper discusses a sciatic nerve palsy developed after a right total hip revision with a Burch-Schneider metal cage. A sciatalgic nerve pain appeared after surgery, while the palsy developed in about fifteen days. An electromyography showed the delay of the nerve impulse gluteal level. During the surgical exploration of the hip, a compression of the nerve on the metal cage was observed. The nerve was isolated, released from the fibrotic tissue and from the impingement, and was protected with a muscular flap. The recover from the pain was immediate, while the palsy recovered one month later.

9.
ISRN Orthop ; 2011: 290851, 2011.
Article in English | MEDLINE | ID: mdl-24977058

ABSTRACT

Infections in orthopaedic surgery are a serious issue. Antibiotic-loaded bone cement was developed for the treatment of infected joint arthroplasties and for prophylaxes in total joint replacement in selected cases. Despite the widespread use of the antibiotic-loaded bone cement in orthopedics, many issues are still unclear or controversial: bacterial adhesion and antibiotic resistance, modification of mechanical properties which follows the addition of the antibiotic, factors influencing the release of the antibiotic from the cement and the role of the surface, the method for mixing the cement and the antibiotic, the choice and the effectiveness of the antibiotic, the combination of two or more antibiotics, and the toxicity. This review discusses all these topics, focusing on properties, merits, and defects of the antibiotic loaded cement. The final objective is to provide the orthopaedic surgeons clear and concise information for the correct choice of cement in their clinical practice.

SELECTION OF CITATIONS
SEARCH DETAIL