1.
Egypt Heart J ; 76(1): 20, 2024 Feb 12.
Article in English | MEDLINE | ID: mdl-38345661

ABSTRACT

BACKGROUND: Transcatheter Aortic Valve Implantation (TAVI) has a growing target population after being indicated even in low-surgical-risk patients with severe symptomatic aortic stenosis. However, postoperative outcomes can be compromised due to para-valvular leakage (PVL). A lot of procedural steps have been investigated to decrease this partially avoidable operational hazard. Oversizing is a main technique to decrease the PVL, despite being itself a risky step. Many studies have been conducted to identify the optimum degree of oversizing. However, studies about oversizing by more than 20% are scarce. We aimed to evaluate the safety and efficacy of oversizing equal to or more than 20%. RESULTS: 209 patients who underwent TAVI using the self-expandable valve Evolut R were initially included. 66 patients were excluded because of the baseline conduction disturbance and lack of sufficient data, so 143 patients, 60 females and 83 males, were enrolled in our study as two groups based on the degree of oversizing: Group A included 97 patients with an oversizing index (OI) of less than 20%, and Group B included 46 patients with an OI of 20% or more. We conducted a new technique for more accurate measuring of the OI in the context of the implantation depth, and our patients were categorized using this technique. Our findings have met our primary end point in terms of the safety and efficacy of oversizing by 20% or more. There was no significant difference between both groups in terms of new-onset conduction disturbance (NOCD), with zero cases of annular rupture or coronary encroachment. In terms of efficacy, The incidence of significant PVL (grade 2 or more) in group B was less than in group A (P value 0.007). The ROC curve found that the minimum depth of implantation-derived oversizing (DIDO) to predict no significant PVL was less than 17%. CONCLUSION: Prosthesis oversizing by 20% using the self-expandable Evolut R valve is safe and effective, with no significant effect on the conduction system, coronary encroachment, or annular injury, and warrants a greater reduction in the incidence of significant PVL.

2.
J Saudi Heart Assoc ; 34(3): 148-152, 2022.
Article in English | MEDLINE | ID: mdl-36196374

ABSTRACT

Objectives: To evaluate the long-term outcome of patients who underwent percutaneous transcatheter closure of secundum atrial septal defects during teenage life versus adulthood. Methods: The study included 100 patients with secundum type ASD who were treated by transcatheter closure of their defects 2-5 years before enrollment. The study population was subdivided into 2 equal groups: group 1 who underwent transcatheter closure during teenage life (13-19 years) and group 2 who underwent transcatheter closure after the age of 30 years. The two groups were compared according to resting 12 lead ECG, 24-h Holter ECG and transthoracic echocardiographic findings (Right ventricular size and functions, right atrial size, etc.). Results: The study population showed female predominance. The average follow up period was similar in both groups. Adult patients had more frequent right bundle branch block morphology in their resting 12 lead ECG than teenagers (69% versus 45% respectively, p < 0.01). The incidence of arrhythmias encountered in Holter ECG was also significantly higher in the adult group. Premature atrial contractions (PAC) were present in 10 patients (20%) in adult group while 3 patients (6%) had PACs in teenagers' group with p < 0.01. The mean PAC burden was also higher in the adult group (9% versus 1.3%, p < 0.001). Paroxysmal AF lasting more than 30 seconds was found in 6 patients (12%) in the adult group while 1 patient in teenagers developed AF, p < 0.01. Regarding transthoracic echocardiography, adult patients showed significantly larger RV diameter, indexed RA area, indexed LA volume and more LV diastolic dysfunction. RV systolic functions were better in the teenage group as measured by 2D echocardiography. Adult patients with higher age, bigger defect size and device size had more abnormal ECG and echocardiographic findings. Conclusion: Early trans-catheter closure of secundum ASD during teenage life yields better right ventricular systolic function, better right ventricular size and less incidence of atrial arrhythmia.

3.
Egypt Heart J ; 73(1): 86, 2021 Oct 12.
Article in English | MEDLINE | ID: mdl-34637037

ABSTRACT

BACKGROUND: Ventricular septal defect (VSD) is the most common congenital heart disease. In patients with large VSD, left side chambers are subjected to volume overload with subsequent chambers dilatation and eccentric left ventricular hypertrophy. Percutaneous closure of VSD has been shown to be an effective method with equal safety and efficacy when compared to surgery. The effect of VSD closure on LV remodeling has been mainly assessed in patients treated with surgery and to date published data remain scarce. Therefore, we aim to evaluate the effect of percutaneous VSD closure on different LV parameters. RESULTS: Seventeen patients (median age 6 years (IQR 4.75-8 years), 70.6% females) who underwent percutaneous VSD closure were enrolled in the study. Sixteen patients (94%) had perimembranous VSD, and one patient had muscular VSD. The procedure was successful in all patients with no major complications. Nit Occlud® Lê coil device was implanted in 16 patients (94%), and one patient received Amplatzer PDA duct occlude device. At 6-months follow-up, there was a significant reduction in indexed LV dimensions [LVEDD/BSA (median 46.5 mm/m2 vs. 42.9 mm/m2, p = 0.03), LVESD/BSA (median 31.7 mm/m2 vs. 26.7 mm/m2, p = 0.02)], indexed LV volumes [LVEDV/BSA (median 52.6 ml/m2 vs. 37.3 ml/m2, p = 0.02), LVESV/BSA (median 31.7 ml/m2 vs. 23.3 ml/m2, p = 0.02)] and indexed LV mass (median 62.4 gm/m2 vs. 57.9 ml/m2, p = 0.01). There was a significant reduction in LVEDD Z-score (p = 0.01) and LVESD Z-score (p = 0.04). There was no significant change in LV EF. CONCLUSIONS: Percutaneous VSD closure is associated with improvement of various LV parameters with consequential favorable LV remodeling and function.

4.
Eur Heart J ; 41(20): 1874-1875, 2020 05 21.
Article in English | MEDLINE | ID: mdl-32438405
5.
Egypt Heart J ; 72(1): 1, 2019 Dec 31.
Article in English | MEDLINE | ID: mdl-31893314

ABSTRACT

BACKGROUND: Proper device size selection is a crucial step for successful ASD device closure. The current gold standard for device size selection is balloon sizing. Balloon sizing can be tedious, time consuming and increase fluoroscopy and procedure times as well as risk of complications. We aimed to establish a simple and accurate method for device size selection using three-dimensional echocardiographic interrogation of the ASD.This is a prospective observational study conducted over a period of 12 months. All patients underwent 2D TTE, three-dimensional echocardiographic assessment of the IAS and transesophageal echocardiogram. Comparison between echocardiographic variables was done using independent sample t test. Linear correlation was established between three dimensional echocardiographic variables and respective variables of device size and 2D TTE and TEE measurements. RESULTS: The study included 50 patients who underwent successful ASD device closure with properly sized device. There was no significant difference between 3D ASD maximum diameter and all diameters measured by TTE and TEE. There was a strong positive correlation between device size used for closure and both 3D measured ASD area (r = 0.907, P<0.0001) and 3D measured ASD circumference (r = 0.917, P<0.0001). Two regression equations were generated to determine proper device size where Device size = 10.8 + [3.95 x 3D ASD area] and Device size = [3.85 x 3D ASD circumference] -1.02 CONCLUSION: Three-dimensional echocardiogram can provide a simple and accurate method for device size selection in patients undergoing ASD device closure using either 3D derived ASD area or ASD circumference.

6.
Eur Heart J Cardiovasc Imaging ; 17(3): 316-25, 2016 Mar.
Article in English | MEDLINE | ID: mdl-26113121

ABSTRACT

AIM: To assess the effect of balloon mitral valvuloplasty (BMV) on global and regional ventricular functions using 2D strain. METHODS AND RESULTS: Thirty-two patients with mitral stenosis (MS) and 30 healthy subjects underwent full echocardiographic examinations, including left ventricle (LV) and right ventricle (RV) regional and global longitudinal strain (GLS) measurements. In MS patients, measurements were repeated within 24 h and 3 months after BMV. Patients with MS had lower LV and RV GLS compared with control group (-16.5 ± 2.7% vs. -21.0 ± 1.5) and (-18.3 ± 4.7 vs. -19.8 ± 1.3), respectively. Significant decrease was noted in the basal and septal segments compared with the apical LV segments and RV free wall. BMV resulted in significant improvement in LV and RV GLS within 24 h post-BMV compared with baseline values (P = 0.0001 and 0.0002, respectively), an improvement which was maintained after 3 months. There was significant positive correlation between both LV and RV GLS at baseline and mitral valve mean pressure gradient and RV systolic pressure and significant inverse correlation between LV GLS and MVA. CONCLUSION: MS patients have subclinical LV and RV systolic dysfunction by GLS despite normal ejection fraction and fractional area change. BMV results in marked improvement in LV and RV GLS immediately post-BMV with trend towards normalization at follow-up after 3 months. A mixed aetiology theory involving a myocardial as well as a haemodynamic factor is believed to be the cause for this subclinical biventricular dysfunction and its improvement at short-term follow-up post-BMV.


Subject(s)
Balloon Valvuloplasty , Echocardiography , Mitral Valve Stenosis/diagnostic imaging , Mitral Valve Stenosis/therapy , Ventricular Function/physiology , Adolescent , Adult , Case-Control Studies , Female , Hemodynamics , Humans , Male , Prospective Studies , Treatment Outcome
7.
J Heart Valve Dis ; 22(2): 265-9, 2013 Mar.
Article in English | MEDLINE | ID: mdl-23798220

ABSTRACT

Balloon valvuloplasty to dilate stenotic bioprosthetic valves is rarely used, but has been applied successfully to dilate bioprosthetic mitral, aortic, tricuspid and, to a lesser extent, pulmonary valves. The case is reported of a 45-year-old male patient with right-sided heart failure who underwent a successful dilatation of a stenotic, calcific bioprosthetic pulmonary valve using double-balloon valvuloplasty.


Subject(s)
Balloon Valvuloplasty , Bioprosthesis , Calcinosis/therapy , Graft Occlusion, Vascular/therapy , Heart Valve Prosthesis , Pulmonary Valve , Humans , Male , Middle Aged , Time Factors
8.
Pediatr Cardiol ; 33(1): 27-35, 2012 Jan.
Article in English | MEDLINE | ID: mdl-21811814

ABSTRACT

Cardiac catheterizations are among the X-ray procedures with the highest patient radiation dose and therefore are of great concern in pediatric settings. This study aimed to evaluate factors that influence variability of X-ray exposure in children with congenital heart diseases during cardiac catheterization. The study included 107 children who underwent either diagnostic (n = 46) or interventional (n = 61) procedures. A custom-made sheet for patient and procedural characteristics was designed. Data were collected, and different correlations were applied to determine factors that influence variability of X-ray exposure. The fluoroscopy time (FT) differed significantly between the diagnostic (8.9 ± 6.3 min) and intervention (12.8 ± 9.98 min) groups (P = 0.032). The mean dose-area product (DAP) differed significantly between the two groups (3.775 ± 2.5 Gy/cm(2) vs. 13.239 ± 15.4 Gy/cm(2); P = 0.003). The highest DAP was during left anterior oblique (LAO) cranial 30° angulation (2.8 Gy/cm(2)/4 s cine). The mean cumulative dose (CD) was 0.053 Gy in diagnostic cases and 0.48 Gy in intervention cases. The effective dose was 5.97 ± 7.05 mSv for therapeutic procedures compared with 3.42 ± 3.64 mSv for diagnostic procedures. The FT correlated significantly with both the DAP (r = 0.718; P < 0.001) and the CD (r = 0.701; P < 0.001). Other correlations were reported. An increasing number of therapeutic catheterization procedures are being performed for children. The justification for these procedures is evident because they avoid complicated surgery. However, the complexity of these procedures results in higher radiation exposures.


Subject(s)
Cardiac Catheterization/adverse effects , Fluoroscopy/adverse effects , Heart Defects, Congenital/diagnostic imaging , Adolescent , Child , Child, Preschool , Female , Heart Defects, Congenital/surgery , Humans , Infant , Male , Radiation Dosage , Radiometry , Young Adult
9.
Echocardiography ; 29(2): 173-81, 2012 Feb.
Article in English | MEDLINE | ID: mdl-22044613

ABSTRACT

PURPOSE: To assess left ventricular mechanical dyssynchrony (LVMD) using real time three-dimensional echocardiography (RT3DE) and comparing it with the different dyssynchrony indices derived from Doppler tissue imaging (DTI) for the same patient. METHODS: The study included 60 consecutive patients who were considered candidates for CRT, i.e., having ejection fraction ≤35%, NYHA class III or ambulatory class IV, QRS duration ≥120 msec, on optimal pharmacological therapy. Apical RT3DE full volumes were obtained and analyzed to generate the systolic dyssynchrony index (SDI-16), which is the standard deviation of the time to minimal systolic volume of the 16 segments of LV. Color-coded DTI was performed for the three standard apical views with estimation of the mechanical dyssynchrony index (12 Ts-SD), which is the standard deviation of the time to peak systolic velocity at 12 segments of LV. RESULTS: SDI-16 was 10.96 ± 3.9% (cutoff value: 8.3%), while Ts-SD was 38 ± 10.2 msec (cutoff value: 32.6 msec). The concordance rate for both indices was 75%; however, there was no correlation between both indices (r = 0.14, P = 0.3). SDI-16 showed good correlation with QRS duration (r = 0.45, P < 0.001) and inverse correlation with left ventricular ejection fraction (LVEF) calculated by RT3DE (r =-0.37, P = 0.004), while 12 Ts-SD index showed no correlation with QRS duration (r =-0.0082, P = 0.51) or 2D LVEF (r =-0.26, P = 0.84). CONCLUSIONS: RT3DE can quantify LVMD by providing the SDI-16 and it may prove to be more useful than DTI as it shows increasing dyssynchrony with increased QRS duration and decreased LVEF.


Subject(s)
Echocardiography, Doppler/methods , Echocardiography, Three-Dimensional/methods , Ventricular Dysfunction, Left/diagnostic imaging , Analysis of Variance , Echocardiography, Doppler, Color/methods , Female , Humans , Male , Middle Aged , Sensitivity and Specificity